Installation/Removal. Cabletron Systems FDDI, 7F06-02, 7F06-02 FDDI SmartSwitch
Advertisement
Advertisement
CHAPTER 3
INSTALLATION/REMOVAL
This chapter contains instructions for unpacking and installing the 7F06-2
Module in the:
• 7C03 MMAC SmartSwitch
• 7C04 Workgroup SmartSwitch
• 7C04-R Workgroup SmartSwitch
Also included in the chapter are instructions for installing the front panel
FPIMs.
3.1
UNPACKING THE 7F06-02 MODULE
Unpack the 7F06-02 Module by using the following steps:
Before unpacking the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
1. Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.)
2. Remove the module from the plastic bag. Observe all precautions to prevent damage from Electrostatic Discharge (ESD).
3. Carefully examine the module and check for damage. If damage exists, DO NOT install the module; contact Cabletron Systems Global
Call Center.
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-1
Chapter 3: Installation/Removal
3.2
INSTALLING FPIMS
Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
The 7F06-02 module is shipped without FPIMs. To install an FPIM, follow the procedure below:
1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.3.
2. Remove the blank front cover over the FPIM slot.
3. Install the FPIM as shown in Figure 3-1. Ensure that the rear connector
is seated firmly before tightening the two mounting screws.
Figure 3-1 Installing an FPIM
3-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Chapter 3: Installation/Removal
3.3
INSTALLING/REMOVING THE 7F06-02 MODULE
The following procedure details the installation and removal procedure for the 7F06-02 module.
3.3.1
Installing in the 7C03 SmartSwitch
The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch
using the following steps and referring to Figure 3-2.
Note: The left-most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module.
Note: Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the
7C03 must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.
2. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling.
3. Install the module by sliding it into slots as shown in Figure 3-2.
Ensure that the printed circuit board (PCB) is between the card guides, slides in straight, and engages the backplane connectors properly.
4. Using a slotted screwdriver, tighten the top and bottom screws.
CPU
SN
Card
Guides
Figure 3-2 Installing the 7F06-02 Module in the
7C03 MMAC SmartSwitch
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-3
Chapter 3: Installation/Removal
3.3.2
Removing from the 7C03 SmartSwitch
The 7F06-02 Module inserted in the 7C03 MMAC SmartSwitch can be removed upon proper removal of power. Follow the steps below and refer
to Figure 3-3 to remove the module.
Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the
7C03 must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.
2. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis.
3. Locate the two ejector tabs on the module (to the right of the screws on the top and bottom of the module).
4. Simultaneously press down on the bottom ejector tab and up on the top ejector tab until the module ejects from the backplane.
5. Grasp both ejector tabs and carefully slide the module out of the chassis.
SN
CPU
Screw
Ejector Tab
Screw
Ejector Tab
3-4
Figure 3-3 Removing the 7F06-02 Module from the 7C03 MMAC
SmartSwitch
7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Chapter 3: Installation/Removal
3.3.3
Installing in the 7C04 or 7C04-R Workgroup
SmartSwitch
The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup
SmartSwitch using the following steps and referring to Figures 3-4 and
3-5.
Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.
The bottom slot in the 7C04-R Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.
Therefore, before installing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum, the
7C04 or 7C04-R must be pulled to disconnect it from the power source. Damage to modules may result if this procedure is not followed.
2. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling.
3. Install the module by sliding it into slots as shown in the appropriate figure. Ensure that the printed circuit board (PCB) is between the card guides, slides in straight, and engages the backplane connectors properly.
4. Using a slotted screwdriver, tighten the top and bottom screws.
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-5
Chapter 3: Installation/Removal
1
2
SN
3
4
Screw
Ejector Tab
Figure 3-4 Installing the 7F06-02 Module in the 7C04 Workgroup
SmartSwitch
3
2
1
4
FANS
Card
Guides
3-6
Figure 3-5 Installing the 7F06-02 Module in the 7C04-R Workgroup
SmartSwitch
7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Chapter 3: Installation/Removal
3.3.4
Removing the 7F06-02 from the 7C04 or 7C04-R
Workgroup SmartSwitch
The 7F06-02 Module, inserted in the 7C04 or the 7C04-R
Workgroup SmartSwitch, can be removed whenever necessary. Follow the steps below and refer to Figures 3-6 or 3-7 to remove the module.
Note: Before removing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
1. As a precaution, power down the MMAC 8 before beginning the installation or removal of any modules. At the very minimum the 7C04 or 7C04-R must be pulled to disconnect it from the power source.
Damage to modules may result if this procedure is not followed.
2. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis.
3. Locate the two ejector tabs on the module (below the screws on the left and right end of the module).
4. Simultaneously press left on the left ejector tab and right on the right ejector tab until the module ejects from the backplane.
5. Grasp both ejector tabs and carefully slide the module out of the chassis.
Screws
3
4
1
2
Ejector Tabs
Figure 3-6 Removing the 7F06-02 Module from the 7C04 Workgroup
SmartSwitch
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 3-7
Chapter 3: Installation/Removal
Screws
3
2
1
4
FANS
SN
Ejector Tabs
Figure 3-7 Removing the 7F06-02 Module from the 7C04-R Workgroup
SmartSwitch
3-8 7F06-02 FDDI SmartSwitch Interface Module User’s Guide