4.8 Resetting the appliance. Zodiac pH perfect
Add to My manuals20 Pages
Zodiac pH Perfect is a device designed to maintain your pool's pH balance, ensuring optimal water chemistry for your skin, eyes, and hair. It also keeps your sanitizer working efficiently. The pH level is detected by a sensor, and corrective solution is injected into the pool water as needed, keeping it safe and healthy.
advertisement
4.8 Resetting the appliance
In the event of incorrect manipulation, it is possible to restore all the original pH Perfect functional settings.
Procedure for resetting the pH:
Switch OFF the appliance.
Switch ON the appliance by pressing simultaneously on the two “ p ” and “ q ” navigation buttons
(keep the buttons pressed until the message appears on the screen).
Select “Yes” or “No” using the navigation buttons, then accept using the “CAL/Enter” button.
All the factory settings will then be restored.
5. Care and maintenance of your pH Perfect
5.1 Changing the peristaltic pump tube
1. Remove the protective cover carefully drawing it towards you.
2. Position the tablet holder on “10:20” turning clockwise.
4. Position the tablet holder on “10:20” turning clockwise.
Insert the left-hand connection in its housing, then pass the tube under the guide of the tablet holder.
Turn the tablet holder clockwise and at the same time put the tube into the pump head up to the right-hand connection.
3. Fully release the left-hand connection keeping it stretched outwards, then turn the tablet holder clockwise in order to free the tube up to the right-hand connection.
5. Replace the protective cover (place the pin in the attachment hole).
5.2 Winterizing the pH Perfect
When pH Perfect has to be winterised, it is advisable to pump clean water through it in order to rinse the peristaltic pipe using the self-priming function and pressing the navigation button “ p ”
(see paragraph 3.1).
Next turn the tablet holder to “6:00”.
These two precautions will make it easier to restart the appliance.
Remove the pH sensor from its holder. Store it in its original cap or a cup filled with tap water. If necessary plug sensor holder.
Never leave the end of the sensor out of water!
13
6. Water quality
Even though pH Perfect is an automated delivery device it is still a requirement to have the pool water regularly checked for balance and chemistry.
See the table below for recommendations of frequency
Zodiac Group Australia cannot be held liable if these rules are not followed.
pH
Free Chlorine
mg/L or ppm
TA
(alkalinity or buffer effect)°f (ppm)
Recommended
Values
To increase
To reduce
Test Frequency
7.2 – 7.8
Use pH Perfect in “alkaline” dosage and/ or increase setpoint
Use pH perfect in “acid” dosage and/ or decrease setpoint
Weekly
0.5 – 2.0
Add chlorine
(manually or with an ORP regulation)
Stop adding chlorine
Weekly
(80 – 300)
Add sodium bicarbonate
Add diluted hydrochloric acid
Monthly
CH
(level of calcium carbonate
°f (ppm)
(90 - 300)
Add calcium chloride
Cyanuric Acid
(stabiliser) mg/L or ppm
Add cyanuric acid (only if necessary)
Add a scale fixer or carry out decarbonatation
Partially empty the pool and refill it again
Monthly
30 - 50
Quarterly
7. Alarms
Alarm Cause(s) Solutions
The container of corrective solution is empty
First OFA step enabled
(time > 70%)
Second OFA step enabled
(time = 100%)t
Filtration stopped
Replace the container
Check pH value
Press “CAL/Enter” to stop the alarm
Check pH value
Press “CAL/Enter” to stop the alarm
Start filtration pump
Check the connection
Buffer solution ineffective pH sensor defective
Replace the buffer solutions
Clean and/or replace the pH sensor
Parameter error
Press “CAL/Enter” to cancel the fault
Call your local pool professional
14
6. Water quality
7. Alarms
8. Problem solving
Problem Cause Remedy
Displayed pH level doesn't seem to change
Problem with cable and/ or connector
Make sure that the sensor-pH Perfect connection is not short-circuited (between the central core of the cable and the exterior sheathing)
Make sure that there is no moisture and/or condensation around the BNC socket
The electrode connection cable is damaged
Check the cable and/or the BNC socket
The appliance always displays a high value or the measurement is constantly unstable
The pH sensor has an air bubble in the bulb
The pH sensor is worn
The sensor cable is too close to a power cable causing interference
Put the sensor into upright position and shake gently so that the air bubble rises back up to the top
Note:
The sensor should be fitted in a vertical position or at an angle no greater than 45°
Replace the pH sensor
Reduce the distance between the appliance and the sensor and/or place the cable elsewhere
Buffer solution is ineffective
Make sure that the solution hasn't expired
Check the pH buffer solution with a pH electronic meter
Impossible to calibrate
(error message)
Quality of calibration of the pH sensor
< 25%
Problem with the sensor’s porous element, dirt deposits
Make sure that the electrode bulb is in good condition, that it has not been allowed to dry out of the water. As a last resort, clean by soaking the electrode in a 10% hydrochloric acid solution
Check that the porosity of the sensor is in good condition (wash the sensor in an acid solution).
The pH sensor is worn
Check the pH buffer solution with a pH electronic meter
Slow response from the pH sensor
Static electricity on the pH sensor
Replace the pH sensor
During the calibration phase DO NOT WIPE the pH sensor with a cloth or paper, but after rinsing, shake it gently
15
9. Warranty
Express Warranty and Guarantees
Zodiac Group Australia Pty Ltd (Zodiac Australia) warrants that the Zodiac pH Perfect (Product) will be free from defects in materials and workmanship for a period of 2 years from date of purchase.
Terms & Conditions
1. This express warranty only applies if the Product has been purchased from a dealer authorised by
Zodiac Australia to supply it (Authorised Dealer). Purchase from an Authorised Dealer ensures that the product is a genuine Zodiac product, that it is the version designed for Asia Pacific conditions, and that the Purchaser has access to appropriate technical knowledge and advice.
2. Zodiac Australia's liability under this express warranty is limited, at its option, to the repair or replacement of the Product or the payment of the cost of having the Product repaired or replaced.
3. This express warranty does not apply in the following circumstances:
(a) if the Product has not been installed in accordance with Zodiac's installation instructions;
(b) if the Product has been modified other than as authorised by Zodiac Australia or if a component part has been replaced by a part that is not a genuine Zodiac product;
(c) if a defect results from use of the Product outside recommended operating conditions; or
(d) if a defect results from damage (including damage to any internal electronics) caused by a power surge or lightning strike.
4. Without limiting 3 above, products sold by Zodiac Australia are designed for use with swimming pool water balanced in accordance with Australian Standard AS3633–1989 with a pH range of 7.0 – 7.8.
Maximum chlorine readings should not exceed 4ppm. Where pool water is not maintained within these parameters, Zodiac Australia will not be responsible under this express warranty for any resulting damage, including damage caused by corrosion, scaling or stress loading.
5. Replacement parts supplied under this express warranty are warranted to be free from defects in materials and workmanship for the remainder of the warranty period or for 12 months from the supply of the replacement, whichever is longer.
Product warranty registration
6. Purchasers should register their Products as soon as conveniently possible after purchase by completing a Product Warranty Registration Form and posting it to Zodiac Australia at the address shown on the Form or by registering online at www.zodiac.com.au.
7. Product registration must occur, and proof of purchase must be received by Zodiac Australia, prior to any warranty work being approved. Where applicable, a serial number, installation date and name of installer is required as part of the registration process.
How to make a warranty claim
8. The Purchaser must telephone or email Zodiac Australia Customer Service and obtain a warranty ID number for the warranty claim. Contact details are:
Zodiac Group Australia Pty Ltd Customer Service
219 Woodpark Road
Smithfield NSW 2164
Telephone: 1800 688 552
Email address: [email protected]
16
9. Warranty
9. Zodiac Australia reserves the right to determine, in relation to each warranty claim, whether the
Product should be returned to the Authorised Dealer at the address where the Purchaser purchased the Product or whether warranty service will be provided in the field, repaired at a Zodiac workshop or at the premises of an authorized Zodiac warranty agent.
10. If it is necessary for the Purchaser to incur freight charges in making a valid claim under this warranty, Zodiac Australia will reimburse the Purchaser for charges reasonably incurred upon proof of the charges.
Additional guarantees, rights and remedies
Australian Purchasers – Guarantees under the Australian Consumer Law
11. The benefits of this express warranty are in addition to other guarantees, rights and remedies
Australian consumers have under the Australian Consumer Law.
12. Zodiac Australia products come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Purchasers in other Countries
13. The laws and regulations of other countries may confer on Purchasers in those countries additional rights and remedies. To the extent that they cannot be excluded or modified, Purchasers have the benefits of those rights and remedies in addition to the benefits of this express warranty. To the full extent that it is permissible to do so, those additional rights and remedies are excluded or modified so as to be consistent with Zodiac Australia's express warranty.
INCONSISTENCY WITH WARRANTY STATEMENTS IN PRODUCT MANUALS
OR OTHER DOCUMENTS ACCOMPANYING PRODUCTS
If any warranty statements in a Zodiac Australia product manual or other document are inconsistent with the above Express Warranty and Guarantees, the above overrides and replaces the inconsistent statements.
10. Online registration
Registration on line
Register your product on our website:
• you will be the first to be informed of new Zodiac products and special offers,
• You can help us to constantly improve the quality of our products.
Australia – New Zealand
www.zodiac.com.au
17
Zodiac is a registered trademark of Zodiac Group Australia Pty Ltd
ABN 87 002 641 965
ZODIAC CUSTOMER SERVICE CENTRE
Zodiac Group Australia:
219 Woodpark Rd, Smithfield,
NSW 2164 Australia
Tel: 1300 763 021
Fax: 1300 781 688
Email: [email protected]
www.zodiac.com.au
Due to constant developments and improvements, specifications may change without notice.
Improper use could affect performance and void warranty.
© Copyright Zodiac Australian Ltd 2016
Your Retailer
advertisement
Related manuals
advertisement
Table of contents
- 3 1.1 Identification of parts
- 4 1.2 The Control Panel
- 5 2.2 Technical details
- 6 2.3 Installation Diagram
- 7 2.4 Installation of the Sensor POD
- 9 3.1 Calibration procedure
- 10 3.2 Rule for injecting pH Perfect
- 11 3.3 Adjusting the dosage depending on alkalinity
- 12 4.1 “Settings” menu - Default parameters
- 12 4.2 Language
- 12 4.3 Set point
- 13 4.4 Type of dosage
- 13 4.5 Alkalinity level
- 13 4.6 “OFA” over-feed protection
- 14 4.7 Detection that filtration is in progress
- 15 4.8 Resetting the appliance
- 15 5.1 Changing the peristaltic pump tube
- 15 5.2 Winterising the pH Perfect