The DSC GS3055-IG is a wireless communicator that sends alarm system information to a System III or System II receiver via a GSM/GPRS wireless network. With simulated landline mode, it switches to the GSM network if the landline fails. The device provides 4 programmable outputs, a case tamper output, and land-line over-voltage protection. Its dual-band GSM radio operates on 850/1900MHz frequency, and the internal event buffer can store up to 256 events. Compatible with 4 or 10-digit Contact ID, it features GPRS/Internet communication with Sur-Gard System III/II.
advertisement
▼
Scroll to page 2
of
12
GS3055-I GSM-GPRS INTERFACE INSTALLATION MANUAL WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Table of Contents INTRODUCTION ........................................................................................................ 1 FEATURES ................................................................................................................ 1 Technical Specifications ........................................................................................... 1 Ratings .................................................................................................................... 1 Description ............................................................................................................... 2 IDENTIFICATION OF PARTS.................................................................................... 3 INSTALLING THE GS3055-I ....................................................................................... 4 CONNECTING THE GS3055-I.................................................................................... 5 STATUS LEDS ........................................................................................................... 5 OPERATING PRINCIPLES ........................................................................................ 6 Simulated Land Line Mode ....................................................................................... 6 Inputs ....................................................................................................................... 6 ACTIVATING THE OUTPUTS .................................................................................... 7 Activating the Outputs ............................................................................................. 7 Contact ID ................................................................................................................ 7 Events Description ................................................................................................... 7 Event Codes ............................................................................................................ 7 "C-24 REMOTE" PROGRAMMING ............................................................................ 7 GS3055-I WIRING DIAGRAM .................................................................................... 8 INTRODUCTION The GS3055-I is a backup wireless communicator that sends alarm system information to a System III or System II receiver through a GSM/GPRS wireless network. FEATURES • • • • • • • • • • • Compatible with any listed panel that supports a 4 or 10-digit Contact ID Simulates land line Switches automatically to GSM network in the event land line trouble (line down) GSM Signal Indicator 4 programmable outputs Houses 12V - 1.2 Ah battery Case Tamper Output Land-line Overvoltage Protection Dual-Band GSM Radio 4 input lines GPRS/Internet communication with Sur-Gard System III / II TECHNICAL SPECIFICATIONS The input voltage to the GS3055-I can be drawn from the Control Panel or provided by an external UL Listed power supply rated for the application (external power-limited source). RATINGS Power Supply Ratings Input Voltage: ..................................................................................................... 9 - 14VDC (13.8VDC typical) Current: .................................... 120mA* (JP3 - OFF and internal battery required) or 500mA* (JP3 ON) * Plus any current drawn from the GS3055-I AUX+ terminal Battery: ................................................................................. sealed, rechargeable type, rated 12V/1.2Ah Recharging current: ............................................................................................................................. 50mA Current consumption Standby current: ................................................................................................................................ 120mA Alarm (Transmitting) current: ............................................................................................................. 450mA PGM outputs: ................................................................................................ 4, open collector, rated 50mA Operating frequency: ............................................................................................................ 850/1900MHz Antenna Gain: ....................................................................................................................................... 1.5dB Environmental specifications Operating temperature: .......................................................................................... 0°C-49°C (32°F-120°F) Humidity: ........................................................................................ 93%RH Maximum (Non-Condensing) Mechanical specifications Metal enclosure, painted; dimensions: .............................. 138mm x 224mm x 55mm / 5.4” x 8.8” x 2.2” Weight (without battery): ......................................................................................................... 900g / 3.2 oz Internal Event Buffer (communications): ........................................................... 256 Events (not viewable) Maximum loop resistance of line between the device connected in series on T1/R1: ................... 1Kohm This equipment GS3055-I is fixed and shall be installed by Service Persons only (Service Person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). It shall be installed and used within an environment that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only. This manual shall be used with the Installation Manual of the alarm control panel. All instructions specified within that manual must be observed. 1 Description This GS3055-I manages transmissions to a central station and can simulate the land line in the event of trouble (land line down) or even substitute the land line completely in areas where the GSM service is provided and where the land line is not available. The GS3055-I has the capability of communicating alarm signals via the GPRS data network. The capability enables a fast reliable path to central stations equipped with a Sur-Gard System III or System II receiver. By connecting a GS3055-I to a control panel's standard PSTN interface, telephone based Contact ID signals are decoded and seamlessly routed through the GPRS network to any of the compatible receiver options. The performance of the GS3055-I depends greatly on GSM Network coverage, therefore, it should not be mounted without first performing placement tests to determine the best location for reception (minimum one green LED is ON). Optional antenna kits are available. The GS3055-I requires enrollment with CONNECT 24 to operate. Dealer application forms and additional information on the CONNECT 24 Voice Response Unit (VRU) and web user-interface can be found at www.connect24.com or at the following telephone numbers: USA 1-888-251-7458 CANADA 1-888-955-5583 For UL Residential Fire and Burglary installations, the GS3055-I is listed as a primary (sole) communication means or as a back-up when used in conjunction with a POTS line (dialler). For UL Commercial Burglary installations, the GS3055-I is listed for supplementary (back-up) use in conjunction with a POTS line (dialler). For ULC Commercial Fire Monitoring installations the GS3055-I is listed as a passive communication system when used in conjunction with a POTS line (dialler). For ULC Commercial Burglary installations the GS3055-I is listed as a passive communication system with communication line security level P2 when used with conjunction with a POTS line (dialler). For ULC Residential Fire and Burglary installations the GS3055-I is listed as a primary (sole) communication means or as a back-up when used in conjunction with a POTS line (dialler). 2 IDENTIFICATION OF PARTS The numbers in square brackets [ ] in this manual refer to the main parts of the GS3055-I (see Fig.1 below) described in this section. 2 1 15 18 5 4 17 3 6 4 LOCK OPEN 6 1 5 JP3 9 1 - 2 3 4 TIP RNG T1 LE LI 5 R1 6 7 8 9 10 11 12 13 14 15 COM PGM1 PGM2 PGM3 PGM4 AUX+ TAMPER COM Z1 M O1 O2 O3 O4 +OC AS M 16 Z2 17 Z3 18 Z4 19 20 + 12V - L1 L2 L3 L4 +12V- 10 8 9 11 12 tie wrap 14 13 16 4 -I All circuits are classified for UL installations as Power Limited/Class II Power Limited except for the battery leads which are not power limited. Do not route any wiring over circuit boards. Maintain at least 1” (25.4mm) separation. A minimum 1/4” (6.4mm) separation must be maintained at all points between Power Limited wiring and all other Non-Power Limited wiring. Route wires as indicated in the diagram. N PARTS 1 Metal Casing GSM Antenna 2 3 GSM Antenna Nuts 4 Anchor Screw Holes (3mm) 5 Connector for GSM Antenna 6 SIM Card 7 LEDs 8 JP3 Current Limitation Jumper (refer to ratings section) 9 Programmable Jumper (Do not short these pins) 10 RS-232 Connector 11 Front plate Tamper Switch 12 Terminal Blocks 13 Battery Connector 14 Cable Entry 15 Earth Ground Wire 16 12V-1.2Ah Battery 17 GSM Module SIM Holder 18 3 Figure 1 - Parts INSTALLING THE GS3055-I CONNECT 24 Enrollment Information Only authorized dealers can enroll a GS3055-I with CONNECT 24. Dealer application forms and additional information on the CONNECT 24 Voice Response Unit can be found at the CONNECT 24 web site www .connect24.com www.connect24.com .connect24.com. Please contact CONNECT 24 at the number below for assistance: USA 1-888-251-7458 CANADA 1-888-955-5583 NOTE: Steps 1 and 2 should be completed before powering the GS3055-I unit. STEP 1 - Activate Your SIM Card Your SIM card must be activated with Connect 24 prior to use. Please call the Voice Response Unit (VRU) at least 24 hours prior to installation. STEP 2 - Initialize the GS3055-I with Connect 24 Call the VRU at the toll-free number. Follow the voice prompts and enter in your profile number, installer ID number, installer PIN number and central station number. Ensure all information is available before calling the VRU. All this information can be found in your VRU Enrollment Package. STEP 3 - Determine Best Signal Location 1. Remove the screw and the front cover [1]. 2. Fit the antenna [2] (ensure that the bolt [3] is fastened tightly). 3. Using the connector [5], connect the GSM Module [17]. Ensure the connector is secure. NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down. 4. Power up the GS3055-I and check signal strength. • Connect battery to the RED and BLK battery leads. • Connect DC Power source to +/- 12V terminals. • Allow unit to power up • The green LEDs will indicate the signal strength. The bottom green LED must be ON for the location to be acceptable. Please refer to the “Status LEDs” section for more information. 5. Power down the GS3055-I by removing the DC power source and battery leads. STEP 4 - Connect the GS3055-I 1. Using the cabinet, mark the 4 screw locations then drill the anchor screw holes. NOTE: Check for cable conduits and water pipes before drilling. 2. Using anchor screws (not included), mount the cabinet to the wall. 3. Run the cables, then pull them through the cable entry [14] or the knockouts provided. 4. Complete the connections on the terminal board [12]. Ensure power and Telco circuit connections are made only after the cabinet has been secured to the building or structure and has been connected to the protective earth ground. Descriptions of the terminals can be found in the “Connecting the GS3055-I” section. 5. Using the 4 screws, reattach the front cover [1] securely to the cabinet. NOTE: Please refer to Figure 2 at the end of this manual for wiring diagram. 4 CONNECTING THE GS3055-I (1) Earth Ground This terminal must be connected to the Mains Earth, in order to comply with the Telecommunications Network Safety Standards (Overvoltage Protection Requirements). TIP (2) / RNG (3) External telephone line These terminals must be connected directly to the incoming telephone line . T1 (4) / R1 (5) Internal telephone line These terminals must be connected to the TIP and RING of the control panel. COM(6,14) Common This terminal is connected internally to Power Ground. PGM1 (7), PGM2 (8), PGM3 (9), PGM4 (10) Programmable open-collector outputs These outputs can be activated by programmed events, refer to “Activating the Outputs” for details. The maximum current sink of each output must not exceed 50mA. AUX+ (11) Auxiliary 12V Output +12V Output, 200mA PTC Protected. NOTE: Current drawn from this terminal is directly from the power supply mining the total draw on the supply.. This needs to be added to the GS3055-I cur currrent when deter determining host panel or power supply supply.. Jumper JP3 does not limit the cur currrent available on this output. Tamper (12-13) 11 11]. They will be closed when the These terminals are connected in series to the Tamper microswitch [11 cabinet is properly closed, and will open when the front cover is removed. Z1-Z4 (15-16-17-18) Programmable Inputs These terminals can be set up to trigger events. Refer to “Inputs” section for details. 12V (19), COM (20) Device Power Supply These terminals must be connected to a rated power supply. 13 Once the connections are completed, connect the Red and Black wires [13 13] to a 12V, 1.2Ah battery. Jumper JP3 JP3 ON - Full power comes from the host panel or external power supply. Supply must be capable of up to 700mA, the GS3055-I battery must NOT be connected. JP3 OFF - Current Limiting Mode. Host panel or external supply provide standby current. Supply must be capable of 120mA plus any current drawn from AUX+ terminal. GS3055-I battery must be installed for proper operation. The Power Supply must have a minimum voltage of 13.5 to ensure sufficient battery charge. NOTE: When disposing of batteries, follow the instructions and and precautions printed on the batteries, and contact your municipal offices for information on the disposal of used batteries. STATUS LEDS The GS3055-I interface has 4 status LEDs. NOTE: The top two LEDs will blink during the Initializing and Programming phases. The following section describes the Control panel status LEDs. RED — This LED is Normally OFF, it will blink in the event of trouble. This LED will switch ON within 3 17 minutes in the event of GSM Module [17 17] trouble, or when the GSM Network is unavailable (NO SERVICE). If this LED blinks, the following list will indicate the specific trouble based on the number of blinks, by priority. On power-up, the GS3055-I will check for trouble conditions to be restored in the order listed below. It will indicate the status of the highest priority, unrestored trouble condition with the corresponding number of flashes of the RED LED. Once the highest priority trouble condition has been cleared, the next highest priority trouble condition will be displayed. 1 flash - Battery Trouble (Battery absent or battery with low voltage output) 2 flashes - Radio/SIM Failure (Battery absent or check SIM Card connection) 3 flashes - GSM Network Problem (SIM not active, poor signal strength, antenna not connected) 4 flashes - Insufficient Signal Strength (Poor location) 5 flashes - Connect 24 Configuration SMS Failure (Improper VRU programming) 6 flashes - Receiver Not Available (Improper VRU programming, receiver absent) 7 flashes - Power Supply Trouble (DC power supply absent) Of Offf - No Troubles 5 YELLOW — This LED will switch ON when the interface switches to the GSM Network (due to land line trouble). This LED can also blink quickly once (GPRS TX) or twice (GPRS RX). GREEN (Top) — When this LED is ON ON, the reception is optimal. This LED will switch ON only when the other GREEN LED is ON. GREEN (Bottom) — If this LED is OFF and the RED LED is ON, the GSM Network service is unavailable (NO SERVICE) SERVICE). This LED will Blink when the GSM Network reception is bad. If this LED is ON ON, the GS3055-I will be able to communicate to the GSM network. OPERATING PRINCIPLES Simulated Land Line Mode The simulated land line provides the alarm control panel (with dialler interface) with a backup line in the TIP/RNG event of PSTN line trouble. If the voltage on the land line terminals (TIP/RNG TIP/RNG) drops below 4V for a period of between 10 to 45 seconds (depending on the device connected to the T1/R1 terminals), the GS3055-I will switch the connected telephone device to the GSM Network for a full 15 minute interval, at the end of this interval, it will check the land line: • if the land line has been restored restored, it will switch the connected device back to the land line; • if the land line is still down down, it will continue to simulate the land line until it is restored. The GS3055-I will not switch during ongoing calls NOTE: When the land line is down, the GS3055-I will provide a dial tone to any device connected to T1 and R1, including any telephones on the premises. However, the premise phones will not be able to dial out over the GS3055-I. Sequence • When alarm is triggered, the Alarm Panel goes off-hook • The GS3055-I will assert dial tone • Control Panel dials the number of the central station. Ensure the alarm panel inserts a minimum 1second pause, or has dial tone search enabled before dialing the number • The GS3055-I detects the DTMF dialing and stops dial tone NOTE: The GS3055-I is unable to decode pulse dialing. • The GS3055-I will send the required Contact ID dual tone handshake to the panel • After receiving the handshake, panel transmits alarm message in Contact ID format • The GS3055-I decodes and transforms Contact ID digits into the IP packet and sends it to the Central Station Receiver over the GPRS network • The receiver acknowledges the alarm and sends command to the GS3055-I to generate the corresponding 1400Hz kiss-off signal for 800ms minimum • After the GS3055-I generates kiss-off, the panel goes on-hook if no more alarms need to be sent, or it can send the next alarm Inputs The GS3055-I has 4 inputs that can be used to trigger specific communications. These events will transmit using Contact ID format with Input 1-4 reporting as [991] to [994] respectively. Default settings below: INPUT 1- FIRE INPUT 3 - BURGLARY INPUT 2 - PANIC ALARM INPUT 4 - SYSTEM TROUBLE These inputs are normally open and will activate when a short condition is detected between the terminal and the COM. Refer to the GS3055-I Wiring Diagram (Figure 2) at the back of this manual. NOTE: When the GS3055-I is configured in Land Line Mode, these inputs should be restricted to monitoring of trouble conditions. NOTE: These inputs communicate using Contact ID format. NOTE: For UL/ULC installations, connections between alarm panel outputs and GS3055-I inputs shall be run in mechanical protective conduits. To reduce interference with the antenna, it is recommended that the metal conduit is not connected to the knock-outs on the top of the cabinet. 6 ACTIVATING THE OUTPUTS The GS3055-I has 4 programmable outputs to activate in response to the associated events. Refer to the GS3055-I Wiring Diagram (Figure 2) at the back of this manual. Activating the Outputs The GS3055-I has 4 open collector outputs capable of a maximum of 50mA. Internal events on the GS3055-I can trigger the outputs to turn on an LED or activate an input on the host panel. The default settings are as follows: OUTPUT 1 - Land Line T Trrouble Output is normally high and will switch to ground when the telephone line is down. OUTPUT 2 - GSM Model or Network T Trrouble Output is normally high and will switch to ground when the GS3055-I can’t connect or communicate to the GSM network. OUTPUT 3 - Power Supply or Batter yT Battery Trrouble Output is normally high and will switch to ground when there is a problem with the power source. OUTPUT 4 - General Module T Trrouble Output is normally low and will switch to high when any of the previous troubles occur and/or a Failure to Communicate (FTC) trouble is detected. NOTE: Once an output has been activated automatically, it will not restore its state until all the causes of activation are cleared. Contact ID Events Description Event Codes Input 1 activation: ............................................................................................... E110 FIRE ZONE 001 991 Input 1 Restoral: ................................................................................................. R110 FIRE ZONE 001 991 Input 2 activation: ................................................................................... E120 Panic Alarm ZONE 002 992 Input 2 Restoral: ..................................................................................... R120 Panic Alarm ZONE 002 992 Input 3 activation: ........................................................................................ E130 Burglary ZONE 003 993 Input 3 Restoral: .......................................................................................... R130 Burglary ZONE 003 993 Input 4 activation: ............................................................................ E300 System Trouble ZONE 004 994 Input 4 Restoral: .............................................................................. R300 System Trouble ZONE 004 994 PSTN Line down: .............................................................................................. E351 TELCO 1 FAULT 000 PSTN Line Restoral: .......................................................................................... R351 TELCO 1 FAULT 000 12V INPUT LOSS: .................................................................................... E337 EXP. MOD. DC LOSS 000 12V INPUT RESTORAL: .......................................................................... R337 EXP. MOD. DC LOSS 000 LOW BATTERY ALERT: ........................................................................... E338 EXP. MOD. LOW BAT 000 LOW BATTERY RESTORAL: .................................................................... R338 EXP. MOD. LOW BAT 000 PERIODIC REPORT: ................................................................................. E603 Periodic RF Xmission 000 GSM UNIT ACTIVATION: ....................................................................... R552 Radio Xmitter Disabled 000 GSM INTERNAL BUFFER FULL: ...................................................... E624 EVENT LOG OVERFLOW 000 FTC RESTORAL: ......................................................................... R354 FAILURE TO COMMUNICATE 000 "C-24 REMOTE" PROGRAMMING The inputs, outputs and other features can be remotely programmed through Connect-24 (C-24) for fast and convenient installation through the world wide web. NOTE: This programming option has not been investigated by UL. 7 GROUND CONNECTION RJ-45 Earth-ground Ground wire from building electrical installation 2 LE 3 R I N G WARNING! optional use of PGM output (See Programming) Connect relay contacts to a zone input on the alarm control panel for GS3055-I troubles supervision (24h type zone) RM-1 Relay 1K5 6 O1 7 O2 8 O3 9 O4+OC 10 11 12 AS13 14 15 L116L217L3 18 L4 1912V20 COM6 PGM1 PGM411 AUX+ TAMPER Z1 15Z216Z317 Z4 7 PGM2 8 PGM3 9 10 18 + 1912V 2012 13 COM 14 HIGH VOLTAGE. DISCONNECT AC POWER & TELEPHONE LINES PRIOR TO SERVICING 8 Fig. 2 - Wiring Diagram Tamper Output WARNING: Incorrect connections may result in PTC failure or improper operation. Inspect wiring and ensure connections are correct before applying power All circuits are classified for UL installations as Power Limited/Class II Power Limited except for the battery leads which are not power limited. Do not route any wiring over circuit boards. Maintain at least 1” (25.4mm) separation. A minimum 1/4” (6.4mm) separation must be maintained at all points between Power Limited wiring and all other Non-Power Limited wiring. Route wires as indicated in the diagram. Inputs to be connected to dry contact outputs from alarm control panel Sealed Rechargeable 12V / 1.2Ah BATTERY Battery not required if JP3 is ON Typical battery charge: 30-50 mA Recommended Model: DSC BD 1.2-12 External 9-14VDC/ *700mA (max) Power Supply *Refer to Jumper 3 section for current rating } Alarm Control Panel with Dialler Interface (Supports Contact ID format) T I P 4LI 5 3 4T1 5R1 1 TIP 2 RNG 1 Telephone Line Connection (Use No. 26 AWG wires for the connection to PSTN) Tighten nut to break paint & make good connection to the cabinet. Nut Lock washer Nut Lock washer Star washer Cabinet Bolt GS3055-I This Connection is necessary APPENDIX - WIRING DIAGRAMS BROWN (T) GRAY (R) GREEN (T) 9 RING TIP RED (R) RING TIP TIP RNG T1 R1 TIP GS3055-I RING 6 7 COM 1 (used to power the GS3055-I Radio) Auxiliary Power Supply (Optional) 4 AUX+ TAMPER COM Z1 Z2 Z3 Z4 + 12V - 9 10 11 12 13 14 15 16 17 18 19 20 PGM 2 3 8 Supervision Relay See Note 2 3. Output 4 on the GS3055-I must be set as “Active High”. When the GS3055-I is powered by the control panel the relay is not required since a loss of voltage at the power input terminals on the GS3055-I will generate a trouble signal transmission to the monitoring station. 2. A supervision relay, DSC model RM-2 can be used, as indicated in Fig. 4 in order to provide supervision of the control panel (for total power loss) when the GS3055-I is powered by a Separate Power Supply. Fig. 4 - Optional Power Supply Supervision Wiring Diagram GS3055-I C 5 DSC RM-2 Relay NO 4 - NC 3 Control Panel EOL Resistor See Note 3 + GND GND 2 Incoming Handset Phone line + +12VDC +12VDC Fig. 3 - Telephone Connection 1 RJ-31X CONTROL PANEL - Aux Power CONTROL PANEL ZONE TERMINALS (See Note 1) 1. Program the Control Panel’s input Zone/Point as 24h “Supervisory” type with the keypad only annunciation when activated. NOTES: GS3055-I WIRING DIAGRAMS RING TIP FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart "B" of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient the receiving antenna • Relocate the alarm control with respect to the receiver • Move the alarm control away from the receiver • Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/ television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: "How to Identify and Resolve Radio/Television Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4. IMPORTANT INFORMATION This equipment complies with Part 68 of the FCC Rules. On the side of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this number must be provided to the Telephone Company. GS3055-I Product Identifier US: F53AL00BGS3055 REN: 0.0B USOC Jack: RJ-31X Telephone Connection Requirements A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details. Ringer Equivalence Number (REN) The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local Telephone Company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format. US: AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. Incidence of Harm If this equipment GS3055-I causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the Telephone Company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. Changes in Telephone Company Equipment or Facilities The Telephone Company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the Telephone Company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. Equipment Maintenance Facility If trouble is experienced with this equipment for repair or warranty information, please contact the facility indicated below. If the equipment is causing harm to the telephone network, the Telephone Company may request that you disconnect the equipment until the problem is solved. This equipment is of a type that is not intended to be repaired by the end user. DSC c/o APL Logistics, 757 Douglas Hill Rd., Lithia Springs, GA 30122 Additional Information Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. Alarm dialling equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialling equipment must be connected to a properly installed RJ-31X jack that is electrically in series with and ahead of all other equipment attached to the same telephone line. Proper installation is depicted in the figure below. If you have any questions concerning these instructions, you should consult your telephone company or a qualified installer about installing the RJ-31X jack and alarm dialling equipment for you. Customer Premises Equipment and Wiring Network Service Provider's Facilities Computer RJ-31X Jack Alarm Dialing Equipment Unused RJ-11 Jack Telephone Line Telephone Network Demarcation Point Fax Machine Telephone Answering System Unused RJ-11 Jack Telephone Industry Canada Compliance Statement This Equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that that Industry Canada approved the equipment. The Ringer Equivalence Number (REN) for this terminal equipment is 0.0. The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all devices does not exceed 5. Cet équipement est conforme aux spécifications techniques applicables aux équipements terminaux d'Industrie Canada. Ceci est confirmé par le numéro d'enregistrement. L'abréviation IC précédant le numéro d'enregistrement signifie que l'enregistrement a été effectué sur la base de la Déclaration de conformité indiquant que le produit est conforme aux spécifications techniques d'Industrie Canada. Ceci n'implique pas que le produit ait été approuvé par Industrie Canada. Le nombre équivalent de sonneries (REN) de cet appareil terminal est 0.0. Le REN attribué à chaque équipement terminal fournit une indication sur le nombre maximum de terminaux pouvant être connectés sur une interface téléphonique. La terminaison sur une interface peut constituer en n'importe quelle combinaison d'appareils, à la condition seulement que la somme des Nombres équivalents de sonneries de tous les appareils ne soit pas supérieure à 5. This Class B digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la Classe B respecte toutes les exigences de règlement sur le matériel brouilleur du Canada. The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This manual is applicable to the following GS3055-I Cellular Alarm Communicator Models: GS3055-1 FCC ID: F5306GS30551 and IC: 160A-GS30551 GS3055-2 FCC ID: F5306GS30552 and IC: 160A-GS30552 WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20cm or more must be maintained between the antenna of this device and persons during device operation. Printed in Canada 2 9 0 0 7 3 1 4 R0 0 4
advertisement
Key Features
- Backup wireless communicator
- GSM/GPRS wireless network
- Compatible with listed panels
- Simulates land line
- Switches to GSM network in case of landline trouble
- 4 programmable outputs
- Houses 12V - 1.2 Ah battery
Related manuals
Frequently Answers and Questions
What is the purpose of the DSC GS3055-IG?
The GS3055-IG is a GSM-GPRS interface module that provides backup wireless communication for alarm systems. It sends alarm system information to a System III or System II receiver through a GSM/GPRS wireless network.
What are the key features of the GS3055-IG?
It simulates a land line, switches automatically to GSM in case of landline trouble, has 4 programmable outputs, houses a rechargeable battery, includes tamper protection, provides land-line overvoltage protection, utilizes a dual-band GSM radio, and has 4 input lines for interfacing with various sensors or devices.
What power source does it typically use?
The GS3055-IG's power can be drawn from the connected control panel or supplied by an external UL-listed power supply rated for the application.
What is the maximum loop resistance allowed for the line between devices connected on T1/R1?
The maximum allowed loop resistance is 1 kohm.
What is the environmental rating of the GS3055-IG?
It operates within a temperature range of 0°C-49°C (32°F-120°F) and a humidity of 93%RH maximum (non-condensing).
Download
PDF
advertisement
Table of contents
- 3 INTRODUCTION
- 3 FEATURES
- 3 Technical Specifications
- 3 Ratings
- 4 Description
- 5 IDENTIFICATION OF PARTS
- 6 INSTALLING THE GS3055-I
- 7 CONNECTING THE GS3055-I
- 7 STATUS LEDS
- 8 OPERATING PRINCIPLES
- 8 Simulated Land Line Mode
- 8 Inputs
- 9 ACTIVATING THE OUTPUTS
- 9 Activating the Outputs
- 9 Contact ID
- 9 Events Description
- 9 Event Codes
- 9 "C-24 REMOTE" PROGRAMMING
- 10 GS3055-I WIRING DIAGRAM