Conventional Fire Panel
7
7.1
Appendix
Appendix | en 65
Brief Overview, Operating Level 1 and 2
Submenu
1 2
Menu operating level 1 and 2 i
1 Current
Events
1 Faults
2 Disablements
3 Test
4 PreAlarm
1 Event History 2 History
2 Test History
3 Alarm Counter -
4 System Info 1 SW Release
-
-
-
3
-
-
-
-
-
-
-
-
2 Operation Days -
Menu operating level 2 – code required i
5 View Config -
6 System Config 1 Date/Time
2 Keypad Tone
-
1 On
2 Off
3 Language 1 1-A - L
2 2-M - Z
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
66 en | Appendix Conventional Fire Panel
7.2
Test menu
Submenu
1
Test menu
1 Test MMI
2 Test Zones
2 3
3 Dis/Enable
2014.06 | 7.0 | F.01U.172.980
-
1 Zone 1
2 Zone 2
3 Zone 3
4 Zone 4
5 Zone 5
6 Zone 6
7 Zone 7
8 Zone 8
1 Zones
2 NAC
3 Relays
4 All
- -
- -
- -
- -
- -
- -
- -
- -
- -
1 Zone 1
2 Zone 2
3 Zone 3
4 Zone 4
5 Zone 5
6 Zone 6
7 Zone 7
8 Zone 8
ACK =YES ESC=No
ACK =YES ESC=No
ACK =YES ESC=No
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel Appendix | en 67
7.3
Brief Overview, Operating Level 3
Submenu
1
1 - System Config
1 1 Date/Time
2 Keypad Tone
2 3
3 EOL Devices
4 Zone Reset
5 Aux Power
6 Faults
1 On
2 Off
1 Resistor
- -
- -
- -
2 Only 2W Module - -
3 With 4W Module - -
1 Cut For 1 1 s
2 5 s
2 Stabilize For
3 10 s
4 15 s
5 20 s
1 1 s
2 5 s
3 10 s
1 With Zone
2 With Panel
3 Never
1 Latching
- -
- -
- -
4 15 s
5 20 s
- -
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
68 en | Appendix Conventional Fire Panel
Submenu
1
7 Code
8 Test History
2
2 Non Latching
1 Level Code 2
2 Level Code 3
1 Log Enabled
2 Log Disabled
Submenu
1
2 - Delay Config
2
2 1 Day Mode Off 1 Manual
2 Automatic
2 Alarm Verific 1 ACK Within
2014.06 | 7.0 | F.01U.172.980
2 Invest Time
3
3
- -
- -
- -
- -
- -
- -
Off Time: : 17:00
1 30 s
2 60 s
3 90 s
4 120 s
1 1 min Delay
2 2 min Delay
3 3 min Delay
4 4 min Delay
5 5 min Delay
6 6 min Delay
7 7 min Delay
8 8 min Delay
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel Appendix | en 69
Submenu
1
3 Int Alarm Stor
2 Zone 2
Bosch Sicherheitssysteme GmbH
2
3 NAC 1
1 Reset After
4 Power Fault
2 Total Delay
1 No Delay
2 1 min Delay
3 5 min Delay
4 10 min Delay
5 15 min Delay
Submenu
1
3 - Zone Config
3 1 Zone 1
2
- -
- -
- -
3
1 Alert
2 Evacuate
1 1 s
2 5 s
3 10 s
4 15 s
5 20 s
- -
- -
- -
3
1 No Delay
2 Int Alarm Stor
3 Alarm Verific
4 2-Det Depend
5 2-Zone Depend - -
1 No Delay - -
- -
- -
- -
- -
2014.06 | 7.0 | F.01U.172.980
70 en | Appendix Conventional Fire Panel
Submenu
1
3 Zone 3
4 Zone 4
5 Zone 5
6 Zone 6
7 Zone 7
8 Zone 8
4 - Input Config
4 1 Input 1
2 3
No Delay (FPC‑500‑4 /-8)
No Delay (FPC‑500‑4 /-8)
No Delay (FPC‑500‑8)
No Delay (FPC‑500‑8)
No Delay (FPC‑500‑8)
No Delay (FPC‑500‑8)
2 Input 2
Submenu
1
5 - Output Config
5 1 NAC
2
2014.06 | 7.0 | F.01U.172.980
1 Not Used
2 Drill/Evacuate
3 Silence
4 Level 2
5 Reset Panel
6 Ext PS Fault
7 Ext Batt Fault - -
See Input 1 (FPC‑500‑8)
- -
- -
- -
- -
- -
- -
3
1 NAC Zones 1
2 NAC Zones 2
3 Reactive NAC
- -
- -
1 By Other Zone
2 No Reactivate
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel
Submenu
1 2
4 NAC in test
2 Alarm Relay 1 Silencable
2 Drillable
3 OC/Relay Ext 1 OC/Relay 1
2 OC/Relay
3 OC/Relay
4 OC/Relay
5 OC/Relay
6 OC/Relay
7 OC/Relay
8 OC/Relay
Appendix | en 71
3
1 Activation
2 No Activation
1 Silencable
2 Not Silencable
1 Drillable
2 Not Drillable
1 Zone = Alarm
2 Zone Normal
3 Sum Alarm
4 Sum PreAlarm
5 Sum Fault
6 Sum Disable
7 Sum Test
8 Not Used
See OC/Relay 1
See OC/Relay 1
See OC/Relay 1
See OC/Relay 1
See OC/Relay 1
See OC/Relay 1
See OC/Relay 1
6 - View Config
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
72 en | Appendix Conventional Fire Panel
Submenu
1
7 - Output Control
7 1 NAC 1
2 NAC 2
3 Alarm Relay
4 Fault Relay
5 OC/Relay Ext
2
3 OC/Relay 3
4 OC/Relay 4
5 OC/Relay 5
6 OC/Relay 6
7 OC/Relay 7
3
ACK =On ESC=Off - -
ACK =On ESC=Off - -
ACK =On ESC=Off - -
ACK =On ESC=Off - -
1 OC/Relay 1 ACK =On ESC=Off
2 OC/Relay 2 ACK =On ESC=Off
ACK =On ESC=Off
ACK =On ESC=Off
ACK =On ESC=Off
ACK =On ESC=Off
ACK =On ESC=Off
6 All
8 - Config Reset
Navigation in the menu
8 OC/Relay 8 ACK =On ESC=Off
ACK =On ESC=Off - -
Press the arrow key to scroll up in the menu.
i
Press the arrow key to scroll down in the menu.
Press the ACK key to confirm your selection.
ACK
2014.06 | 7.0 | F.01U.172.980
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel Appendix | en 73
RESET
RESET
ESC
ESC
1
...
8
Press the ESC key to exit the selection without making a change or to jump up a menu level.
Hold the ESC key down for 2 seconds to jump to the uppermost menu level.
In the menu, each menu item has a number from 1 to 8 preceding it. Use the zone keys to select the desired menu item in the menu.
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
74 en | Appendix Conventional Fire Panel
7.4
Default Settings
Menu item
1 System Config
2 Keypad Tone
3 EOL Devices
4 Zone Reset
1 Cut For
2 Stabilize For
5 Aux Power
6 Faults
8 Test History
2 Delay Config
1 Day Mode Off
2 Alarm Verific
1 ACK Within
2 Invest Time
3 NAC 1
3 Int Alarm Stor
3 Zone Config
1 Reset After
4 Power Fault
1 Zone 1
...
4 Input Config
2014.06 | 7.0 | F.01U.172.980
1 min
Evacuate
10 s
No Delay
No Delay
Default setting
On
Resistor
5 s
5 s
With Zone
Latching
Log Enabled
Manual
60 s
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel Appendix | en 75
Menu item
1 Input 1
...
5 Output Config
1 NAC
1 NAC Zones
2 NAC Zones
Default setting
Not Used
All zones
3 Reactive NAC By Other Zone
4 NAC in test
2 Alarm Relay
1 Silencable
2 Drillable
3 OC/Relay Ext
1 OC/Relay 1
All zones
No Activation
Not Silencable
Not Drillable
Zone = Alarm
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
76 en | Appendix Conventional Fire Panel
7.5
Event Memory
Message Meaning
Drill/Evacuate A manual alarm has been triggered on the panel.
Zone Alarm Zone # has triggered an alarm.
Zone PreAlarm Zone # has triggered a pre-alarm.
Zone Open
Zone Short
Zone # is interrupted.
Zone # has a short-circuit.
Zone Normal Zone # is in the normal state. (Fault or alarm eliminated)
Zone Disabled Zone # was enabled.
Zone Enabled
Input Open
Input Short
Input Normal
Aux Power
Short
Aux Power
Normal
NAC Open
NAC Short
NAC Normal
NAC Enabled
NAC Disabled
Zone # was enabled.
Input # interrupted.
Input # short-circuit.
Input # normal.
Short-circuit in the AUX power supply
Error in the AUX power supply eliminated.
Notification appliance #, line interrupted
Notification appliance #, short-circuit on line.
Notification appliance # normal. (Fault was eliminated)
Notification appliances re-enabled.
Notification appliances disabled.
2014.06 | 7.0 | F.01U.172.980
Bosch Sicherheitssysteme GmbH
Conventional Fire Panel Appendix | en 77
Message Meaning
Relays Enabled Relays re-enabled.
Relays Disabled Relays disabled.
Battery Fault Fault in the battery power supply.
Battery Restore Battery power supply was restored.
Mains Fault Fault in the 230 V power supply.
Mains Restore 230 V power supply was restored.
Ext PS Fault Fault in external power supply unit.
Ext PS Normal Fault in external power supply unit resolved.
Ext BATT Fault Fault in external battery.
Ext BATT
Normal
Fault in external battery resolved.
Sys Load Fault Current consumption of panel and all connected peripherals is above 3.5 A.
Sys Load
Normal
Current consumption is back in permitted range.
System Fault
Panel boot-up
Reset Panel
Night Mode
Day Mode
Earth Fault
Earth Normal
Level Enter
Level Exit
System fault
Panel has been restarted.
Panel has been reset.
Panel has switched to night mode.
Panel has switched to day mode.
Grounding fault.
Fault in grounding resolved.
Operating level # entered.
Operating level # exited.
Bosch Sicherheitssysteme GmbH 2014.06 | 7.0 | F.01U.172.980
78 en | Appendix
7.6
Conventional Fire Panel
Message
Silenced
Unsilenced
Meaning
An alarm has been silenced.
A silenced alarm has been reactivated.
Test Memory Messages
Message
Zone Start
Zone Test
Zone End
Meaning
Zone # set to test mode.
Zone # successfully tested.
Zone # test mode exited.
2014.06 | 7.0 | F.01U.172.980