Davey RainBank mkII Installation Instructions Manual

Davey RainBank mkII Installation Instructions Manual

Davey RainBank mkII is a water controller that helps you save water and money by automatically switching between rainwater and mains water. It can save up to 40% of your home's usage of mains water, which could be up to 100,000 litres of water a year. RainBank mkII is energy efficient and cheap to run, using the equivalent daily power of a reverse cycle air conditioner for 3 minutes or a washing machine for 10 minutes. It has an in-built "dual check valve" for low hazard back flow prevention and is easy to install, with two types of installation - above ground or in-tank.

advertisement

For any assistance or after sales service contact your Davey
Dealer. For help in locating your closest dealer contact your
appropriate Davey Support Centre listed on the
back of this booklet.
• InstallatIon
operatIon
trouble shootIng
InstallatIon
InstructIons
3
Y
E
A
R
S
G
U
A
R
A
N
T
E
E
O
N
A
L
L
R
A
I
N
B
A
N K
S
3YEARS
MKII
2009 WINNER
ATS 5200.446 Lic WMKA 22042
AUSTRALIA
Davey Support Centre
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 367 866
Fax: 1300 369 119
Website: davey.com.auDavey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NEW ZEALAND
Davey Support Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 09 527 7654
Website: daveynz.co.nz
® Davey and RainBank are registered trade marks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2013. P/N 401336-11 supersedes P/N 401336-10
2 35
Davey commenced in 1934 and today, as Davey Water products, manufactures and distributes a
comprehensive range of products for transfer, conservation, treatment and filtration of water.
Davey has a dominant market share in australia and exports to more than 50 separate countries,
servicing some of the toughest environmental and climatic conditions on the globe.
Davey has maintained its commitment to research and development, resulting in innovative new
products servicing specific and emerging market opportunities. Many of these products have received
multiple awards for innovation and excellence which have led to our induction into the Manufacturing
h
all of Fame in Victoria.
Davey maintains leadership in quality with an environmental focus by holding Iso 9000-2001
accreditation and Iso 14000 environmental standard.
Davey is today a wholly owned subsidiary of guD, a ‘top 200’ australian public company whose shares
are listed on the australian stock exchange.
n
ow more than ever “Depend on Davey” reflects a business culture of dependable, innovative water
solutions when and where you need them, supported by the best service and advice.
DaVeY guarantee
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
Davey® Repair or Replacement Guarantee
In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty
periods beginning from the date of original purchase due to faulty materials or manufacture, Davey will at our option
repair or replace it for you free of charge, subject to the conditions below.
Should you experience any difficulties with your Davey product, we suggest in the first instance that you contact
the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our Customer Service
line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address
listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or
defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.
Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product consumables (i.e.
mechanical seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, improper
use for which the product was not designed or advertised, failure to properly follow the provided installation and
operating instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, lightning or high
voltage spikes, or unauthorized persons attempting repairs. Where applicable, your Davey product must only be
connected to the voltage shown on the nameplate.
Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please retain your
receipt as proof of purchase; you MUST provide evidence of the date of original purchase when claiming under the
Davey Guarantee.
Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of
any kind whatsoever arising directly or indirectly from Davey products. This limitation does not apply to any liability
of Davey for failure to comply with a consumer guarantee applicable to your Davey product under the Australian
or New Zealand legislation and does not affect any rights or remedies that may be available to you under the
Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure.
Should your Davey product require repair or service after the guarantee period; contact your nearest Davey Dealer
or phone the Davey Customer Service Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:
Davey Guarantee Period
RainBank Controller - Three Years Pump - Two Years
34 3
contents

a
bout rainbank® . the easy way to save water. 4
t
wo types of installation - quick reference 5
h
ow rainbank® works 6
h
ow to install rainbank® 7
b
efore you start 9
Installation instruction 11
p
ump outside tank option 12
p
ump inside tank option 14
Float switch installation 18
Installation of submersible pumps 25
p
riming pumps 26
Maintaining rainbank® 28
t
rouble shooting rainbank® 29
Warnings 32
p
lumbers tips 33
Davey guarantee 35
c
ontact Details 36
n
otes
m5 m
5
m4
100,000 Litres
4 33
c
ongratulations on your purchase of
a high quality australian made Davey
r
ainbank® automatic water controller.
r
ainbank® is patented and has been fitted
to thousands of homes.
rainbank® allows you to use water
from your rainwater tank for your
toilet, washing machine or garden
whenever there is water in the tank.
If the tank water is exhausted
r
ainbank® automatically and
seamlessly switches you over to mains
water.
rainbank® has an in-built “dual
check valve” for low hazard back flow
prevention.
RainBank® can save up to 40% of
your home’s usage of mains water,
which could be up to 100,000 litres
of water a year.
Your actual savings depend on your roof
catchment area, rainfall and the size of
your tank.
RainBank® may allow you to claim
tank rebates (when installed on
existing homes). Check with your
local water authority.
In some areas of australia, having a
r
ainbank® and using rainwater for
your toilet and washing machine allows
you to claim tank rebates paid by state
governments and some councils.
RainBank® is energy efficient and
cheap to run.
b
ecause rainbank® only works when it is
needed it uses very little energy.
t
he daily power used to run a rainbank®
and pump system supplying two toilets in
a three person dwelling is equivalent to:
a reverse cycle air conditioner for
3 minutes
a clothes dryer for 3 minutes
a washing machine for 10 minutes
a tV or pc for 30 minutes
a
bout raInbank®
t
he easY WaY to saVe Water pluMbers tIps
1. Install pump on a level, solid, well drained site (this will reduce noise and pipe
stress).
2. Fit first flush devices to all down pipes to ensure clean water inside the tank (dirty
tank water can stain toilets & clothes).
3. clear swarf from all pipes and holes drilled into the tank (swarf can block valves,
r
ainbank® and toilet valves). Fit a 200 micron ‘Y’ strainer before the pump or
between the pump and rainbank.
4. Fit a stop valve on mains water line before rainbank (makes servicing easier).
5. Fit a stop valve between pump and tank outlet (makes servicing easier).
6. check with local council plumbing teams for backflow requirements.
7. keep pipe work well braced as vibrations can become noisy.
8. Fill rainwater tank above float switch with garden hose to check system.
9. Make sure pump is full of water (primed) before leaving site. Flush all air outof
system by running pump with an outlet downstream open.
p
rotect from the weather Don’t create air locks!
Fit isolation valves prime pump before switching on
5
6
7
8
9
10
11
12
13
14
15
16
17
18
  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
/

advertisement

Related manuals

advertisement