Section 1: General Information. OWON SDS 8202, SDS 7102, SDS 8102, SDS 6062
Add to My manuals46 Pages
The SDS 6062, SDS 7102, SDS 8102, SDS 8202 Digital Storage Oscilloscopes are designed for use in a variety of applications, including education, research, and industrial settings. These oscilloscopes offer a wide range of features and capabilities, including high bandwidth, real-time sampling rates, and a variety of measurement functions.
advertisement
Section 1: General Information
Section 1: General Information
1.1 Introduction
This service manual contains information on adjusting and servicing the SDS Series Oscilloscope.
Chapter General Information simply introduces the specifications of the oscilloscope.
Chapter Installation introduces the theory of installing.
Chapter Test and Calibration simply introduces some theory and method of tests.
Chapter Debugging and Calibration supplies some modules for adjust and some methods.
Chapter Maintenance mainly supplies some parts to customers for service
Chapter Replaceable Parts mainly introduces theories and methods of servicing.
1.2 Accessories Supplied
Standard Accessories: z 2 Passive probe: 1.2 m, 1:1 (10:1) z CD: x 1 (PC link application software) z Power cord: 1pcs, up to the standards of the country in which it is used. z USB cable z User Manual: 1pcs
Options: z Battery
1.3 Technical Specifications
Unless otherwise specified, the technical specifications applied are applicable to the probe with the attenuation switch setting 10X and the SDS series digital oscilloscope. Only if the oscilloscope fulfill the following two conditions at first, can these specification standards be reached.
This instrument should run for more than 30 minutes continuously under the specified operating temperature. open the system function menu and execute the “Auto-calibration” procedure
(see “4.4 Auto-calibration” on P17).
All specification standards can be fulfilled, except one(s) marked with the word
“Typical”.
1
Section 1: General Information
Table 1: Specifications (cont.)
Performance Characteristics Instruction
Bandwidth
Acquisition
Input
Horizontal
System
Channel
Mode
Sample rate
(real time)
SDS6062 60MHz
SDS7102 100MHz
SDS8102 100MHz
SDS8202 200MHz
2 + 1 (External)
Normal, Peak detect, Averaging
SDS6062
500MS/s
(250MS/s for dual channels)
SDS7102
SDS8102
SDS8202
1GS/s
(500MS/s for dual channels)
2GS/s
(1GS/s for dual channels)
2GS/s
(1GS/s for dual channels)
DC, AC , Ground
1MΩ±2%, in parallel with 10pF±5pF
Input coupling
Input impedance
Probe attenuation factor
1X, 10X, 100X, 1000X
Max. input voltage 400V (PK-PK) (DC + AC PK-PK)
Bandwidth limit
20MHz, full bandwidth
Channel –channel isolation
50Hz: 100 : 1
10MHz: 40 : 1
Time delay between channel(typical)
150ps
Sampling rate range
SDS6062
SDS7102
SDS8102
SDS8202
0.5S/s~500MS/s single channel*
0.5S/s~250MS/s dual channel
0.5S/s~1GS/s single channel*
0.5S/s~500MS/s dual channel
0.5S/s~2GS/s single channel*
0.5S/s~1GS/s dual channel
0.5S/s~2GS/s single channel*
0.5S/s~1GS/s dual channel
Record length
Scanning speed
(S/div)
2
10M points on each channel
SDS6062
SDS7102
5ns/div~100s/div, step by 1~2~5
2ns/div~100s/div, step by 1~2~5
Section 1: General Information
Table 1: Specifications (cont.)
Performance Characteristics Instruction
SDS8102
SDS8202
2ns/div~100s/div, step by 1~2~5
1ns/div~100s/div, step by 1~2~5
Sampling rate / relay time accuracy
±100ppm
Single:
Interval( T ) accuracy
(DC~100MHz)
±(1 interval time+100ppm×reading+0.6ns);
Average>16:
A/D converter
±(1 interval time +100ppm×reading+0.4ns)
8 bits resolution (2 Channels simultaneously)
Sensitivity 2mV/div~10V/div
Vertical system
Displacement
Analog bandwidth
Single bandwidth
Low Frequency
Rise time
SDS6062 ±10 div
SDS7102
± 1V(2mV~100mV);
SDS8102 ± 10V(200mV~1V);
SDS8202 ± 100V(2V~10V)
60MHz, 100MHz, 200MHz, 300MHz
Full bandwidth
≥5Hz (at input, AC coupling, -3dB)
SDS6062 ≤5.8ns (at input, Typical)
SDS7102 ≤3.5ns (at input, Typical)
SDS8102 ≤3.5ns (at input, Typical)
SDS8202 ≤1.7ns (at input, Typical)
±3%
Measurement
DC accuracy
DC accuracy
(average)
Cursor
Average﹥16: ±(3% rdg + 0.05 div) for V
△ △
3
Section 1: General Information
Table 1: Specifications (cont.)
Performance Characteristics Instruction
Automatic
Vpp, Vmax, Vmin, Vtop, Vbase, Vamp,
Vavg, Vrms, Overshoot, Preshoot, Freq,
Period, Rise Time, Fall Time, Delay A→B ,
DelayA→B , +Width, -Width, +Duty, -Duty
Waveform Math
Waveform storage
Lissajous figure
Bandw idth
Phase differe nce
Frequency ( typical)
+ , -, *, / ,FFT
15 waveforms
Full bandwidth
±3 degrees
1KHz square wave
Communication port
USB2.0, USB for file storage, VGA port or RS-232
﹡ Single channel is when only one input channel is working.
4
Section 1: General Information
Table 1: Specifications (cont.)
Trigger:
Performance Characteristics
Internal
Trigger level range EXT
EXT/5
Trigger level
Accuracy (typical)
Internal
EXT
EXT/5
Trigger displacement
Trigger Holdoff range
50% level setting
(typical)
100ns~10s
Input signal frequency ≥50Hz
Instruction
±6 div from the screen center
±600mV
±3V
±0.3div
±(40mV + 6% of Set Value)
±(200mV +6% of Set Value)
According to Record length and time base
Edge trigger
Pulse trigger slope Rising, Falling
Sensitivity 0.3div
Trigger condition
Positive pulse:>, <, = negative pulse:>, <, =
Pulse Width range 24ns~10s
Modulation
Support standard NTSC, PAL and
SECAM broadcast systems
Video Trigger
Line number range 1-525 (NTSC) and 1-625 (PAL/SECAM)
Slope Trigger
Alternate Trigger
Trigger condition
Time setting
Trigger on CH1
Trigger on CH2
Positive pulse:>, <, = negative pulse:>, <, =
24ns~10s
Edge, Pulse, Video, Slope
Edge, Pulse, Video, Slope
5
Section 1: General Information
1.4 General Technical Specifications
Table 2: General specifications
Display
Display Type 8” Colored LCD (Liquid Crystal Display)
Display Resolution 800 (Horizontal) × 600 (Vertical) Pixels
Display Colors 65536 colors, TFT screen
Output of the Probe Compensator
Output Voltage
(Typical )
About 5V, with the Peak-to-Peak greater than 1MΩ of load.
Frequency (Typical ) Square wave of 1KHz voltage equal to or
Table 2: General Specifications (cont.)
Power
Mains Voltage 100~240 VAC RMS, 50/60Hz, CAT II
Power Consumption < 18W
Fuse 1A, T grade, 250V
Battery (optional)
Cell:558792 4000mAh/3.7V
Pack:2s2p 7.4V/8000mAh
Mechanical Specifications
Dimension 340mm× 155mm×70mm (L*H*W)
Weight About 1.82 kilogram
Interval Period of Adjustment:
One year is recommended for the calibration interval period.
6
Section 1: General Information
1.5 Declaration of Conformity
SDS Series Smart Digital Storage Oscilloscopes
Manufacturer: Fujian Lilliput Optoelectronics Technology Co., Ltd.
Statement of Conformity
Base on the result using appropriate standards, the product is in conformity with
Electromagnetic Compatibility Directive 2004/108/EC Annex Ⅱ
Low Voltage Directive: 2006/95/EC
Sample tests
Standards used:
EN61010-1:2001
Safety Requirements for Electrical Equipment for Measurement, Control, and
Laboratory use-part 1: General Requirements
EN61326-1: 2006
Electrical Equipment for Measurement, Control and Laboratory use-EMC
Requirements-part 1. General Requirements
EN61000-3-2: 2006+A2:2009
Electromagnetic Compatibility (EMC)-part 3: Limits-Section 2: Limits for Harmonic
Current Emissions (Equipment Input Current less than/equal to 16A per phase)
EN61000-3-3:2008
Electromagnetic Compatibility (EMC)-part 3: Limits-Section 3 Limitation of Voltage
Fluctuations and Flicker in Low-Voltage Supply systems for Equipment with Rated
Current less than or equal to 16A
The tests have been performed in typical configuration.
This conformity is indicated by the symbol CE, i.e."Conformite Europeenne".
7
advertisement
Key Features
- High bandwidth
- Real-time sampling rates
- Variety of measurement functions
- Auto-calibration
- USB connectivity
- VGA output
- RS-232 communication
Related manuals
Frequently Answers and Questions
What is the warranty period for the SDS series oscilloscopes?
How do I perform auto-calibration on the SDS series oscilloscopes?
What is the maximum input voltage for the SDS series oscilloscopes?
advertisement
Table of contents
- 4 Table of Contents
- 5 List of Figures
- 5 List of Tables
- 6 General Safety Summary
- 9 Section 1: General Information
- 9 1.1 Introduction
- 9 1.2 Accessories Supplied
- 9 1.3 Technical Specifications
- 14 1.4 General Technical Specifications
- 15 1.5 Declaration of Conformity
- 16 Section 2: Installation
- 16 2.1 Performing the General Inspection
- 16 2.2 Operating Environment
- 16 2.3 Storage and Transport
- 17 2.4 Packaging
- 17 2.5 Tagging for Service
- 17 2.6 Power Supply Requirement
- 17 2.7 Cleaning Requirements
- 18 Section 3: Test and Calibration
- 18 3.1 Equipment for Testing
- 18 3.2 Test Standard
- 18 3.3 Inspection Items and Methods
- 25 Section 4: Debugging and Calibration
- 25 4.1 Brief Introduction
- 25 4.2 Tools and Devices
- 25 4.3 The Interval Time to Calibration.
- 25 4.4 Auto-calibration
- 25 4.5 Attenuation Compensation Capacitance Calibration
- 26 Section 5: Maintenance
- 26 5.1 Brief Introduction
- 26 5.2 Preparation and Safety Event
- 26 5.3 Circuit Diagram
- 28 5.4 Removal and Installation Procedures
- 44 5.6 Examination and Maintenance
- 46 Section 6: Replaceable Parts
- 46 6.1 Replaceable Parts List
- 46 6.2 Order Information