advertisement
680 SERIES
L3*
Lock Mode (disables the temperature up and down buttons to prevent unauthorized temperature adjustments). Filtration/heating cycle will continue to operate as programmed in this mode. The jets and lights buttons will still continue to operate as normal. The temperature display flashes when this function is enabled. *Due to a difference in software this feature is not available for all models.
Note:
To exit a Lock Mode you will need to re-enter the filtration/heating modes and select a cycle from F1-F6.
10.6 Programming the CLEARRAY (Ultraviolet) Water Purification
System
A.
Programming the
CLEAR
RAY System (U) or Corona Discharge
Ozone (O3)
Press and hold the
Jets pump 1
( ) and
Cooler
( ) button
at the same time
for 3 seconds to enter the sanitizing system program. The screen will display one of the two menus below:
CLEAR
RAY
menu
Press
O3 menu
Press or or
1. If the LED screen is displaying “U” then pressing the Jets pump
1 will change the sanitizing system from “U” to “O3” and exit the programming menu. If the LED screen is displaying “O3” then pressing the Jets pump 1 will change the sanitizing system from “O3” to “U” and exit the programming menu.
Note:
For the O3 option the “=” disables the duration countdown timer.
2. If you do not wish to change the option do not press any buttons and after 10 seconds the display will return to the main menu.
Note:
If the CLEAR
RAY
System has been selected, when the time allotted has expired (365 days) the display screen will flash between the water temperature and “blb.” At this time the UV bulb must be replaced, the quartz tube must be cleaned and the duration countdown timer needs to be reset.
Page 32
680 SERIES
B.
Resetting the duration countdown timer (
CLEAR
RAY System only)
Once the duration countdown timer for the CLEAR
RAY
System has reached zero, you will need to reset it, replace the UV bulb and clean the quartz tube.
To reset the duration countdown timer:
Press Press
1
1. Press and hold the
Jets pump 1
( ) and
Cooler
( ) button
at the same time
for 3 seconds.
2. Press the
Warmer
( ) button until the display shows “0.”
3. If the timer has reached “0,” pressing the
Jets pump 1
( ) button will reset it.
If the timer is not at “0” pressing the Jets pump 1 button will not reset it.
Note:
If the spa power is interrupted, the duration countdown timer is not affected. The number of days remaining is stored in the memory and will continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it: a. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
b. Press the Warmer button to scroll to “U.” c. Press the Jets pump 1 button to switch from “U” to “O3.” d. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
e. Press the Warmer button to scroll to “O3.” f. Press the Jets pump 1 button to switch from “O3” to “U.” The timer has been reset to 365 days.
Page 33
advertisement
Related manuals
advertisement
Table of contents
- 7 Important Spa Owner Information
- 7 FCC Notice
- 8 Important Safety Instructions for all Spa Owners
- 12 Entrapment Risk
- 13 Hyperthermia
- 14 Important CSA Safety Instructions (Canada only)
- 14 General Electrical Safety Instructions
- 15 Choosing A Location
- 16 Outdoor Location
- 17 Indoor Location
- 18 Power Requirements
- 18 North American 60 Hz Power Options
- 19 Export 50 Hz Power Options
- 20 Electrical Wiring Instructions
- 24 Spa Fill Up Procedure
- 29 Control Functions
- 29 Control Panel
- 30 General Spa Features And Controls
- 31 and Peyton Models)
- 32 Operating Instructions
- 32 Setting Water Temperature
- 33 Activate Pumps
- 33 SunGlow™ Light Operation (Denali and Tacoma Models)
- 34 (Edison®, Hartford, Hawthorne, and Peyton Models)
- 35 Adjusting Individual Jet Flow
- 35 Selecting Desired Massage Action
- 35 Air Controls
- 35 Optional BLUEWAVE™ Spa Stereo System
- 36 10.0 Automatic Filtration Cycles
- 36 Standard Filtration/Heating Modes (F1-F3)
- 36 Economy Filtration/Heating Modes (F4-F6)
- 36 Lock Modes (L1-L3)
- 36 Selecting The Filtration/Heating Mode
- 37 Filtration Modes
- 38 Water Purification System
- 40 11.0 Spa Maintenance
- 40 Cleaning The Filter
- 41 Draining and Refilling
- 42 Pillow Care (All Models Except Denali)
- 43 Cleaning The Spa Interior
- 43 Maintaining The Cover
- 44 Maintaining The Synthetic Cabinet
- 44 11.7 Winterizing
- 45 Restarting Your Spa in Cold Weather
- 45 12.0 Water Quality Maintenance
- 46 pH Control
- 46 Sanitizing
- 47 ® Water Purification System
- 47 Quartz Tube Maintenance
- 50 13.0 Error Conditions/Error Messages
- 50 Panel Displays SN
- 50 Panel Flashes FL1 or FL
- 51 Panel Displays COL
- 51 Panel Displays ICE
- 51 Panel Displays OH
- 51 Panel Displays
- 51 Panel Displays BLB
- 52 14.0 Troubleshooting Procedures
- 52 None of the Components Operate (e.g. Pump, Light)
- 52 Pump Does Not Operate but Light Does
- 52 Poor Jet Action
- 52 Water is Too Hot
- 52 No Heat
- 54 Circuit Diagram (60 Hz)
- 55 and Peyton Circuit Diagram (60 Hz)
- 56 17.0 Export Denali/Tacoma Circuit Diagram (50 Hz)
- 57 Peyton Circuit Diagram (50 Hz)
- 58 19.0 Optional BLUEWAVE™ Spa Stereo System
- 59 Pairing the Remote and Stereo
- 59 Audio Settings
- 61 Wireless Remote Control Functions
- 62 Electronic Device Connections and Functions
- 65 Wireless Remote Battery Replacement Procedure
- 66 BLUEWAVE Spa Stereo System Specifications
- 66 Stereo Cautions