2.3 Troubleshooting the Optional Polar
®
Telemetry Heart Rate Chest Strap
Heart Rate Reading Is Initially Detected then Lost or Abnormally Elevated
Malfunction
Heart rate reading is initially detected and functioning normally but then is lost.
Probable Cause Corrective Action
Use of personal electronic devces, such as cell phones and portable MP3 players, causes external noise interference.
Equipement is in close proximity to other sources of noise such as audio/ video equipment, fans, two way radios, and high voltage/highcurrent power lines.
Remove the source of noise or reposition the exercise equipment.
Heart rate readings are abnormally elevated.
Television sets and/or antennas generate electromagnetic interference.
Cell phones generate electromagnetic interference.
Computers generate electromagnetic interference.
Cars generate electromagnetic interference.
High voltage power lines generate electromagnetic interference.
Move the treadmill a few inches away from the probable cause, or move the probable cause a few inches away from the treadmill, until the heart rate readings are accurate.
Motor driven exercise equipment generates electromagnetic interference.
Another heart rate transmitter within three feet (one meter) generates electromagnetic interference.
10
Troubleshooting the Optional Polar
®
Telemetry Heart Rate Chest Strap
(
CONTINUED
)
Heart Rate Reading Is Erratic Or Absent Entirely
Malfunction
Heart rate reading is erratic or absent entirely.
Probable Cause
Belt transmitter electrodes are not wet enough to pick up accurate heart rate readings.
Corrective Action
Wet the belt transmitter electrodes (see Section 3.2).
Belt transmitter electrodes are not laying flat against the skin.
Ensure the belt transmitter electrodes are laying flat against the skin (see Section 3.2).
Belt transmitter needs cleaning.
Wash the belt transmitter with mild soap and water.
Belt transmitter is not within 3 feet (1 meter) of the heart rate receiver.
Make sure the chest strap transmitter is within 3 feet (1 meter) of the heart rate receiver.
Polar telemetry heart rate chest strap battery is depleted.
Contact Life Fitness Customer
Support Services for instructions on how to have the Polar telemetry heart rate chest strap replaced.
Polar telemetry heart rate chest strap did not lock in with the heart rate receiver.
Make sure the Polar telemetry heart rate chest strap is installed and move closer to the heart rate receiver. Wait up to 10 seconds for the heart rate to display on the console.
Notes:
1. Ensure proper adherence of the Polar telemetry heart rate chest strap to user’s chest.
2. Ensure proper conductivity between the electrodes and user’s chest.
3. If needed, use the Polar watch to verify chest strap’s operation.
11