Press: QUIT
Note: 0000 is not a valid security code. 0000 means that the security code feature is not activated.
The controller will return to the Automatic Mode.
Enabling Security Code
EXAMPLE: Once you have completed operating or making changes to your con troller you can enable the Security Code:
Press: MANUAL ENTER ENTER
The controller returns to the Automatic Mode.
Should you forget to enable the Security Code, the code will automatically become enabled at midnight and no one will be allowed to operate the controller without first entering the security code.
Disabling Security Code (LOCKED Controller)
Once the Security Code feature has been enabled, it will be necessary to enter the
Security Code each time you wish to operate or change your controller.
EXAMPLE: To disable the security code used in the example above,
Press: MANUAL ENTER
SUN
1 9
FRI
6 0
ENTER
The controller returns to the Automatic Mode
Eliminating Security Code
EXAMPLE: To eliminate the Security Code completely, first disable the security code as described above, then:
Press: SETUP 6 times
Press:
0
Press: QUIT
9 0 0 you will see CODE 1 9 6 0
I
PROGRAM
ENTER
The controller returns to the Automatic Mode
SENSOR
that the Sensor is reading "Wet", and one or more programs that are enabled for sensor operation have started. No stations, however, will water due to the wet condition.
51
The RME SENTAR II Controller has the ability to affect irrigation based on an external rain sensor or remote switch. This feature can be programmed on an individual program basis so that one or more programs will cease watering as long as the rain sensor is active.
The external sensor or switch must be of the type which is Closed when there is no rain detected, and opens when rain is detected or it is desired to suspend irrigation.
Most commercial rain sensors are of this type. See the wiring instructions in the
MOUNTING and INSTALLATION section.
EXAMPLE: You have program 4 set up to operate your outdoor lighting, however you also have a rain sensor connected to your RME SENTAR II.
Successively Press: SETUP until you see
SNCR
I
PROGRAM
Press:
SUN
1
MON
2
TUE
3
ENTER you will see
SNCR 123
I
PROGRAM
Press: QUIT The controller will return to automatic mode.
Once programmed in the above manner, the designated program(s) will not turn on any stations unless the rain sensor terminals labeled pins 1 & 2 are shorted together, either by an external switch or the appropriate rain sensor.
If any program is set up to be sensitive to the rain sensor then the status of the rain sensor can be determined by pressing the REVIEW key repeatedly or holding it down until the display shows the word SNSR- followed by WET or DRY. If Dry, the controlled program(s) will operate normally. If Wet, no irrigation will take place on those program(s). Additionally, when a program is scheduled to operate, an asterisk will appear in the leftmost location of the display. If the external sensor has detected rain, or the external switch is Open.
Note: The external sensor is independent of the Rain Switch on the front of the controller. Leave the switch in the Automatic Watering position.
EXAMPLE: To reinstate program 4 into the Sensor Mode,
Successively Press: SETUP until you see
Press:
WED
4
ENTER you will see
SNCR 123
I
PROGRAM
SNCR 1234
I
PROGRAM
Press: QUIT
The controller returns to the Automatic Mode.
52