Approved applications. Bosch B5512, Radion B810, B4512, B3512
The Bosch B5512, B4512, and B3512 Control Panels are designed for use in security systems. These panels offer a range of features, including multiple areas, points, outputs, and communication options. You can connect to the control panel using a network connection, or locally using the control panel’s on-board Ethernet port or USB port.
Advertisement
Advertisement
Control Panel Approved applications | en 91
18
18.1
18.1.1
18.1.2
Approved applications
The UL System Chart references the components that are evaluated and listed by UL for compatibility with B5512/B4512/B3512 control panels. These components meet the basic system requirements for the applicable standard.
Refer to Compatible UL listed components, page 97.
The system wiring diagrams show the relationship between the control panel and the accessory components.
Refer to System wiring diagrams, page 80.
Optional compatible equipment
You can use UL Listed components not requiring evaluation for electrical compatibility in many applications when installed according to the manufacturer’s instructions.
Burglar applications
You can use UL Listed components not requiring evaluation for electrical compatibility in burglary applications. In some cases, you must use a UL Listed interface module with the sensors. Consult the individual component specification and installation documents to determine suitability.
Bank Safe and Vault applications
You must use the UL Listed Model 5110 Bell and Model 4001-42 External Line Balancer (both made by Rothenbuhler) for the bell and balanced line module in bank safe and vault applications. Modify the D8108A Attack-Resistant Enclosure to meet UL Standard 681.
Refer to Wiring Information for installations using the Rothenbuhler 5110/4001-42 High
Security Bell for wiring instructions and diagrams.
Control panel enclosure requirements
UL Standard 681 for Installation and Classification of Mercantile and Bank Burglary Alarm
Systems requires foil lining or equivalent protection of the control unit enclosure. The D8108A
Attack-Resistant Enclosure does not have a foil lining, but acceptable protection is provided by mounting electronic vibration sensors inside the enclosure.
Notice!
Do not use proximity alarms (capacitance) to protect the control panel enclosure.
!
– Install the same electronic vibration sensors in the D8108A that are used to protect the safe or vault.
– Mount the Sentrol 5402, Potter EVD-S, or Arrowhead S-3810 electronic vibration detection (EVD) system inside the D8108A to meet the UL 681 requirements.
– Install and test the EVD sensor according to the manufacturer’s instructions.
– Mount the EVD sensor directly inside the metal cabinet of the D8108A.
Caution!
Do not install the EVD sensor within 6.4 mm (0.25 in) of the components or traces of the printed circuit assembly.
Battery connections
– Using a D122 Dual Battery Harness, connect two 12 V 7 Ah batteries in the control panel enclosure.
Bosch Security Systems, Inc.
Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180
92 en | Approved applications Control Panel
– Use a separate D8108A for the two 12 V 7 Ah batteries. When using a D122L Dual Battery
Harness, wire the batteries in parallel and connect the harness to the BAT+ and BATterminals of the control panel.
Bell requirements
Use the following Rothenbuhler bell and balanced line modules with the control panel:
– UL Listed Model 5110 Bell
– UL Listed Model 4001-42 External Line Balancer
Wiring Information for installations using the Rothenbuhler 5110/4001-42 High Security Bell
Refer to the following two figures for wiring information.
2 1
1 3 6
0.64 mm (0.25 in) minimum distance
4 5
8
7
9
10
15
13
14
11
12
9
+ + -
11
16
Figure 18.1: Rothenbuhler 5110 4001-42 High Security Bell to control panel wiring
Callout ᅳ Description
1 ᅳ Self-contained UL listed vibration sensor
2 ᅳ Control panel
3 ᅳ Accessory modules
4 ᅳ High line security module)
5 ᅳ 4001-42 Balanced Line Module
6 ᅳ 5110 bell
7 ᅳ D133 Relay
Callout ᅳ Description
9 ᅳ D122/D122L Dual Battery Harness
10 ᅳ D126 Battery
11 ᅳ D8108A Enclosure
12 ᅳ Proximity/control unit
13 ᅳ Normally open (NO)
14 ᅳ Normally closed (NC)
15 ᅳ End-of-line (EOL) resistor
2
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.
Control Panel Approved applications | en 93
Callout ᅳ Description
8 ᅳ Alarm input point 1
Callout ᅳ Description
16 ᅳ Safe
1 Use Terminals 1 through 8. (Select only one.)
2 Use a D113 Battery Lead Supervision Module to supervise the battery connections
.
Bosch Security Systems, Inc.
Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180
94 en | Approved applications
1
13
12
1 2 3
14
6
Control Panel
3
COMMUNICATION MODULE 1
100BASE-T
ETHERNET
18 VAC
LINK
USB
P1
COM AUX
OUTPUT A
AUX
- 12 V +
SDI2
Device Bus
R Y G B
ON-BOARD POINTS
Voltage Ranges
Open
Normal
Short
3.7 - 5.0 VDC
2.0 - 3.0 VDC
0.0 - 1.3 VDC
1 k End of Line Resistors
C
OUTPUT
B
1 COM 2 3 COM 4 5 COM 6 7 COM 8
18VAC
1
2
3
2
R E D O R G W H T B L K
4
4
+ BAT -
NO C NC
OUTPUT A
COM AUX R Y G B
PWR A B COM
1 COM 2 3 COM 4 5 COM 6 7 COM 8
6
9 8
7
9
11
N/O 1
COMM 1
N/C
X1 -
X1+
10 9
5
Figure 18.2: Detailed Rothenbuhler 5110_4001-42 High Security Bell to control panel wiring (B5512 shown)
Callout ᅳ Description
1 ᅳ 5110 Logic Board
2 ᅳ 4001-42 External Line Balancing Module
3 ᅳ Control panel set to OUTPUT A using AUX
PWR
4 ᅳ Alarm output
5 ᅳ Alternate alarm (use B or C)
6 ᅳ Common
7 ᅳ +12.0 VDC
* Use Terminals 1 through 8. (Select only one.)
Callout ᅳ Description
8 ᅳ Alarm input point*
9 ᅳ 10 kΩ resistor
10 ᅳ Optional silence switch
11 ᅳ D133 Relay Module
12 ᅳ BBL In 4
13 ᅳ BBL Out 5
14 ᅳ Terminal TB1
Notice!
Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault applications.
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.
Control Panel
18.1.3
Approved applications | en 95
System configuration requirements
The following configuration and programming options are required for UL Bank Safe and Vault
Systems. Refer to RPS Help or the control panel's Program Entry Guide for programming information.
Safe and Vault protective circuits
To test the devices that protect the safe(s) or vault(s) without sounding the bell, specify the devices’ points as controlled zones and supervised for trouble conditions. Refer to Point Index in RPS Help or the control panel's Program Entry Guide more information.
Bell configuration
– UL 365 requires a bell time of 15 to 30 min. The Rothenbuhler 5110 Bell provides selectable bell time through manipulation of its jumpers. Refer to the manufacturer’s installation instructions for more information.
– In addition to the jumper settings inside the bell, you can activate the control panel for a bell time of 15 min.
– UL 365 requires a Bell Test at arming and you must enable it in control panel programming.
– Refer to Bell Parameters in RPS Help or the control panel's Program Entry Guide for more bell time and test programming information.
Bell test
– To enable the bell test feature, you enable an unused area of the control panel. Enable the bell test feature for the unused area only. Program OUTPUT B as the area bell output for the unused area.
– Make all passcodes with authority to arm the safe or vault and also send a Closing Report valid in this area. Program the area for a five-second exit delay.
– To complete the installation for this feature, connect the output to a D134 Dual Relay
Module.
Exit delay
Do not program the control panel’s maximum exit delay longer than 30 seconds.
Fire applications
You can use UL Listed fire initiating devices not requiring electrical compatibility evaluation in any application. For example, the four-wire smoke detectors, heat detectors, waterflow switches, and manual pull stations are suitable fire initiating devices. Consult the individual component specification and installation documents to determine suitability.
Notice!
UL requires that the control panel supervises any device powered from a power output.
Notice!
The control panel does not support multiple detectors in alarm. The control panel is compatible with detectors with optional features. Do not mix detectors from different manufacturers on the same circuit.
Four-wire smoke detectors
When using four-wire smoke detectors, install a power supervision device according to the manufacturer’s instructions. You can connect any number of four-wire smoke detectors to the control panel (subject to available auxiliary power).
Bosch Security Systems, Inc.
Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180
96 en | Approved applications
18.1.4
18.2
Control Panel
The Reset Sensor command is available from the keypads when the Reset Sensor is enabled.
Connect the smoke detectors to a suitable interface such as the B208 Octo-input Module or on-board point to meet UL and NFPA requirements.
Notification Appliance Circuit (NAC)
Refer to Notification appliance circuit wiring, page 84.
Notice!
Test Weekly: Perform a Fire Test weekly.
Further information
–
Standby battery calculations, page 98
–
Household Fire Warning equipment, page 101
Enclosures
Mount the control panel assembly in any of the Bosch Security Systems, Inc. enclosures listed:
– B10 Medium Control Panel Enclosure
– B11 Small Control Panel Enclosure
– D2203 Enclosure
– D8103 Universal Enclosure*
– D8109 Fire Enclosure (red)*
– D8108A Attack Resistant Enclosure*
*Requires a B12 mounting bracket.
B10, B11, D2203, and D8103 enclosures
The B10, B11, D2203, and D8103 enclosures are suitable for residential fire and burglary installations and commercial burglary applications that do not require attack resistance or the approval by Factory Mutual (FM) or New York City – Materials and Equipment Acceptance
(NYC-MEA). Refer to Compatible UL listed components, page 97 for acceptable applications.
D8108A Enclosure
The D8108A is attack resistant and intended primarily for UL commercial burglar alarm and mercantile safe and vault applications requiring a local bell. Use this enclosure in any burglar or fire alarm application where the D8109 Enclosure is suitable.
The D8108A, with some modification, can be used for bank safe and vault applications. UL lists the D8108A for all commercial fire alarm applications. It is approved by FM, CSFM, and the NYC-MEA.
D8109 Red Fire Enclosure
Generally, the D8109 is used for fire alarm applications. It is approved by FM, CSFM, and the
NYC-MEA.
B12 Mounting Plate for D8103 Enclosure
The mounting plate is compatible with the D8103, D8108A, and D8109 Enclosures.
Combination fire and intrusion alarm systems
A system can include a combination of fire and intrusion devices on any bus or module.
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.
Control Panel Approved applications | en 97
18.3
Compatible UL listed components
Minimum Hours of Standby
Battery
B10 Medium Control Panel
Enclosure
B11 Small Control Panel
Enclosure
B201 2-wire Powered Loop
Module
B208 Octo-input Module
B308 Octo-output Module
B426 Conettix Ethernet
Communication Module
B430 Plug-in Telephone
Communicator
B440 Conettix Plug-in
Cellular Communicator
B441 Conettix Plug-in CDMA
Cellular Communicator
B442 Plug-in GPRS Cellular
Communicator
B443 Plug-in HSPA+ Cellular
Communicator
B450 Conettix Plug-in
Communicator Interface
B520 Auxiliary Power Supply
Module
B810 RADION receiver SD
B820 SDI2 Inovonics
Interface Module
B915 Basic Keypad
B920 Two-line Alphanumeric
Keypad (SDI2)
4
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Househol d
Burglary
Household
Fire
Household
Fire/ Burglary
Combined
Central
Station
Burglary/
Proprieta ry
24 + 4 min alarm 4
Police
Connecte d
Burglary
Local
Burglary
4 4
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
Holdup
8
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Bosch Security Systems, Inc.
Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180
98 en | Approved applications Control Panel
B921C/B921CW Two-line
Capacitive Keypad
1+ 1+ 1+
B930 keypads
B942/B942W Touch Screen
Keypad
1+
1+
1+
1+
1+
1+
CX4010 Plug-in Transformer
(18 VAC 22 VA 60 Hz)
Required for all applications.
D125B Dual Class B Initiating
Module
Opt.
Opt.
Opt.
D126 Standby Battery (12 V,
7 Ah)
Opt.
D130 Auxiliary Relay Module Opt.
Opt.
Opt.
Opt.
Opt.
D133 Single Relay Module
D134 Dual Relay Module
D1218 Battery (12 V, 18 Ah) Opt.
D192G Class “B”, Style Y
Bell Circuit Supervision
D8004 Transformer
Enclosure
D8108A Attack Resistant
Enclosure or D8109 Fire
Enclosure
D8108A Attack Resistant
Enclosure 1
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Req.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
1+
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
No
Opt.
1+
1+
1+
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Key
No
Req.
Opt .
1+
Not acceptable for this application.
Required for this application.
Optional for this application.
1 or more required for this application. Consult the appropriate standard.
1 For commercial applications using the B430, and when doing local or police station connect applications, the
D8108A Enclosure is required for all applications.
* Not investigated by UL.
18.4
Standby battery requirements and calculations
Standby battery calculations
UL 365 requires 72 hr of standby battery capacity. Limit the auxiliary power current for all devices, including keypads, to 80 mA or less to meet this requirement.
A
AC Power On Normal
Current (mA)
B
AC Power Off Minimum
Current (mA)
C
In Alarm Maximum
Current (mA)
Opt.
Opt.
Opt.
Opt.
Opt.
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.
Control Panel Approved applications | en 99
Model Number Qty
Used
B5512/B4512/
B3512
______
B201
B208
B308 1
B426
B430
B440
B441
B442
B443
B450 2
B520
B810
B820
B915
B920
B921C
B930
B942 3
D125B
D127
D129
D132A
D133 4
D134 5
D185
D192G
____
____
____
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
______
Bosch Security Systems, Inc.
Each
Unit
125
18
35
22
100
5
35
35
35
35
30
15
100
100
35
35
45
35
200
25
5
23
10
245
35
Qty x 1
Total
= 125 x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x 1 x 1
= ______
= ______ x 1 x 1 x 1
= ______
= ______
= ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______
_____ x Qty = ______
Each
Unit
125
18
35
22
100
5
35
35
35
35
30
15
100
100
35
35
45
35
200
25
5
23
10
245
35
Ratings of other devices in the system that are not shown above:
____ ______ _____ x Qty = ______ ______
______
Qty x 1 x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x 1 x Qty x Qty x Qty x Qty x Qty x Qty x 1 x 1 x 1 x Qty x Qty x Qty x Qty x Qty
Total
= 125
= ______
= ______
_____ x Qty = ______
_____ x Qty = ______
______
______ x Qty x Qty
Installation and System Reference Guide
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= 35
= 35
= 35
= 35
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
= ______
Each
Unit
155
168
55
25
70
300
100
110
70
70
85
80
300
150
150
150
30
15
100
35
35
22
100
25
150
Qty x 1
Total
= 155 x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x Qty = ______ x 1 = ______ x 1 = ______ x 1 x 1 x 1
= ______
= ______
= ______ x Qty = ______ x Qty = ______ x Qty = ______
____ x Qty = ______
____ x Qty = ______
____ x Qty = ______
____ x Qty = ______
2014.05 | 11 | F.01U.287.180
100 en | Approved applications Control Panel
Total A = ______ Total B = ______
1 The In Alarm calculation for the B308 is: 20 x Qty + (16.25 x number of relays).
2 Currents listed are for the B450 only. Include plug-in device currents in calculations.
3 If using the proximity reader, add 100 mA to columns A, B, and C before calculating.
4 38 mA for each active relay.
5 Value = Minutes of alarm operation/60
Table 18.1: Current rating chart for standby battery calculations
Total C = ______
Contingency
15%
Total Ah
= _________
3 Total B 1 Hours
( ________ x 24 ) +
Total C 1
( ________ x
Alarm Operation
0.083)
2
1 Refer to previous table.
2 Value = Minutes of alarm operation/60
3 Total Ah requirements must not exceed the Ah capacity of batteries:
– One D126 Battery = 7 Ah
– Two D126 Batteries = 14 Ah
– One D1218 Battery = 18 Ah
Table 18.2: General ampere-hour (Ah) calculation formula
+
Application
Residential Burglary
Proprietary Burglary
Central Station (Bank)
Central Station (Mercantile)
Police Station Connected (Bank)
Police Station Connected (Mercantile)
Local Burglary (Bank)
Local Burglary (Mercantile)
Holdup
Residential Fire
Table 18.3: Minimum standby and alarm times
Minimum Required
Standby Time (hr)
4
4
72
4
72
24
72
24
8
24
Minimum Alarm Time (min)
4
N/A
N/A
N/A
30 (CUL)/15 (UL)
30 (CUL)/15 (UL)
30 (CUL)/15 (UL)
30 (CUL)/15 (UL)
N/A
5 (CUL)/4 (UL)
Type
Household Burglary and
Commercial Burglary
Required capacity
4 h
Bank Safe and Vault 72 h (UL 365). Auxiliary power current for all devices, including keypads, must be limited to 80 mA or less to meet this requirement.
Table 18.4: Standby battery requirements
Calculations
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.
Control Panel Approved applications | en 101
Notice!
Because of changing regulations, verify the necessary time with your local authority having jurisdiction (AHJ).
18.4.1
Household Fire Warning equipment
The Household Fire Warning Equipment Standard requires 24 h of standby current plus 4 min of alarm operation at the end of the 24-hour period. Use battery Ah calculations to confirm compliance. The formula shown below includes the calculation for 4 min of alarm operation at the end of the 24-hour period, and a 15% contingency factor that allows for depletion of battery capacity with age.
Notice!
Because of changing regulations, verify the necessary time with your local authority having jurisdiction (AHJ).
Total B 1 Hours Total C 1 Alarm Operation 2
( ________ x 24 ) + ( ________
–
–
1
Refer to previous table.
2
Value = Minutes of alarm operation/60
3
Total Ah requirements must not exceed the Ah capacity of batteries:
–
One D126 Battery = 7 Ah
Two D126 Batteries = 14 Ah
One D1218 Battery = 17.2 or 18 Ah x 0.083)
Table 18.5: Household fire ampere-hour (Ah) calculation formula
+
Contingency
15%
Total Ah
= _________
3
18.5
UL 365 - Police Station Connected Burglar Alarm Units and
Systems
In a mercantile burglar alarm system, a mercantile alarm sounding device located within a building but outside the protected area, is acceptable, provided it is rated for outside service and alarm conditions are transmitted to:
– The dispatch location of the law enforcement agency having jurisdiction over the protected property or
– A central station or residential monitoring station complying with the Standard for
Central-Station Alarm Services, UL 827.
In a mercantile burglar alarm system, an alarm sounding device located within the area of greatest protection, or outside the area of greatest protection but within an area protected by an alarm system and that shares a common control unit with the system installed in the area of greatest protection, is acceptable provided it is rated for inside service and alarm conditions are transmitted to:
– The dispatch location of the law enforcement agency having jurisdiction over the protected property or
Bosch Security Systems, Inc.
Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180
102 en | Approved applications
18.6
18.7
Control Panel
– A central station or residential monitoring station complying with the Standard for
Central-Station Alarm Services, UL 827.
An inside sounding device shall be mounted at least 10 feet (3.05 m) above the floor or at the surface of the ceiling. When there is a fixed construction within the area that could provide access for an intruder, the alarm sounding device shall also be mounted at least 4 ft (1.2 m) as measured horizontally, away from the edges of the fixed construction or at least 10 ft (3.05 m) above it so as to minimize access by an intruder.
UL 636 - Holdup Alarm Units and System
Refer to Required Programming to meet UL636 in RPS Help or the control panel's Program Entry
Guide.
ULC
Conduct testing monthly, with the primary de-energized.
2014.05 | 11 | F.01U.287.180
Installation and System Reference Guide Bosch Security Systems, Inc.

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Supports multiple areas
- Offers various communication options
- Provides a range of points for protection
- Includes on-board outputs for controlling devices
- Allows for expansion with optional modules
- Can be programmed using a keypad or Remote Programming Software (RPS)