Advertisement
Advertisement
CHAPTER 4
TROUBLESHOOTING
4.1
DIAGNOSTIC AND MONITORING SYSTEM
The 7F06-02 Module uses LANVIEW, Cabletron Systems’ built-in visual diagnostic and status monitoring system.
With LANVIEW LEDs the status of each transmit and receive port on the
7F06-02 Module can be determined, at a glance. This section discusses the function and purpose of the LEDs on the 7F06-02 Module.
Figure 4-1 shows the LANVIEW LEDs of the 7F06-02 Module.
7F06-02
SP
Primary
Ring
Secondary
Ring
A
F
D
D
I
1
P
S
A
B
B
A Link Status
B Link Status
Receive
Transmit
Figure 4-1 LANVIEW LEDs
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4-1
Chapter 4: Troubleshooting
4.2
PORT RECEIVE LEDS
Table 4-1 indicates the state of the receive port.
LED Color
Yellow (Flashing)
Off
Table 4-1 Port Receive LEDs
State
Data activity (flashing to steady on indicates rate)
No activity, port can be disabled or enabled
4.3
PORT TRANSMIT LEDS
Table 4-2 indicates the state of the transmit port.
LED Color
Green (Flashing)
Off
Table 4-2 Port Transmit LEDs
State
Data activity (flashing to steady on indicates rate)
No activity, port can be disabled or enabled
4.4
A/B LINK LEDS
Table 4-3 indicates the state of the A/B Link LEDs.
A P
Green N/A
Green Green
Green Green
Table 4-3 Link LEDs
S B State
N/A
Off
Green Ports Enabled & Active
Green THRU A, MAC on Primary,
Secondary Bypasses Board
Yellow Green THRU A, MAC on Primary,
No MAC on Secondary
4-2 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Chapter 4: Troubleshooting
A
Green
Green
Green
Green
Off
P
Green Green
Green Yellow
Yellow Green
Yellow Yellow
Green Green
Green Off
Green Red
Yellow Off
Red
Yellow
Yellow
Off
Off
Table 4-3 Link LEDs (Continued)
S B State
Red
Red
Red
Off
Red
Off
Green Green THRU B, MAC on Secondary,
Primary Bypasses Board
Green Green THRU B, MAC on Secondary,
No MAC on Primary
Off Green THRU, No MAC on Primary,
Secondary Bypasses Board
Yellow Green THRU, No MAC on Secondary,
Primary Bypasses Board
Red
Red
Yellow
Yellow
WRAP A, MAC on Primary
WRAP A, No MAC on Primary
Off
Green
Green
Green
Green
Green
WRAP B, MAC on Primary
WRAP B, No MAC on Primary
WRAP AB, MAC on Primary
BYPASS Primary & Secondary
Yellow PCM did not complete, Not
Red
TWISTED A-A, B-B
Active
Ports Disabled
7F06-02 FDDI SmartSwitch Interface Module User’s Guide 4-3
Chapter 4: Troubleshooting
4-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide