Hose Hook-up & Inlets
Before operating your central vacuum…
Please verify that it is properly connected to the piping system, and to a grounded electrical outlet, and that the low voltage wires are connected to the unit (see pages 8 to 16). Then read the complete owner’s manual and proceed with a quick verifi cation of your unit’s installation:
• Check fi lters to be sure they are properly installed.
• Check rubber seals in each vacuum inlet.
• Plug the hose alternatively into each vacuum inlet, to ensure that each one works properly.
• While the hose is still plugged into one inlet and the system is operational, check other inlets for leaks.
To start your central vacuum, simply insert the hose in the vacuum inlet of your choice. Please ensure that the tab on the hose end is properly lined up with the slot in the inlet opening (fi gure 16). If your hose handle has an integrated on/off switch, simply slide the switch to the “on” position.
Do not try to open another inlet while your system is in operation, as it may damage the inlet’s rubber seal.
18 fi gure 16
Operating Instructions
Speed Variation Hose
(DL Series Only)
Exclusive to Cyclo Vac, the Speed Variation hose allows the selection of 4 power levels by the simple slide of a switch on the hose handle. The light emitting diodes on the “Speed Variation” hose indicate the power level chosen. Flashing diodes inform you that the time has come to empty the receptacle or clean the fi lters. Refer to the maintenance suggestions module or the integrated system monitor on the unit itself (see pages 23 and 24).
WARNING
The use of an “SV” hose with a vacuum unit
other than that of the Cyclo Vac DL “SV” series will cause irreversible damage to your hose which would not be covered by the warranty.
Progressive Start and Delayed Stop
(DL Series Only)
Each DL model is equipped with a special module allowing for a smooth and gradual start-up of the vacuum system, to prolong motor durability. It will also come to a complete stop within a few seconds after it has been turned off, to allow for the complete evacuation of dust from the hose.
Operating Instructions 19
20
Maintenance Suggestions Module
(DL Series Only)
Cyclo Alert
Your unit is equipped with an electronic timing board that will suggest, by the color of the blinking LED, the type of maintenance that should be done. These signals are only suggestions and do not indicate a problem with your unit.
Your central vacuum will work normally despite the fl ashing LEDs. When you initially connect your unit, the LEDs will be green and steady. When the LEDs on the hose handle blink, no matter the color, refer to the unit itself for status. It may be time to change the fi lters, empty the dirt receptacle and/or have the motor(s) inspected.
#)
2#5)4
%!
S RES
Reset
LED
Low voltage
Blinking green
• We suggest you clean the fi lters and empty the dirt receptacle.
Blinking amber
• We suggest that you change the fi lters.
Blinking red
• We strongly suggest you change the fi lters (if it was not done previsously) and have an authorized service center inspect the motor(s). A tune-up may be required.
Blinking green / amber / red
• It is time to bring your unit to an authorized service center. Your unit has accumulated a considerable number of hours, and may require maintenance. A complete inspection is therefore strongly recommended.
To reset the electronic timing board
• Hold the reset switch for 10 seconds.
Operating Instructions
Integrated System Monitor
(DL300 only)
Your central vacuum unit is equipped with an electronic timing device which will recommend by a series of light emitting diodes (LEDs) proper maintenance of your vacuum system. These signals are only suggestions and will do not indicate a problem with your vacuum system. They will not stop or hinder the use of the vacuum.
When you initially plug in your vacuum, the LEDs will signal “OK”. Then, according to the number of hours the system has been use the LEDs will suggest the proper preventive maintenance.
OK, system is operational
Empty receptacle and clean fi lters
Change the carbon dust fi lter
Have the vacuum power unit inspected by an authorized service center
RESET – press to stop fl ashing diodes and reset the electronic timing device.
Remote System Monitor
(Optional — DL300 only)
Installed in a strategic location in your home, it provides the same information as the Integrated System Monitor. Once you have reset the electronic timing device
(on the unit itself), the remote monitor will once again signal “OK”.
Operating Instructions 21
22
Cyclo Vac Attachments
Oval Dusting Brush
Use just about anywhere: on lamps & lamp shades, blinds, shelves, decorative trims
Upholstery Brush
With removable bristles, use to clean all upholstered furniture such as sofas, chairs, and mattresses.
Crevice Tool
Use in narrow spaces, nooks and crannies, such as heating ducts, between sofa cushions, and between window panes.
Floor Brush
For use on all types of fl ooring: hardwood, ceramic or even small carpets.
Carpet Brush (optional)
Specially designed for small carpets and area rugs, it cleans down deep.
Operating Instructions
Cyclo Vac Attachments
Hose Holder
In addition to conveniently holding your hose, it’s specially designed to allow the storage of your fl oor brush on the telescopic wand, without crushing the brush bristles.
Telescopic Wand
It’s easily adjusted to the desired height. Simply depress the button, slide the wand to the desired length, and release the button for it to lock into position. Convenient button-lock mechanisms prevent the wand from slipping off the hose handle.
Attachment Holder
Made of durable vinyl, it conveniently holds all your accessories. Hang it on your hose holder, to keep all accessories at hand.
push button here
Operating Instructions 23