Special Remarks. Sanyo KHS1251, KHS1852, KHS0951
Add to My manuals28 Pages
Sanyo KHS0951 is a split system air conditioner that offers cooling, heating, and drying functions. It features a microprocessor-controlled operation for automatic and efficient performance. With its simple one-touch wireless remote control, you can easily adjust settings, set timers, and control airflow direction.
advertisement
Special Remarks
``DRY'' ( ) Operation
How it works?
•
•
•
Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between
LOW (for 20 seconds) and VERY LOW (for 10 seconds).
“DRY” operation is not possible if the indoor temperature is 59
°
F or less.
Heating ( ) Operation
Heating performance
Defrosting
STANDBY lamp
STANDBY lamp
OPERATION STANDBY TIMER
•
•
•
•
•
Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it.
When the outdoor temperature is low, frost or ice may form on the heat exchanger coil, reducing heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan on the indoor unit stops and the STANDBY lamp remains lit until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms).
For several minutes after the start of heating operation, the indoor fan will not start running until the indoor heat exchanger coil has warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period, the
STANDBY lamp remains lit.
The STANDBY lamp also remains lit during defrosting or when the compressor has been turned off by the thermostat when the system is in the heating mode.
Upon completion of defrosting and when the compressor is turned on again, for heating operation, the STANDBY lamp will go off automatically.
oi330000
Power failure during operation
• In the event of power failure, the unit will stop. When the power is resumed, the unit will restart automatically after five minutes.
Clicking Sound
Clicking sound is heard from the air conditioner
• In heating or cooling operation, any plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear.
Remote Control Unit
• The remote control unit sends the setting condition to the air conditioner regularly at five minute intervals.
18
OI-351-18EG
Setting the Timer
3
1
1.
How to set the present time
4
2
(Example) To set to 9:10 pm.
Operation
1. Press the Program button ( three times.
)
2.
•
Press the HH button until PM 9 is displayed.
•
Press the MM button until 10 is displayed.
Indication
The time indication alone blinks.
The display will automatically stop blinking except for the “:” symbol after 10 sec.
2.
How to set the OFF time
(Example) To stop the air conditioner at 11:30 pm.
1. Press the Program button ( once.
)
2.
•
Press the HH button until PM 11 is displayed.
•
Press the MM button until 30 is displayed.
The timer indication blinks and present OFF time is shown.
The display will change automatically back to show the present time after 10 sec.
3. Press the ON/OFF button to start the air conditioner.
The present time is displayed.
4. Press the TIMER SELECT button to set OFF time.
The present time and displayed.
are
19
OI-351-19EG
Setting the Timer (continued)
3.
How to set the ON time
(Example) To start operation at 7:10 am.
Operation Indication
1. Press the Program button ( twice.
)
2.
•
Press the HH button until AM 7 is displayed.
•
Press the MM button until 10 is displayed.
The timer indication blinks and present ON time is shown.
The display will change automatically back to show the present time after 10 sec.
3. Press the ON/OFF button to start the air conditioner.
The present time is displayed.
4. Press the TIMER SELECT button to set ON time.
The present time and are displayed.
4.
How to set a program for daily ON/OFF operation
Present time
(Example) To start operation at 7:10 am. and stop the air conditioner at
11:30 pm.
7:10 am
ON
11:30 pm
OFF
20
OFF time
1. Set the timer ON/OFF times as shown in 2-1, 2 and 3-1, 2.
2. Press the ON/OFF button to start the air conditioner.
ON time
3. Press the TIMER SELECT button to set the ON/OFF combination timer.
The present time PM 9:10 and
are displayed.
Programed daily
ON/OFF
NOTE When the Daily ON/OFF program is set to start the air conditioner before the ON time setting, the indications appear on the display.
On the other hand, when the Daily ON/OFF program is set to start the air conditioner after the ON time setting, the indications appear on the display. Thus, these indications show the timer program which will operate next.
NOTE You can check the timer ON/OFF times after you have set them by pressing the PROGRAM button.
OI-351-20EG
advertisement
Related manuals
advertisement
Table of contents
- 2 Features
- 3 Product Information
- 3 Alert Symbols
- 4 Installation Location
- 4 Electrical Requirements
- 4 Safety Instructions
- 5 Names of Parts
- 10 Using the Remote Control Unit
- 12 Operation with the Remote Control Unit
- 12 1. Automatic Operation
- 14 2. Manual Operation
- 15 3. Adjusting the Fan Speed
- 16 4. Night Setback Mode
- 18 Special Remarks
- 21 Setting the 1-Hour OFF Timer
- 22 Adjusting the Airflow Direction
- 23 Operation without the Remote Control Unit
- 23 Care and Cleaning
- 26 Tips for Energy Saving
- 27 Troubleshooting
- 27 Operating Range