1 About this manual
Read all the documentation supplied carefully before installing and using this product. Keep the manual in a convenient place for future reference.
1.1 Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the power supply before proceeding with any operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the system to function properly. Please read the procedure described very carefully and carry it out as instructed.
INFO
Description of system specifications.
We recommend reading this part carefully in order to understand the subsequent stages.
2 Notes on copyright and information on trademarks
The mentioned names of products or companies are trademarks or registered trademarks.
3 Safety rules
CAUTION! Device installation and maintaining must be performed by specialist technical staff only.
• CAUTION! The electrical system to which the unit is connected must be equipped with an automatic bipolar circuit breaker. The circuit breaker for main supply voltage phase units must have a level of intervention of 20A max. The circuit breaker for low voltage units must have a level of intervention of
6A max. This circuit breaker must be of the Listed type. The minimum distance between the circuit breaker contacts must be 3mm (0.1in). The circuit breaker must be provided with protection against the fault current towards the ground (differential) and the overcurrent (magnetothermal).
• The manufacturer declines all responsibility for any damage caused by an improper use of the appliances mentioned in this manual.
Furthermore, the manufacturer reserves the right to modify its contents without any prior notice.
The documentation contained in this manual has been collected and verified with great care. The manufacturer, however, cannot take any liability for its use. The same thing can be said for any person or company involved in the creation and production of this manual.
• Before starting any operation, make sure the power supply is disconnected.
• Be careful not to use cables that seem worn or old.
• Never, under any circumstances, make any changes or connections that are not shown in this handbook. Improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
• Use only original spare parts. Non-original spare parts could cause fire, electrical discharge or other hazards.
MNVCHPVB_2024_EN 5
• Comply with all the national standards during the device installation.
• This device was designed to be permanently secured and connected on a building or on a suitable structure. The device must be permanently secured and connected before any operation.
• Before proceeding with installation, check the supplied material to make sure it corresponds to the order specification by examining the identification labels (4.2 Product marking, page 7).
• Any device which could be installed inside the product must comply with the current safety standards.
• If the installation is NEMA TYPE 4X, the installer must replace the cable glands of the product with
NEMA TYPE 4X cable glands.
• For all connections, use cables that are able to withstand temperatures of at least 75°C (167°F).
• The product is designed to house only cameras that are properly certified according to IEC/UL
60950-1 or IEC/UL 62368-1 (7W max).
• A power disconnect device must be included in the electrical installation, and it must be very quickly recognizable and operated if needed.
• To connect the power supply line use the appropriate junction-box (UPTJBUL). For further information, refer to the product use and installation manual.
• Use Listed tube crimping lugs for the connection of the network conductors to the terminals. The copper tube crimping lugs must be suitable for the type of installation (from -20°C (-4°F) a +80°C
(+176°F) min., V-0). Copper tube crimping lugs examples: RP, BP o YP (Cembre).
• Installation category (also called Overvoltage
Category) specifies the level of mains voltage surges that the equipment will be subjected to.
The category depends upon the location of the equipment, and on any surge voltage protection provided. Equipment in an industrial environment, directly connected to major feeders/short branch circuits, is subjected to Installation Category
III. If this is the case, a reduction to Installation
Category II is required. This can be achieved by use of an insulating transformer with an earthed screen between primary and secondary windings, or by fitting UL listed Surge Protective Devices
(SPDs) from live to neutral and from neutral to earth. Listed SPDs shall be designed for repeated limiting of transient voltage surges and the following rated operation conditions: Type 2 (SPDs permanently connected to the power network and intended for installation on the load side of the service equipment); Nominal Discharge Current
(In) 20kA min. For example: FERRAZ SHAWMUT,
STT2240SPG-CN, STT2BL240SPG-CN rated
120Vac/240Vac, (In=20kA). Maximum distance between installation and reduction is 5m.
6 MNVCHPVB_2024_EN
4 Identification
4.1 Product description and type designation
4.1.1 VERSO
Sturdy, tamper-proof housing designed to simplify installation and service and guarantee total protection against all environmental conditions.
Its dimensions make it suitable for a variety of combinations of cameras and lenses.
Entirely constructed from technopolymer, it guarantees high impact resistance and perfect weather protection from external agents and UV rays.
Very easy to install thanks to the side-opening system that allows the full access to the camera, lenses and all internal connections.
The housing proposes various mounting options, wall or ceiling brackets, feedthrough and nonfeedthrough, or Pan & Tilt head.
4.1.2 VERSO COMPACT
Entirely constructed from technopolymer, it guarantees high impact resistance and perfect weather protection from external agents and UV rays.
4.1.3 VERSO POLAR
This housing is provided with a high performance heating system which it will continue working at even the most severe temperatures, right down to-
55°C (-67°F).
4.2 Product marking
See the label attached to the product.
MNVCHPVB_2024_EN 7
8
5 Preparing the product for use
Any change that is not expressly approved by the manufacturer will invalidate the guarantee.
5.1 Unpacking
When the product is delivered, make sure that the package is intact and that there are no signs that it has been dropped or scratched.
If there are obvious signs of damage, contact the supplier immediately.
When returning a faulty product we recommend using the original packaging for shipping.
Keep the packaging in case you need to send the product for repairs.
5.2 Contents
Check the contents to make sure they correspond with the list of materials as below:
• Housing
• Housing equipment:
• Allen wrench
• Spacers
• Cable glands gaskets
• Cable glands (x3)
• Bolts and screws
• Screws for camera
• Instruction manual
5.3 Safely disposing of packaging material
The packaging material can all be recycled. The installer technician will be responsible for separating the material for disposal, and in any case for compliance with the legislation in force where the device is to be used.
5.4 Preparatory work before installation
5.4.1 Mounting the bracket
The product must be fastened with suitable equipment. The fastening means must guarantee mechanical sealing when a force equal to at least 4 times the weight of the device is applied.
MNVCHPVB_2024_EN
6 Installation
6.1 Housing opening
Loosen the 2 screws on the side, turn the cover and the upper half of the body about the opening hinge axis.
6.2 How to install the camera
Open the housing as described in the relative chapter
(6.1 Housing opening, page 9).
Partially loosening the fastening screws (01).
Remove the internal slide (02) by sliding it until the holes coincide with the slide fastening screws.
Fasten the camera with the 1/4" screw (03). To position the camera and lens correctly, if necessary, use the supplied spacers. (04).
04
02
Fig.
1
After installation and wiring, close the product.
01 03
Fig.
2
Reposition the internal slide and tighten the screws that had been loosened previously.
Remove the conductors protective sheathing and connect them to terminal (camera power supply, 6.3
Board description, page 10).
The camera’s power supply cable conductors must be tied up with a cable tie next to the terminal. Keep the signalling and power supply cables separated from each other.
MNVCHPVB_2024_EN 9
6.3 Board description
Connect the safety earth to the relative terminal of the power supply connector.
The board may appear different to that illustrated.
Depending on the product version, the board may not be equipped with all functions.
J4
J5
J2
J3
BOARD DESCRIPTION (VERSO, VERSO COMPACT)
Connector Function
J1 Camera power supply (V
Tamper switch contacts2
OUT
)1
J6
SW1
Heater power supply (V
Auxiliary output (V
OUT
)4
OUT
)
Power supply for the board (V
IN
)3
Power supply connector/jumper5
Fan power supply (V
Tamper switch2
OUT
)
Tab.
1
1
Different alternatives are available depending on the version. V
OUT
= 12Vdc o V
OUT
= 24Vac, in relation to the type of power supply installed (7.2.1 Camera power supply installation, page 13). V
OUT
= V
IN
, only for housings powered in 12Vdc or 24Vac, with jumper inserted
(J5).
2
3
4
Optional. Only available for VERSO housing.
From 100Vac a 240Vac, 24Vac o12Vdc.
Same voltage applied to power supply terminal of the board (J3).
5
To install a power supply in 12Vdc or 24Vac refer to the relative chapter (7.2.1 Camera power supply installation, page 13).
J4 J3
Fig.
3
VERSO.
J2
J2
J1
Fig.
4
J4 J3 J1
VERSO COMPACT.
J6
J5
J6 SW1
J5
10 MNVCHPVB_2024_EN
BOARD DESCRIPTION (VERSO, VERSION WITH DOUBLE FILTER FOR
AIR RENEWAL)
Connector Function
J5
J7
J8
SW1
J3
J4
J1
J2
Power supply for the board (V
Auxiliary output (V
Tamper switch3
OUT
)2
Heater power supply (V
OUT
Tamper switch contacts3
Camera power supply (V
)
OUT
)4
IN
)1
Power supply connector/jumper5
Fan power supply (V
OUT
)
Tab.
2
1
From 100Vac a 240Vac, 24Vac o12Vdc.
2
Same voltage applied to power supply terminal of the board (J1).
3
Optional.
4
Different alternatives are available depending on the version. V
OUT
= 12Vdc o V
OUT
= 24Vac, in relation to the type of power supply installed (7.2.1 Camera power supply installation, page 13). V
OUT
= V
IN
, only for housings powered in 12Vdc or 24Vac, with jumper inserted
(J7).
5
To install a power supply in 12Vdc or 24Vac refer to the relative chapter (7.2.1 Camera power supply installation, page 13).
J8 J2 J1 J4
BOARD DESCRIPTION (VERSO POLAR)
Connector Function
J7
J8
J1, J2, J3
J6
J10
Heater power supply (V
Camera power supply (V
OUT
)4
OUT
OUT
)
)1
Power supply for the board (V
IN
)2
Power supply connector/jumper3
Auxiliary output (V
Tab.
3
1
Different alternatives are available depending on the version. V
OUT
= 12Vdc o V
OUT
= 24Vac, in relation to the type of power supply installed (7.2.1 Camera power supply installation, page 13). V
OUT
= V
IN
, only for housings powered in 12Vdc or 24Vac, with jumper inserted
(J8).
2
From 100Vac a 240Vac, 24Vac o12Vdc.
3
To install a power supply in 12Vdc or 24Vac refer to the relative chapter (7.2.1 Camera power supply installation, page 13).
4
Same voltage applied to power supply terminal of the board (J7).
J6 J3 J8
Fig.
6
J10 J7 J1 J2
VERSO POLAR.
Fig.
5
SW1 J7 J3 J5
VERSO (version with double filter for air renewal).
MNVCHPVB_2024_EN 11
6.4 Connection of the power supply line
Earth cable should be about 10mm longer than the other two, so that it will not be disconnected accidentally if pulled.
Insert the cables inside the housing using the cable glands. The cable glands are suitable for conductors with diameters of between 5mm and 10mm. The section of the cable inside the housing must be sufficiently long to allow connection. Suitably lock the cable glands.
Remove the conductors protective sheathing and connect them to terminal (Power supply for the
board, 6.3 Board description, page 10).
6.4.1 Type of cable
The cable used for the connection to the power supply line must be suitable for the intended use.
Comply with the current national standards on electrical installations.
6.5 Installation of the version with double filter for air renewal
During installation pay attention to the orientation of the air inlet filter fins.
Fig.
7
Depending on the angle of inclination of the housing, the orientation of the filter fins must prevent water penetrating in case of rain:
To guarantee weatherproof protection, install the housing on the support following the inclination limits as shown in the picture.
0˚
45°
45°
Fig.
8
Maximum tilt of the transversal axis: 0°.
Maximum tilt of the longitudinal axis: ±45°.
6.6 Desiccant bag
Take the dessicant salt bag out of its pack and insert it into the product.
12 MNVCHPVB_2024_EN
7 Accessories
For further details on configuration and use, refer to the relative manual.
7.1 Heater
7.1.1 Heater installation
Open the housing as described in the relative chapter
(6.1 Housing opening, page 9).
Fix the heater kit to the prearranged points on the body of the housing.
The pre-wired heating element (01) should be positioned between the 2 dissipators (02) before attachment to ensure contact and hence guarantee correct heat transmission.
7.2 Camera power supply
7.2.1 Camera power supply installation
Pay attention to the voltage used to power the circuit. Depending on requirements use the correct power supply kit.
Usable power supplies:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
01
02
02
Fig.
11
Camera power supply.
Open the housing as described in the relative chapter
(6.1 Housing opening, page 9).
Position the camera power supply in the provided seating, parallel to the support ribs. Fix the power supply to the body of the housing using the corner bracket and screws supplied in the camera power supply kit.
Fig.
9
Pass the heating wiring into the provided seatings.
Fig.
12
Fig.
10
Reposition the internal slide and tighten the screws that had been loosened previously.
MNVCHPVB_2024_EN 13
At the end of istallation, connect the wiring to
the terminal (power supply connector, 6.3 Board description, page 10).
Fig.
13
7.3 Blower
7.3.1 Blower installation
Not usable in versions with double filter for air renewal.
Pay attention to the voltage used to power the circuit. Depending on requirements use the correct power supply kit.
The blower kit should be assembled according to the instructions to ensure a correct air circulation inside the housing.
Open the housing as described in the relative chapter
(6.1 Housing opening, page 9).
Fix the blower using the corner bracket and screws.
The VERSO housing is provided with a single installation location for the blower (01). In VERSO
COMPACT housing you can choose between two different installation locations (02).
01
8 Cleaning
8.1 Cleaning the window and plastic parts
Avoid ethyl alcohol, solvents, hydrogenated hydrocarbide, strong acid and alkali. Such products may irreparably damage the surface.
We recommend using a soft cloth with neutral soap diluted with water or specific products to clean the glasses lenses.
9 Information on disposal and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates that these devices should not be disposed of in the normal flow of municipal solid waste, but they should be collected separately in order to optimize the recovery stream and recycling of the materials that they contain and to reduce the impact on human health and the environment due to the presence of potentially hazardous substances.
The symbol of the crossed out bin is marked on all products to remember this.
The waste may be delivered to appropriate collection centers, or may be delivered free of charge to the distributor where you purchased the equipment at the time of purchase of a new equivalent or without obligation to a new purchase for equipment with size smaller than 25cm (9.8in).
For more information on proper disposal of these devices, you can contact the responsible public service.
02
Fig.
14
14 MNVCHPVB_2024_EN
10 Technical data
10.1 VERSO
10.1.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.1.2 Mechanical
Internal usable area (WxH): 70x70mm (2.7x2.7in)
Internal usable length (with or without accessories):
270mm (10.6in)
Cable glands: 3xM16
Polycarbonate window (WxH): 105x64mm (4.1x2.5in)
Unit weight: 1.5kg (3.3lb)
10.1.3 Electrical
Supply voltage/Current consumption (empty version):
• From 12Vdc up to 24Vdc, 1A max
• From 12Vac up to 24Vac, 1A max, 50/60Hz
• From 120Vac up to 230Vac, 400mA max, 50/60Hz
Supply voltage/Current consumption (version with heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Supply voltage/Current consumption (version with heater fan assistant, continuous duty):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
• From 100Vac up to 240Vac, 40mA max,
50/60Hz (with wide-range power supply)
Supply voltage/Current consumption (version with blower and thermostat for models with double filter for air renewal, Ton 35°C±3°C (95°F±5°F), Toff
20°C±3°C (71°F±5°F)):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.1.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): From -20°C
(-4°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids, oils
• Low resistance: Solvents
10.1.5 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66/IP67 (with cable glands)
• IP66/IP67 (with bracket with internal cable channel, with sealing rings)
• IP55 (with bracket with internal cable channel)
• IP44 (for models with a double filter for air renewal)
IK protection degree (EN62262): IK10
UL certification:
• cULus Listed, TYPE 4X (except for versions with double filter for the air exchange)
• UL94, V1 (fire-self extinguish)
EAC certification
MNVCHPVB_2024_EN 15
10.2 VERSO COMPACT
10.2.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.2.2 Mechanical
Internal usable area (WxH): 63x63mm (2.5x2.5in)
Internal usable length (with or without accessories):
210mm (8.3in)
Cable glands: 2xM16
Polycarbonate window (WxH): 98x55mm (3.9x2.2in)
Unit weight: 1.1kg (2.2lb)
10.2.3 Electrical
Supply voltage/Current consumption (empty version):
• From 12Vdc up to 24Vdc, 1A max
• From 12Vac up to 24Vac, 1A max, 50/60Hz
• From 120Vac up to 230Vac, 400mA max, 50/60Hz
Supply voltage/Current consumption (version with heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Supply voltage/Current consumption (version with heater fan assistant, continuous duty):
• 12Vdc, 400mA max
• 24Vac, 200mA max, 50/60Hz
• From 100Vac up to 240Vac, 40mA max,
50/60Hz (with wide-range power supply)
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.2.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): from -20°C
(-4°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids, oils
• Low resistance: Solvents
10.2.5 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66 (with cable glands)
• IP66 (with bracket with internal cable channel, with sealing rings)
IK protection degree: EN62262, IK10
UL certification:
• cULus Listed, TYPE 4X
• UL94, V1 (fire-self extinguish)
EAC certification
16 MNVCHPVB_2024_EN
10.3 VERSO POLAR
10.3.1 General
Made of strong technopolymer (polycarbonate)
Sunshield in ABS
RAL9002 Colour
Stainless steel external screws
10.3.2 Mechanical
Internal usable area (WxH): 70x70mm (2.7x2.7in)
Internal usable length (with or without accessories):
270mm (10.6in)
Cable glands: 3xM16 (nickel-plated brass for external connections)
Polycarbonate window (WxH): 105x64mm (4.1x2.5in)
Unit weight: 1.5kg (3.3lb)
10.3.3 Electrical
Supply voltage/Current consumption (version with heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C
(72°F±5°F)):
• From 12Vdc up to 24Vdc, 5A max
• From 12Vac up to 24Vac, 5A max, 50/60Hz
• From 120Vac up to 230Vac, 700mA max, 50/60Hz
Camera power supply:
• IN from 100Vac up to 240Vac, 50/60Hz - OUT
12Vdc, 1.25A
• IN 230Vac, 50Hz - OUT 24Vac, 50Hz, 400mA
10.3.4 Environment
For indoors and outdoors installation
Operating temperature (with heater): From -55°C
(-67°F) up to +60°C (140°F)
Chemical agents resistance
• High resistance: basics, alcohols, gas, hydrocarbon
• Good resistance: Organic acids, inorganic acids, oils
• Low resistance: Solvents
10.3.5 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1
Electromagnetic compatibility (CE): EN50130-4,
EN61000-6-3, EN55032 Class B, FCC Part. 15 Class B,
ICES-003 Class B
Outdoor installation (CE): EN60950-22, IEC 60950-22
IP protection degree (EN60529):
• IP66 (with cable glands)
• IP66 (with bracket with internal cable channel, with sealing rings)
• IP55 (with bracket with internal cable channel)
IK protection degree: EN62262, IK10
UL certification:
• cULus Listed, TYPE 4X
• UL94, V1 (fire-self extinguish)
EAC certification
MNVCHPVB_2024_EN 17
11 Technical drawings
The indicated measurements are expressed in millimetres.
B
270
USABLE AREA
A - A
466
70
USABLE
AREA
B - B
A
B
70
77
100
171
40 73
156
A
26
Fig.
15
VERSO.
210
USABLE AREA
A - A
400
B
B
Fig.
16
VERSO COMPACT.
94
63
USABLE
AREA
B - B
A
135
A
15
18 MNVCHPVB_2024_EN
B
270
USABLE AREA
A - A
466
B
70 171
40 73
70
USABLE
AREA
B - B
A
156
A
Fig.
17
VERSO POLAR.
MNVCHPVB_2024_EN 19
Headquarters Italy
Videotec S.p.A.
Via Friuli, 6 - I-36015 Schio (VI) - Italy
Tel. +39 0445 697411 - Fax +39 0445 697414
Email: [email protected]
Asia Pacific
Videotec (HK) Ltd
Flat 8, 19/F. On Dak Industrial Building, No. 2-6 Wah Sing Street
Kwai Chung, New Territories - Hong Kong
Tel. +852 2333 0601 - Fax +852 2311 0026
Email: [email protected]
France
Videotec France SARL
Immeuble Le Montreal, 19bis Avenue du Québec, ZA de Courtaboeuf
91140 Villebon sur Yvette - France
Tel. +33 1 60491816 - Fax +33 1 69284736
Email: [email protected]
Americas
Videotec Security, Inc.
Gateway Industrial Park, 35 Gateway Drive, Suite 100
Plattsburgh, NY 12901 - U.S.A.
Tel. +1 518 825 0020 - Fax +1 518 825 0022
Email: [email protected]
www.videotec.com
MNVCHPVB_2024_EN
Advertisement