Installing CCD Camera Heads. Photometrics Photometric, Series 300 CE300, CH350, CH360, CH370

The Photometrics Series 300 CE300, Series 300 CH350, Series 300 CH360, Series 300 CH370 is an F-mount or C-mount, air- or liquid-cooled imaging system for acquiring digital scientific data. When the highest dynamic range is required, the Series 300 is the lowest noise, most sensitive camera system in the Photometrics line.

PDF Download
Document
Installing CCD Camera Heads. Photometrics Photometric, Series 300 CE300, CH350, CH360, CH370 | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • F-mount or C-mount
  • Air- or liquid-cooled
  • Digital scientific data acquisition
  • Highest dynamic range
  • Lowest noise
  • Most sensitive camera system

Frequently asked questions

Store the Series 300 camera system and the LCU in their original containers. To protect the system from excessive heat, cold, and moisture, store at an ambient temperature between -20°C and 50°C with a relative humidity of 0%–90% noncondensing.

The camera system’s ambient operating temperature is 0°C to 40°C with a relative humidity of 0%–80% noncondensing.

The charge-coupled device (CCD) and other system electronics are extremely sensitive to electrostatic discharge (ESD) and the optional liquid circulation unit requires periodic maintenance. To avoid permanently damaging the system, please observe the following precautions: * If you are using high-voltage equipment (such as an arc lamp) with your camera system, be sure to turn the camera power on last and power the camera off first. * If you have a liquid-cooled camera head, you MUST operate the LCU whenever the camera is on. * Use caution when triggering high-current switching devices (such as an arc lamp) near your system. The CCD can be permanently damaged by transient voltage spikes. If electrically noisy devices are present, an isolated, conditioned power line or dedicated isolation transformer is highly recommended. * Never connect or disconnect any cable while the camera system is powered on. An unconnected cable segment can become electrically charged and can damage the CCD if reconnected. * Always install the shorting plug on the camera head when the head is disconnected from its cable. * Do not connect the camera head cable to the camera head until the cable is first connected to the camera electronics unit (CEU). * Do not disconnect the camera head cable from the CEU until the cable is first disconnected from the camera head. * The system has been configured for 100V, 110V, 220V, or 240V AC input at 50/60 Hz. Do not connect your Series 300 system to a power source for which it was not configured or to a power source that has less than 1 kVA capacity. * Never impede airflow through the equipment by obstructing the air vents. Allow at least one inch air space around any vent. * Do not “mix and match” camera heads and CEUs. Refer to the Certificate of Performance supplied with your system for the serial numbers of the camera head and the electronics unit for this system.

Clean exterior surfaces of the camera system with a dry, lint-free cloth. To remove stains, contact Roper Scientific Customer Service.