MISFEED REMOVAL

When the misfeed ( ) indicator blinks or blinks in the display, the unit will stop because of a misfeed. If a misfeed occurs when using the SPF, a number may appear in the display after a minus sign. This indicates the number of the originals that must be returned to the original feeder tray after a misfeed. Return the required number of originals. Then this number will disappear when copying is resumed or the clear ( ) key is pressed. When the SPF misfeeds an original sheet, the unit will stop and the SPF misfeed ( ) indicator will blink, while the misfeed ( ) indicator will remain off. For a misfeed of originals in the SPF, see "D: Misfeed in the SPF"

(p.64).

If the unit is turned on with the lower side cover open, the misfeed ( ) indicator will blink. In this case, close the lower side cover. The misfeed

( ) indicator will go out.

1

Open the side cover.

To open the side cover, see "INSTALLING THE TD CARTRIDGE" (p.10).

2

Check the misfeed location. Remove the misfed paper following the instructions for each location in the illustration below. If blinks in the display, proceed to "A: Misfeed in the paper feed area" (p.62).

2

3

2

8

61

62

A: Misfeed in the paper feed area

1

Gently remove the misfed paper from the paper feed area as shown in the illustration. When blinks in the display and the misfed paper is not seen from the paper feed area, pull out the paper tray and remove the misfed paper. If the paper cannot be removed, proceed to "B: Misfeed in the fusing area".

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.

• Do not touch the surface of the drum (green portion) of the drum cartridge when removing the misfed paper. Doing so may damage the drum and cause smudges on copies.

• Toner on the paper may stain the paper transport area, resulting in smudges on copies.

2

Close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( ) indicator will light up.

B: Misfeed in the fusing area

1

Lower the fusing unit release lever.

Fusing unit release lever

2

Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the paper cannot be removed, proceed to "C: Misfeed in the transport area".

The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.

• Do not touch the surface of the drum (green portion) of the drum cartridge when removing the misfed paper. Doing so may cause smudges on copies.

• Do not remove the misfed paper from above the fusing unit.

Unfixed toner on the paper may stain the paper transport area, resulting in smudges on copies.

3

Raise the fusing unit release lever and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start

( ) indicator will light up.

C: Misfeed in the transport area

1

Lower the fusing unit release lever.

See "B: Misfeed in the fusing area" (p.62).

2

Open the front cover.

To open the front cover, see "INSTALLING THE TD CARTRIDGE" (p.10).

3

Rotate the feeding roller in the direction of the arrow and gently remove the misfed paper from the exit area.

Feeding roller

8

63

64

4

Raise the fusing unit release lever, close the front cover and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( ) indicator will light up.

Raise the fusing unit release lever, close the front cover and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start ( ) indicator will light up.

D: Misfeed in the SPF

An original misfeed may occur at one of three locations: if the misfed original is seen from the original feeder tray, (A) in the original feeder tray; if the misfed original is not seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller.

Remove the misfed original following the instructions for each location.

(A) Open the feeding roller cover and pull the original gently to the left and out from the original feeder tray. Close the feeding roller cover. Open and close the original cover to clear the SPF misfeed ( ) indicator. If the misfed original cannot be easily removed, proceed to (C).

Feeding roller cover

(B) Open the original cover and rotate the roller rotating knob to remove the misfed original from the exit area. If the misfed original cannot be easily removed, proceed to (C).

Roller rotating knob

(C) If the original does not move easily into the exit area, remove it in the direction of the arrow while rotating the knob.

A number may appear in the display after a minus sign, indicating the number of the originals that must be returned to the original feeder tray.

Open and close the SPF to clear the SFP misfeed

( )

indicator and then clear the misfeed and return the required number of originals. Then press the start ( ) key to resume copying.