Basic Operation. Labor Saving Devices AT-OMNI-324

Add to My manuals
32 Pages

advertisement

Basic Operation. Labor Saving Devices AT-OMNI-324 | Manualzz

Basic Operation

LED Indicators

The

PWR

,

LINK

,

HOST

, and

SIGNAL

LED indicators on the OmniStream 324 provide basic information on the current status of the unit.

LED

PWR

LINK

HOST

SIGNAL

Solid green

Off

Solid green

Blinking green

(slow)

Blinking green

(fast)

Off

Solid green

Blinking green

Blinking green

Off

Description

Unit is powered.

Unit is not powered.

• Verify that the included power supply is connected to the AT-

OMNI-324 and the power supply are connected to a live electrical outlet.

The link integrity between the receiver and the transmitter is good.

The receiver is attempting to establish a link to the transmitter.

The receiver is in Pairing Mode.

There is no link between the receiver and the transmitter.

• Direct Mode:

Verify that an Ethernet cable is connected between the

LAN

port on the receiver and the transmitter.

• Network Mode:

Verify that an Ethernet cable is connected between the

LAN

port on the receiver and the network switch.

• Check that the Ethernet cable is not physically damaged.

• Make sure that the Ethernet cable does not exceed 330 feet (100 meters).

The transmitter is properly enumerated on the host computer.

The transmitter is in a suspended state.

This LED indicator will blink intermittently when data is being transmitted between the receiver and the transmitter.

The receiver is in Suspend Mode.

AT-OMNI-324 12

Basic Operation

Pairing

Pairing an OmniStream 324 to an OmniStream 311 (not incuded) is managed using the Atlona Management System

(AMS). AMS is free and can be downloaded from https://atlona.com/AMS. The pairing process can also be performed using the Server Appliance for Atalona Management System (AT-AMS-HW).

Using AMS

1. Launch a web browser and enter the IP address of AMS, in the address bar.

2. Enter the required login credentials.

3. Click the

Login

button.

4. The AMS Dashboard will be displayed.

5. Click the icon, in the upper-left corner of the AMS Dashboard.

6. Click

Devices

>

Unassigned

from the fly-out menu.

All available OmniStream 324 devices will be displayed under the

Unassigned

category. When a device is unassigned, it means that the device has not yet been assigned to a site, building, and/or room. Refer to the

AMS User Manual for more information on these topics.

AT-OMNI-324 13

7. Click the AT-OMNI-324 from the

Unassigned

list.

Basic Operation

8. The

DEVICE INFO

page for the AT-OMNI-324 will be displayed. Click the

PAIRING

tab.

AT-OMNI-324 14

Basic Operation

9. Click the Pairing drop-down list and select the desired OmniStream 311. In this example, only a single

OmniStream 311 is connected to the network. Therefore, this is the only available option. Up to seven

OmniStream 324 units can be paired to an OmniStream 311.

10. Click the

SAVE

button at the bottom of the page.

11. The pairing process is complete. Repeat steps 7 through 10 for each OmniStream 324 on the network.

To unpair an OmniStream 324 from an OmniStream 311, select

None

from the drop-down list and then click the

SAVE

button.

AT-OMNI-324 15

Basic Operation

Manual Pairing

The OmniStream 311 and OmniStream 324 can also be paired manually. This applies when the OmniStream 311 and OmniStream 324 are connected, either through a network switch (on the same broadcast domain) or directly to one another using category cable. This instructions below cover manual pairing for both the OmniStream 311 and

OmniStream 324.

1. Make sure both the OmniStream 311 and OmniStream 324 are connected, either directly or through a network switch, and that all USB connections have been made.

OmniStream 311

2. Press and hold the

PAIRING

button, for no more than 10 seconds, on the OmniStream 311 using the end of a paperclip or other pointed object.

IMPORTANT:

Pressing the

PAIRING

button for

more

than 10 seconds will cancel the pairing mode.

PAIRING button

AT-OMNI-311 AT-OMNI-324

UTILITY PAIRING HOST LAN DC 24V UTILITY PAIRING LAN

3. Release the

PAIRING

button. The

LINK

LED indicator will begin flashing. Pairing mode is now active on the

OmniStream 311.

PWR HOST

PWR

NOTE:

To cancel pairing mode, press and hold the

PAIRING

button for more than 10 seconds.

O

MNI

S

TREAM

TM

O

MNI

S

TREAM TM

HOST

SIGNAL

OmniStream 324

4. Press and hold the

PAIRING

button on the OmniStream 324, for

no more

than 10 seconds, using the end of a paperclip or other pointed object.

IMPORTANT:

Pressing the

PAIRING

button for

more

than 10 seconds will cancel the pairing mode.

The

PAIRING

button on the OmniStream 324 must be pressed within 10 minutes of activating pairing mode on the OmniStream 311. If not, then the pairing process will automatically be cancelled.

5. Release the

PAIRING

button. The

LINK

LED indicator will begin flashing. Pairing mode is now active on the

OmniStream 324.

The OmniStream 311 and OmniStream 324 will begin the linking process. During the linking process, the

LINK

LED indicator on both unit may flash more slowly. This is normal behavior.

Once both

LINK

LED indicators are solid green, the pairing process will be complete.

Unpairing an Extender

To unpair one extender from the other, press and hold the

PAIRING

button, on either of the connected units, for

more

than 10 seconds, then release.

AT-OMNI-324 16

Basic Operation

Using Velocity™

The following section provides instructions on pairing AT-OMNI-311 units with AT-OMNI-324 units using the Atlona

Velocity Control Software. Familiarity with the Velocity software is assumed. Refer to the

Atlona Velocity User

Manual

for more information, if necessary.

1. Launch a web browser and enter the IP address of Velocity, in the address bar.

2. Enter the required login credentials.

3. Click the

Login

button.

4. The Velocity Dashboard will be displayed.

5. Click the icon, in the upper-left corner, to display the fly-out menu.

Click to display fly-out menu

6. Click

Sites

in the menu bar to expand the list of buildings and rooms.

7. Click the desired room from the list.

In the example on the right, a set of units have been set up in a room called

Omni 311 324

within

Building 1

.

Refer to the

Velocity User Manual

for instructions on creating rooms and adding devices to rooms.

AT-OMNI-324 17

Basic Operation

8. The

Modify Room

screen will be displayed. Click the

Room Control Options

icon, in the upper-right corner of the

Technology

bar.

Room Control Options icon

9. The

Room Control Options

screen will be displayed. In order to allow units to be paired or unpaired, two macros will need be created: one for pairing and one for unpairing.

10. Click the

Macros

icon to display the

Room Macros

screen.

AT-OMNI-324 18

Creating the Unpair Macro

1. In the

Room Macros

screen, click the

+

icon, in the upper-right corner of the screen.

Basic Operation

2. Enter the name of the macro in both the

Name

and

Macro Commands

text field. The name of the macro should be descriptive of what option is being performed.

3. Click the

+

icon to display the macro configuration dialog.

Macro Configuration icon

4. Click the

Device

drop-down list and select one of the device from this list. Since the “Unpair” macro will disconnect the two units from one another, either the AT-OMNI-311 or AT-OMNI-324 can be selected from this drop-down list. In this example, the AT-OMNI-324 is selected.

5. Click the

Command

drop-down list and select

Remove All Pairings

.

6. Repeat steps 3 through 5: when repeating theses steps, select the AT-OMNI-311 from the

Device

drop-down list.

7. Click the

Save

icon in the top-right portion of the

Room Macros

bar.

AT-OMNI-324 19

Creating the Pair Macro

1. In the

Room Macros

screen, click the

+

icon, in the upper-right corner of the screen.

Basic Operation

2. Enter the name of the macro in both the

Name

and

Macro Commands

text field. In this example, “Pair” will be used.

3. Click the

+

icon to display the macro configuration dialog.

4. Click the

Device

drop-down list and select the AT-OMNI-324.

5. Click the

Command

drop-down list and select

Pair (Auto)

.

6. Click the second

Device

drop-down list and select the unit to be paired. Since the AT-OMNI-324 was already selected, select the AT-OMNI-311 from the drop-down list.

7. Repeat steps 2 through 5: For the first

Device

drop-down list, select the AT-OMNI-324, and for the second

Device

drop-down list, select the AT-OMNI-311. When this macro is completed, it should appear similar to the following:

8. Click the

Save

icon, in the top-right portion of the

Room Macros

bar.

AT-OMNI-324 20

Basic Operation

Pairing and Unpairing Units

IMPORTANT:

Before pairing units, make sure to unpair (remove) any existing pairings using the

“unpair” macro that was created on page 19.

1. Click the

icon for the “Unpair” macro. This will remove any possible “out-of-the-box” (factory) pairing that may exist.

2. Click the

► icon for the “Pair” macro to pair the two units.

Example: Pairing two AT-OMNI-324 to a single AT-OMNI-311

The following illustration depicts an example of how to pair two AT-OMNI-324 units to a single AT-OMNI-311.

Refer to the instructions on the following page for how to configure this setup. Note that arbitrary IP addresses have been assigned for reference.

Laptop

USB

AT-OMNI-311

O

MNI

S TREAM

TM

192.168.11.127

PWR

LINK

HOST

SIGNAL

Ethernet

LAN

AT-OMNI-324

AT-OMNI-324

Ethernet

AT-OMNI-324

PWR

LINK

HOST

SIGNAL

O

S TREAM

TM

192.168.11.124

PWR

LINK

HOST

SIGNAL

O MNI

S

TM

192.168.11.123

Microphone

Web Cam

21

Basic Operation

1. In the

Room Macros

screen, click the icon, in the upper-right corner of the screen.

2. Enter “Unpair” for both the

Name

and

Macro Commands

text field.

3. Click the

+

icon to display the macro configuration dialog.

4. Click the

Device

drop-down list and select one of the devices from this list. Since the “Unpair” macro will be disconnecting a total of three units from one another, the “Unpair” macro will contain a total of three commands.

In this example, the AT-OMNI-324 is arbitrarily selected.

5. Click the

Command

drop-down list and select

Remove All Pairings

.

6. Repeat steps 3 through 5, selecting the second AT-OMNI-324 and then the AT-OMNI-311 from the

Device

dropdown list. When completed, the “Unpair” macro should appear as follows:

AT-OMNI-324 22

Basic Operation

9. Click the

Save

icon in the top-right portion of the

Room Macros

bar.

10. Create a “pairing” macro by clicking the icon, in the upper-right corner of the screen.

Note that since there are two AT-OMNI-324 units, creating the “Pair” macro can be achieved using two different methods: a. Create two separate macros: one to pair the AT-OMNI-311 and the AT-OMNI-324 with the camera, and another one to pair the AT-OMNI-311 with the AT-OMNI-324 with the speakerphone. This method provides more control, providing the option of which AT-OMNI-324 is paired with the AT-OMNI-311.

b. Create a single macro which pairs both AT-OMNI-324 units to the AT-OMNI-311. This method is more convenient, but does not provide the option of which AT-OMNI-324 is paired with the AT-OMNI-311.

For this example, two separate pairing macros will be created:

9. Enter “Pair to camera” in both the

Name

and

Macro Commands

text field. This macro will be used to pair the computer with the camera.

10. Click the

+

icon to display the macro configuration dialog.

11. Click the

Device

drop-down list and select the AT-OMNI-324 that is connected to the camera. In this example, the AT-OMNI-324 with the IP address of 192.168.11.124 will be selected.

12. Click the

Command

drop-down list and select

Pair (Auto)

.

13. Click the second

Device

drop-down list and select the AT-OMNI-311.

14. Repeat steps 10 through 13: select the AT-OMNI-311 in the first

Device

drop-down list, and then the AT-

OMNI-324 with the camera, from the second

Device

drop-down list. The “Pair to camera” macro should now appear as follows:

AT-OMNI-324 23

Basic Operation

9. Click the

Save

icon in the top-right portion of the

Room Macros

bar.

10. Click the icon, in the upper-right corner of the screen to create the final macro. This macro will be used to pair the computer with the speakerphone.

11. Enter “Pair to speaker” in both the

Name

and

Macro Commands

text field.

12. Click the

+

icon to display the macro configuration dialog.

13. Click the

Device

drop-down list and select the AT-OMNI-324 that is connected to the speakerphone. The AT-

OMNI-324 with the IP address of 192.168.11.123 will be selected

14. Click the

Command

drop-down list and select

Pair (Auto)

.

15. Click the second

Device

drop-down list and select the AT-OMNI-311.

16. Repeat steps 18 through 21: select the AT-OMNI-311 in the first

Device

drop-down list, and then the AT-

OMNI-324 with the speakerphone, from the second

Device

drop-down list. The “Pair to speaker” macro should now appear as follows:

17. Click the

Save

icon in the top-right portion of the

Room Macros

bar.

AT-OMNI-324 24

Basic Operation

DHCP Reset

Use the following instructions to reset the device to DHCP mode. Resetting to DHCP mode will not remove any pairings and if the device is already paired, it will remain paired.

1. Disconnect power from the unit.

2. Reconnect power to the unit, and within 5 seconds, press and hold the

PAIRING

button.

PAIRING button

AT-OMNI-324

DC 24V

UTILITY PAIRING

LAN

3. Continue holding the

PAIRING

button for 15 seconds, then release.

4. Power-cycle the unit once again, by disconnecting and reconnecting the power. Let the unit boot up normally.

O

MNI

S

TREAM

TM

LINK SIGNAL

5. The unit is now in DHCP mode and will automatically be assigned an IP address by the DHCP server, if one is present on the network.

AT-OMNI-324 25

advertisement

Related manuals