1 Chapter 1 - Introduction to this Manual. ABB ACS800 CraneDrive Control, ACC800 7.1

Add to My manuals
216 Pages

ACS800 CraneDrive Control is a frequency converter designed for use with cranes. ACC800 7.1 is the latest Crane Application Program for ACS 800 Frequency Converters. This manual provides users with the information necessary to configure and program the ACS 800 CraneDrive Control, including descriptions of the Application Macros, Parameter Groups, and Control Panel operation. The manual also includes safety instructions, start-up procedures, and fault tracing information.

advertisement

1 Chapter 1 - Introduction to this Manual. ABB ACS800 CraneDrive Control, ACC800 7.1 | Manualzz

Chapter 4 – Control Operation

4.5.2

External Control

When the CraneDrive is in External Control, the commands are given either from Fieldbus or I/O (Stand Alone mode). Selection is done with parameter 64.1 Stand Alone Sel. alone

If par. Stand Alone Sel (parameter 64.1) is set True (default value) the

Stand Alone mode is selected.

In external control the digital inputs DI 1 - DI 6 and Ext DI1 – DI4 as well as analog inputs AI1 & AI2 wired directly from joystick and limit switches, are connected to a CRANE function module (except in FB JOYSTICK control mode where joystick signals are sent via fieldbus to CRANE function module, see end of section 5.6.5 for details).

.

The CRANE function module is producing the references and commands like ON/OFF, START and so on.

Fieldbus

When the CraneDrive is in Fieldbus mode (64.1 Stand Alone Sel=False) the commands are given from the supervisory system and received over the fieldbus communication link (see section 5.6..

ACC 800 Firmware Manual 4-11

advertisement

Key Features

  • Programmable via Application Macros and Parameter Groups
  • Control Panel for local monitoring and programming
  • Local Control and External Control options
  • Fieldbus mode operation for remote control
  • Comprehensive Fault Tracing information
  • Start-up Data for motor configuration
  • Safety Instructions for installation and operation
  • Detailed descriptions of CRANEDRIVE parameters

Related manuals

Frequently Answers and Questions

What types of cranes can ACS 800 CraneDrive Control be used with?
The manual focuses on general crane applications but does not specify specific types of cranes. I recommend reviewing the hardware manuals for additional information on compatibility and possible applications.
What are the steps to start up the ACS 800 CraneDrive Control?
The manual outlines a start-up procedure in Chapter 3, which involves setting Start-up Data parameters and checking system operation. You can find more detailed instructions in Chapter 3.
How can I program the ACS 800 CraneDrive Control?
The ACS 800 CraneDrive Control is programmable through a set of parameters organized into logical groups. Refer to Chapter 6 for comprehensive parameter descriptions and Chapter 2 for details on using the control panel.
What are the different control modes for the ACS 800 CraneDrive Control?
The manual describes Local Control and External Control options. Local Control allows for direct control using the keypad, while External Control allows for remote control via external signals. Chapter 4 provides more details on control signals and connections.
How do I troubleshoot faults on the ACS 800 CraneDrive Control?
Chapter 7 of the manual provides step-by-step fault tracing instructions, including a table of common faults, possible causes, and remedies. This information is essential for diagnosing and resolving issues with the CraneDrive.