2.3 Installation Diagram. Zodiac pH perfect
Add to My manuals20 Pages
Zodiac pH Perfect is a device designed to maintain your pool's pH balance, ensuring optimal water chemistry for your skin, eyes, and hair. It also keeps your sanitizer working efficiently. The pH level is detected by a sensor, and corrective solution is injected into the pool water as needed, keeping it safe and healthy.
advertisement
2.3 Installation Diagram
Installation of the pH Perfect on the filtration system:
It is recommended that pH Perfect be installed after the filter (and any heating device) but before the salt chlorinator cell... if no salt chlorinator is installed it should be the last device on the return line
Hydraulic Diagram
Your pH sensor is a very delicate product and can be affected by external forces such as stray electrical current from other devices.
When connecting the sensor into position try to keep the cable away from other power leads
The maximum pressure in the pipes must not be greater than 1.5 Bar. In order to extend the life of the peristaltic tube, the pressure should not exceed 1 bar
Install the pH Perfect control centre using the supplied fixing kit on a rigid support (a vertical wall) in an easy to access location.
Electrical Diagram
Electrical connection
If you are using an external timer to control your filter pump please plug the ‘piggyback’ plug located on the pH Perfect into the timer and then plug the filter pump into the piggyback plug. This will create a controlled time circuit for pH Perfect with the filter pump.
Now connect the pH Perfect power plug into a power point to power the unit up
4
Warning:
- Acid fumes are highly corrosive
- Do not store acid directly underneath the control unit
- It is preferable to store acid in a safe place outside the filter shed
- If storing inside ensure adequate ventilation is provided
advertisement
Related manuals
advertisement
Table of contents
- 3 1.1 Identification of parts
- 4 1.2 The Control Panel
- 5 2.2 Technical details
- 6 2.3 Installation Diagram
- 7 2.4 Installation of the Sensor POD
- 9 3.1 Calibration procedure
- 10 3.2 Rule for injecting pH Perfect
- 11 3.3 Adjusting the dosage depending on alkalinity
- 12 4.1 “Settings” menu - Default parameters
- 12 4.2 Language
- 12 4.3 Set point
- 13 4.4 Type of dosage
- 13 4.5 Alkalinity level
- 13 4.6 “OFA” over-feed protection
- 14 4.7 Detection that filtration is in progress
- 15 4.8 Resetting the appliance
- 15 5.1 Changing the peristaltic pump tube
- 15 5.2 Winterising the pH Perfect