Publication 1394-5.13 - September 1998
Installation Instructions
Installing Your 1394-CPDCP Power Plug
This document illustrates the installation of the 1394-CPDCP and is
used in conjunction with the 1394 Digital AC Multi-Axis Motion
Control System User Manual (publication 1394-5.0). Use the 1394-
CPDCP to terminate the 1394-DCLM which provides additional
capacitance for the 1394 system.
Installing the Power Plug To install the power plug:
1. Locate the DC link power connector on the front underside of the
1394-DCLM.
Figure 1
Locating the DC Link Power Connector
2. Install the power plug to the DC link power connector using the
provided screws (4M x 10) with 12-15in./lbs of torque.
Figure 2
Installing the Power Plug
DC Link Power Connector
Power Plug
DC Link
Module
1394 Digital Servo Controller
System Module
Allen-Bradley
Screws
Publication 1394-5.13 - September 1998 191840
Copyright 1998 Allen-Bradley Company, Inc. Printed in USA
For more information refer to our web site: www.ab.com/motion
For Rockwell Automation Technical Support information refer to: www.rockwellautomation.com/support or Tel: (1) 440.646.3434