Basic Operation
LED Indicators
The
PWR
,
LINK
,
HOST
, and
SIGNAL
LED indicators on the OmniStream 324 provide basic information on the current status of the unit.
LED
PWR
LINK
HOST
SIGNAL
Solid green
Off
Solid green
Blinking green
(slow)
Blinking green
(fast)
Off
Solid green
Blinking green
Blinking green
Off
Description
Unit is powered.
Unit is not powered.
• Verify that the included power supply is connected to the AT-
OMNI-324 and the power supply are connected to a live electrical outlet.
The link integrity between the receiver and the transmitter is good.
The receiver is attempting to establish a link to the transmitter.
The receiver is in Pairing Mode.
There is no link between the receiver and the transmitter.
• Direct Mode:
Verify that an Ethernet cable is connected between the
LAN
port on the receiver and the transmitter.
• Network Mode:
Verify that an Ethernet cable is connected between the
LAN
port on the receiver and the network switch.
• Check that the Ethernet cable is not physically damaged.
• Make sure that the Ethernet cable does not exceed 330 feet (100 meters).
The transmitter is properly enumerated on the host computer.
The transmitter is in a suspended state.
This LED indicator will blink intermittently when data is being transmitted between the receiver and the transmitter.
The receiver is in Suspend Mode.
AT-OMNI-324 12
Basic Operation
Pairing
Pairing an OmniStream 324 to an OmniStream 311 (not incuded) is managed using the Atlona Management System
(AMS). AMS is free and can be downloaded from https://atlona.com/AMS. The pairing process can also be performed using the Server Appliance for Atalona Management System (AT-AMS-HW).
Using AMS
1. Launch a web browser and enter the IP address of AMS, in the address bar.
2. Enter the required login credentials.
3. Click the
Login
button.
4. The AMS Dashboard will be displayed.
5. Click the icon, in the upper-left corner of the AMS Dashboard.
6. Click
Devices
>
Unassigned
from the fly-out menu.
All available OmniStream 324 devices will be displayed under the
Unassigned
category. When a device is unassigned, it means that the device has not yet been assigned to a site, building, and/or room. Refer to the
AMS User Manual for more information on these topics.
AT-OMNI-324 13
7. Click the AT-OMNI-324 from the
Unassigned
list.
Basic Operation
8. The
DEVICE INFO
page for the AT-OMNI-324 will be displayed. Click the
PAIRING
tab.
AT-OMNI-324 14
Basic Operation
9. Click the Pairing drop-down list and select the desired OmniStream 311. In this example, only a single
OmniStream 311 is connected to the network. Therefore, this is the only available option. Up to seven
OmniStream 324 units can be paired to an OmniStream 311.
10. Click the
SAVE
button at the bottom of the page.
11. The pairing process is complete. Repeat steps 7 through 10 for each OmniStream 324 on the network.
To unpair an OmniStream 324 from an OmniStream 311, select
None
from the drop-down list and then click the
SAVE
button.
AT-OMNI-324 15
Basic Operation
Manual Pairing
The OmniStream 311 and OmniStream 324 can also be paired manually. This applies when the OmniStream 311 and OmniStream 324 are connected, either through a network switch (on the same broadcast domain) or directly to one another using category cable. This instructions below cover manual pairing for both the OmniStream 311 and
OmniStream 324.
1. Make sure both the OmniStream 311 and OmniStream 324 are connected, either directly or through a network switch, and that all USB connections have been made.
OmniStream 311
2. Press and hold the
PAIRING
button, for no more than 10 seconds, on the OmniStream 311 using the end of a paperclip or other pointed object.
IMPORTANT:
Pressing the
PAIRING
button for
more
than 10 seconds will cancel the pairing mode.
PAIRING button
AT-OMNI-311 AT-OMNI-324
UTILITY PAIRING HOST LAN DC 24V UTILITY PAIRING LAN
3. Release the
PAIRING
button. The
LINK
LED indicator will begin flashing. Pairing mode is now active on the
OmniStream 311.
PWR HOST
PWR
NOTE:
To cancel pairing mode, press and hold the
PAIRING
button for more than 10 seconds.
O
MNI
S
TREAM
TM
O
MNI
S
TREAM TM
HOST
SIGNAL
OmniStream 324
4. Press and hold the
PAIRING
button on the OmniStream 324, for
no more
than 10 seconds, using the end of a paperclip or other pointed object.
IMPORTANT:
Pressing the
PAIRING
button for
more
than 10 seconds will cancel the pairing mode.
The
PAIRING
button on the OmniStream 324 must be pressed within 10 minutes of activating pairing mode on the OmniStream 311. If not, then the pairing process will automatically be cancelled.
5. Release the
PAIRING
button. The
LINK
LED indicator will begin flashing. Pairing mode is now active on the
OmniStream 324.
The OmniStream 311 and OmniStream 324 will begin the linking process. During the linking process, the
LINK
LED indicator on both unit may flash more slowly. This is normal behavior.
Once both
LINK
LED indicators are solid green, the pairing process will be complete.
Unpairing an Extender
To unpair one extender from the other, press and hold the
PAIRING
button, on either of the connected units, for
more
than 10 seconds, then release.
AT-OMNI-324 16
Basic Operation
Using Velocity™
The following section provides instructions on pairing AT-OMNI-311 units with AT-OMNI-324 units using the Atlona
Velocity Control Software. Familiarity with the Velocity software is assumed. Refer to the
Atlona Velocity User
Manual
for more information, if necessary.
1. Launch a web browser and enter the IP address of Velocity, in the address bar.
2. Enter the required login credentials.
3. Click the
Login
button.
4. The Velocity Dashboard will be displayed.
5. Click the icon, in the upper-left corner, to display the fly-out menu.
Click to display fly-out menu
6. Click
Sites
in the menu bar to expand the list of buildings and rooms.
7. Click the desired room from the list.
In the example on the right, a set of units have been set up in a room called
Omni 311 324
within
Building 1
.
Refer to the
Velocity User Manual
for instructions on creating rooms and adding devices to rooms.
AT-OMNI-324 17
Basic Operation
8. The
Modify Room
screen will be displayed. Click the
Room Control Options
icon, in the upper-right corner of the
Technology
bar.
Room Control Options icon
9. The
Room Control Options
screen will be displayed. In order to allow units to be paired or unpaired, two macros will need be created: one for pairing and one for unpairing.
10. Click the
Macros
icon to display the
Room Macros
screen.
AT-OMNI-324 18
Creating the Unpair Macro
1. In the
Room Macros
screen, click the
+
icon, in the upper-right corner of the screen.
Basic Operation
2. Enter the name of the macro in both the
Name
and
Macro Commands
text field. The name of the macro should be descriptive of what option is being performed.
3. Click the
+
icon to display the macro configuration dialog.
Macro Configuration icon
4. Click the
Device
drop-down list and select one of the device from this list. Since the “Unpair” macro will disconnect the two units from one another, either the AT-OMNI-311 or AT-OMNI-324 can be selected from this drop-down list. In this example, the AT-OMNI-324 is selected.
5. Click the
Command
drop-down list and select
Remove All Pairings
.
6. Repeat steps 3 through 5: when repeating theses steps, select the AT-OMNI-311 from the
Device
drop-down list.
7. Click the
Save
icon in the top-right portion of the
Room Macros
bar.
AT-OMNI-324 19
Creating the Pair Macro
1. In the
Room Macros
screen, click the
+
icon, in the upper-right corner of the screen.
Basic Operation
2. Enter the name of the macro in both the
Name
and
Macro Commands
text field. In this example, “Pair” will be used.
3. Click the
+
icon to display the macro configuration dialog.
4. Click the
Device
drop-down list and select the AT-OMNI-324.
5. Click the
Command
drop-down list and select
Pair (Auto)
.
6. Click the second
Device
drop-down list and select the unit to be paired. Since the AT-OMNI-324 was already selected, select the AT-OMNI-311 from the drop-down list.
7. Repeat steps 2 through 5: For the first
Device
drop-down list, select the AT-OMNI-324, and for the second
Device
drop-down list, select the AT-OMNI-311. When this macro is completed, it should appear similar to the following:
8. Click the
Save
icon, in the top-right portion of the
Room Macros
bar.
AT-OMNI-324 20
Basic Operation
Pairing and Unpairing Units
IMPORTANT:
Before pairing units, make sure to unpair (remove) any existing pairings using the
“unpair” macro that was created on page 19.
1. Click the
►
icon for the “Unpair” macro. This will remove any possible “out-of-the-box” (factory) pairing that may exist.
2. Click the
► icon for the “Pair” macro to pair the two units.
Example: Pairing two AT-OMNI-324 to a single AT-OMNI-311
The following illustration depicts an example of how to pair two AT-OMNI-324 units to a single AT-OMNI-311.
Refer to the instructions on the following page for how to configure this setup. Note that arbitrary IP addresses have been assigned for reference.
Laptop
USB
AT-OMNI-311
O
MNI
S TREAM
TM
192.168.11.127
PWR
LINK
HOST
SIGNAL
Ethernet
LAN
AT-OMNI-324
AT-OMNI-324
Ethernet
AT-OMNI-324
PWR
LINK
HOST
SIGNAL
O
S TREAM
TM
192.168.11.124
PWR
LINK
HOST
SIGNAL
O MNI
S
TM
192.168.11.123
Microphone
Web Cam
21
Basic Operation
1. In the
Room Macros
screen, click the icon, in the upper-right corner of the screen.
2. Enter “Unpair” for both the
Name
and
Macro Commands
text field.
3. Click the
+
icon to display the macro configuration dialog.
4. Click the
Device
drop-down list and select one of the devices from this list. Since the “Unpair” macro will be disconnecting a total of three units from one another, the “Unpair” macro will contain a total of three commands.
In this example, the AT-OMNI-324 is arbitrarily selected.
5. Click the
Command
drop-down list and select
Remove All Pairings
.
6. Repeat steps 3 through 5, selecting the second AT-OMNI-324 and then the AT-OMNI-311 from the
Device
dropdown list. When completed, the “Unpair” macro should appear as follows:
AT-OMNI-324 22
Basic Operation
9. Click the
Save
icon in the top-right portion of the
Room Macros
bar.
10. Create a “pairing” macro by clicking the icon, in the upper-right corner of the screen.
Note that since there are two AT-OMNI-324 units, creating the “Pair” macro can be achieved using two different methods: a. Create two separate macros: one to pair the AT-OMNI-311 and the AT-OMNI-324 with the camera, and another one to pair the AT-OMNI-311 with the AT-OMNI-324 with the speakerphone. This method provides more control, providing the option of which AT-OMNI-324 is paired with the AT-OMNI-311.
b. Create a single macro which pairs both AT-OMNI-324 units to the AT-OMNI-311. This method is more convenient, but does not provide the option of which AT-OMNI-324 is paired with the AT-OMNI-311.
For this example, two separate pairing macros will be created:
9. Enter “Pair to camera” in both the
Name
and
Macro Commands
text field. This macro will be used to pair the computer with the camera.
10. Click the
+
icon to display the macro configuration dialog.
11. Click the
Device
drop-down list and select the AT-OMNI-324 that is connected to the camera. In this example, the AT-OMNI-324 with the IP address of 192.168.11.124 will be selected.
12. Click the
Command
drop-down list and select
Pair (Auto)
.
13. Click the second
Device
drop-down list and select the AT-OMNI-311.
14. Repeat steps 10 through 13: select the AT-OMNI-311 in the first
Device
drop-down list, and then the AT-
OMNI-324 with the camera, from the second
Device
drop-down list. The “Pair to camera” macro should now appear as follows:
AT-OMNI-324 23
Basic Operation
9. Click the
Save
icon in the top-right portion of the
Room Macros
bar.
10. Click the icon, in the upper-right corner of the screen to create the final macro. This macro will be used to pair the computer with the speakerphone.
11. Enter “Pair to speaker” in both the
Name
and
Macro Commands
text field.
12. Click the
+
icon to display the macro configuration dialog.
13. Click the
Device
drop-down list and select the AT-OMNI-324 that is connected to the speakerphone. The AT-
OMNI-324 with the IP address of 192.168.11.123 will be selected
14. Click the
Command
drop-down list and select
Pair (Auto)
.
15. Click the second
Device
drop-down list and select the AT-OMNI-311.
16. Repeat steps 18 through 21: select the AT-OMNI-311 in the first
Device
drop-down list, and then the AT-
OMNI-324 with the speakerphone, from the second
Device
drop-down list. The “Pair to speaker” macro should now appear as follows:
17. Click the
Save
icon in the top-right portion of the
Room Macros
bar.
AT-OMNI-324 24
Basic Operation
DHCP Reset
Use the following instructions to reset the device to DHCP mode. Resetting to DHCP mode will not remove any pairings and if the device is already paired, it will remain paired.
1. Disconnect power from the unit.
2. Reconnect power to the unit, and within 5 seconds, press and hold the
PAIRING
button.
PAIRING button
AT-OMNI-324
DC 24V
UTILITY PAIRING
LAN
3. Continue holding the
PAIRING
button for 15 seconds, then release.
4. Power-cycle the unit once again, by disconnecting and reconnecting the power. Let the unit boot up normally.
O
MNI
S
TREAM
TM
LINK SIGNAL
5. The unit is now in DHCP mode and will automatically be assigned an IP address by the DHCP server, if one is present on the network.
AT-OMNI-324 25
advertisement
Related manuals
advertisement
Table of contents
- 8 Introduction
- 8 Features
- 8 Package Contents
- 9 Panel Description
- 10 Installation
- 10 Connection Instructions
- 10 Over a Network
- 10 Direct Connection
- 11 Connection Diagrams
- 12 Basic Operation
- 12 LED Indicators
- 13 Pairing
- 13 Using AMS
- 16 Manual Pairing
- 16 Unpairing an Extender
- 17 Using Velocity™
- 25 DHCP Reset
- 26 The AMS Interface
- 26 Device Info tab
- 27 Network tab
- 28 Pairing tab
- 29 Appendix
- 29 Mounting Instructions
- 30 Supported Cameras
- 31 Specifications