680 SERIES
During spa use or an automatic filter cycle, water flows through the spa skimmer and into both polyester mesh filter cartridges to trap suspended particles and oils on their surface pleats. To ensure optimum performance, it is necessary to remove and clean both filter cartridges once a month or sooner depending on spa use and water quality.
B.
Denali, Edison, Peyton and Tacoma Models:
Your Sundance spa is equipped with a skimmer basket and filter cartridge located in the skimmer/filter well. Filtering is accomplished when the pump turns on in low speed to initiate water flow through the skimmer basket and polyester mesh filter cartridge. As this happens, suspended particles become trapped on the filter’s surface. To ensure optimum performance, it is necessary to remove and clean the skimmer basket once a week and filter cartridge once a month or sooner, depending on usage and water quality.
SPA SHELL
C.
Cleaning Procedure (for All Models):
1.
Turn off power to the spa at the home’s breaker panel or select the L1 “Lock” mode (page 30) to disable all spa functions.
2. Remove the filter strainer lid or skimmer assembly.
3. Remove the filter cartridge by rotating it counterclockwise to unthread it from the filter wall fitting, then lift it straight up to remove from filter well.
4. Using a garden hose with a high-pressure nozzle to rinse debris from the filter pleats beginning at the top and working your way downward.
Continue, one section at a time, until you have rinsed all of the filter’s pleats.
Periodically, the filter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as above and then soaking the cartridge overnight in a plastic container filled with a solution of water and a specially formulated filter cleanser available from your authorized Sundance dealer. The average life expectancy of a Sundance filter cartridge is approximately two years with proper care and water quality maintenance. A replacement cartridge may be purchased from your dealer.
11.2 Draining and Refilling
About every 3 months, you will want to replace the spa’s water. The frequency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water even though the key water balance measurements are all within the proper parameters.
Page 35
advertisement
Related manuals
advertisement
Table of contents
- 7 Important Spa Owner Information
- 7 FCC Notice
- 8 Important Safety Instructions for all Spa Owners
- 12 Entrapment Risk
- 13 Hyperthermia
- 14 Important CSA Safety Instructions (Canada only)
- 14 General Electrical Safety Instructions
- 15 Choosing A Location
- 16 Outdoor Location
- 17 Indoor Location
- 18 Power Requirements
- 18 North American 60 Hz Power Options
- 19 Export 50 Hz Power Options
- 20 Electrical Wiring Instructions
- 24 Spa Fill Up Procedure
- 29 Control Functions
- 29 Control Panel
- 30 General Spa Features And Controls
- 31 and Peyton Models)
- 32 Operating Instructions
- 32 Setting Water Temperature
- 33 Activate Pumps
- 33 SunGlow™ Light Operation (Denali and Tacoma Models)
- 34 (Edison®, Hartford, Hawthorne, and Peyton Models)
- 35 Adjusting Individual Jet Flow
- 35 Selecting Desired Massage Action
- 35 Air Controls
- 35 Optional BLUEWAVE™ Spa Stereo System
- 36 10.0 Automatic Filtration Cycles
- 36 Standard Filtration/Heating Modes (F1-F3)
- 36 Economy Filtration/Heating Modes (F4-F6)
- 36 Lock Modes (L1-L3)
- 36 Selecting The Filtration/Heating Mode
- 37 Filtration Modes
- 38 Water Purification System
- 40 11.0 Spa Maintenance
- 40 Cleaning The Filter
- 41 Draining and Refilling
- 42 Pillow Care (All Models Except Denali)
- 43 Cleaning The Spa Interior
- 43 Maintaining The Cover
- 44 Maintaining The Synthetic Cabinet
- 44 11.7 Winterizing
- 45 Restarting Your Spa in Cold Weather
- 45 12.0 Water Quality Maintenance
- 46 pH Control
- 46 Sanitizing
- 47 ® Water Purification System
- 47 Quartz Tube Maintenance
- 50 13.0 Error Conditions/Error Messages
- 50 Panel Displays SN
- 50 Panel Flashes FL1 or FL
- 51 Panel Displays COL
- 51 Panel Displays ICE
- 51 Panel Displays OH
- 51 Panel Displays
- 51 Panel Displays BLB
- 52 14.0 Troubleshooting Procedures
- 52 None of the Components Operate (e.g. Pump, Light)
- 52 Pump Does Not Operate but Light Does
- 52 Poor Jet Action
- 52 Water is Too Hot
- 52 No Heat
- 54 Circuit Diagram (60 Hz)
- 55 and Peyton Circuit Diagram (60 Hz)
- 56 17.0 Export Denali/Tacoma Circuit Diagram (50 Hz)
- 57 Peyton Circuit Diagram (50 Hz)
- 58 19.0 Optional BLUEWAVE™ Spa Stereo System
- 59 Pairing the Remote and Stereo
- 59 Audio Settings
- 61 Wireless Remote Control Functions
- 62 Electronic Device Connections and Functions
- 65 Wireless Remote Battery Replacement Procedure
- 66 BLUEWAVE Spa Stereo System Specifications
- 66 Stereo Cautions