Physical configuration. Bticino 344613, 344612, 344622
Bticino 344612 is a technologically advanced video internal unit for 2-wire digital systems with a 7" touch screen display. It enables users to manage video door entry calls, communicate with other internal units, activate actuators, and utilize various functions through its intuitive interface. With its modern design and compact size, it seamlessly integrates into any home or office environment.
Advertisement
Advertisement
Classe 300
Installation Manual
Physical configuration
The device must be configured both physically or in
advanced mode , the main differences are
shown in the following table:
Warning: the connection of the configurators to the N - P - M sockets precludes the possibility of using the advanced configuration.
The configuration must be performed with the device disconnected from the power supply.
Before using it, wait for the LEDs to stop flashing.
Available Functions
FAVORITES KEY
QUICK ACTIONS
Private camera
External intercom
Physical Configuration
Possibility of assigning various functions
See “Functions of the M units configurator (Favorites key)”
Preset:
See “Functions of the M tenths configurator (Quick actions)”
The user can rename, delete and add back, only the preset functions
Advanced Configuration
Staircase Light function
Creating quick actions of all functions
The user can decide the quick actions to display in the home page
Pager
Lock
FUNCTIONS The use of the functions is only available through quick actions in the home page
See “Functions of the M tenths configurator (Quick actions)”
Dedicated icons in the home page and customisable, configurable functions
Cameras
Intercom
Activations
10
Classe 300
Installation Manual
Configurators
1 2 3
J1 J2 N
4
P
5
M
Configurator functions
1. J1 = Remove if the additional power supply is present (clamp 1 – 2)
2. J2 = Master/Slave (remove for slave)
3. NN = Device address
4. PP = Address of the EP of which you can open the Door Lock with IU idle, and to which you can send the auto-on command
5. MM = Mode of operation according to the tables on the following pages
M units = Configuration of the FAVORITES capacitive key
M tenths = Configuration of the QUICK ACTIONS in the Home page
If the device is configured physically, the configuration MUST NOT BE MODIFIED using the menu.
11
Classe 300
Installation Manual
Functions of the M units configurator (Favorites key)
J1 J2 N
MM = 0
MM = 1
MM = 2
MM = 3
P M
Staircase Light Control
Direct control of P+1 Door lock
Direct control of P+2 Door lock
Direct control of P+3 Door lock
MM = 4
MM = 5
MM = 6
MM = 7
P+1 direct auto-switching on
P+2 direct auto-switching on
P+3 direct auto-switching on
General Intercom
MM = 8 Internal intercom
MM = 9
Enabling/disabling Professional Studio (Office) function
12
P
P
P+1
P+1
MOD=9
P +2
P+2
P+2
MOD=9
P +3
P+3
P+3
MOD=9
P+1
346210
346210
346210
P+1 P+1
P+1 P+1
MOD=5
P+2
346210
346210
346210
P+2 P+2
P+2 P+2
MOD=5
P+3
346210
346210
346210
P+3 P+3
P+3 P+3
MOD=5
P
P
346210
P
P +1
P
+1
P+1
MOD=9
P+1
MOD=9
P +1
P +2
P +2
MOD=9
P+2
MOD=9
P+2
346210 MOD=9
P +2
P +3
P +3
P +3
MOD=9
P+3
MOD=9
P+3
MOD=9
P+3
MOD=9
Classe 300
Installation Manual
Functions of the M tenths configurator (Quick actions)
The MM - (tenths) physical configurator decides which are the 4 QUICK ACTIONS icons that appear
on the HOME PAGE, and can be activated by touching the display.
J1 J2
P
P
P
P
N
–+ 23
P M
P
P
P
P
+1
+1
+1
+1
–+ 23 P+1
–+ 23 MOD=9
–+ MOD=9 23 P+1
P+1
MOD=9
–+ 23
The possible configurations are shown in the following table
P
P
P +2
–+
–+
23 MOD=9
23 MOD=9
P+2
MOD=9
P
P
P
+3
+3
+3
346210
–+ 23
–+ 23 P+3
MOD=9
MOD=9
P+3
MOD=9
Activation of the EP (configured with P+1) directly without call or activation of the actuator item 346200/346210 (configured with P+1 and
MOD=9).
–+ 23
P +2
346210
346210
P+1
P+1
P+1
P+1
23
346210
EP door lock release (configured with P+1), directly without call, or activation of the actuator item 346200/346210 (configured with P+1 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+1)
P 346210 +3
MOD=5
MOD=5
346210
P+2
P+2
P+2
P+1
346210
P+2
P+2 P+2
MOD=5
MOD=5
P+2 P+2
MOD=5
P+3
P+3
346210
346210
P+3
346210 MOD=5
346210
P+3 P+3
MOD=5
MOD=5
346210
P+4
P+4
P+3
346210
P+4
P+4
P+4 P+4
MOD=5
P+4 P+4
MOD=5
MOD=5
EP door lock release (configured with P+2), directly without call, or activation of the actuator item 346200/346210 (configured with P+2 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+2)
EP door lock release (configured with P+3), directly without call, or activation of the actuator item 346200/346210 (configured with P+3 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+3)
EP door lock release (configured with P+4), directly without call, or activation of the actuator item 346200/346210 (configured with P+4 and
MOD=5), or activation of door lock actuators item 346230 (configured with P+4)
P+4
346210
P+4 P+4
MOD=5
Intercom among apartments in systems with apartment interface item
346850.
Intercom inside the apartment, in systems with apartment interface item
346850, or intercom among apartments in systems without apartment interface.
Internal intercom. It sends the call to all the handsets with the same address.
General intercom. It sends the call to all the handsets of the system.
13
Classe 300
Installation Manual
P
0 1
M
Myself
Poste externe 1
Lock 1
Lock 2
Pager
Camera 1
Lock 1
Lock 2
P
0 2
M P
0 3
M
Myself
Intercom 1
Camera 1
Lock 1
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
N=1 N=2
N=2 N=1
346210
P +1 P+1
MOD=9
P+1
346210
P+1 P+1
MOD=5
14
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P
0 4
M
Intercom 2
Intercom 3
Lock 1
Lock 2
N=1 N=3
N=2
N=2 N=3
N=1
N=3 N=2
N=1
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P
0 5
M
Intercom 2
Intercom 3
Lock 1
Lock 2
N=1
N=2
N=3
N=2
N=1
N=3
N=3
N=1
N=2
N=2 N=1 N=4
N=3 N=5
N=3 N=1 N=4
N=2 N=5
N=4 N=1 N=3
N=2 N=5
N=5 N=1 N=3
N=2 N=4
Classe 300
Installation Manual
P
0 6
M
Intercom 2
Intercom 3
Intercom 4
Intercom 5
N=1 N=2 N=3
N=4 N=5
15
Classe 300
Installation Manual
N=2 N=1 N=4
N=3 N=5
N=3 N=1 N=4
N=2 N=5
N=4 N=1 N=3
N=2 N=5
P
0 7
M
Intercom 2
Intercom 3
Intercom 4
Intercom 5
N=1 N=2 N=3
N=4 N=5
P
0 8
M
Camera 1
Intercom 1
Lock 1
Lock 2
346210
P +1 P+1
MOD=9
N=1 N=2
N=2 N=1
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
P+3
346210
P+3 P+3
MOD=5
P+4
346210
P+4 P+4
MOD=5
Lock 1
Lock 2
Lock 3
Lock 4
P
0 9
M
P+1
346210
P+1 P+1
MOD=5
P+2
346210
P+2 P+2
MOD=5
16
Classe 300
Installation Manual
First switching on
After the device has been configured physically and connected, it is mandatory to perform the customisations using the menu.
Wait for the LEDS to stop flashing and then touch the display to switch it on.
Languages Next
1
English
Français
Italiano
Español
Deutsch
Néerlandais
Português
2
1. Touch the icon for the desired language.
2. Touch to continue.
Back Time and date Next
4
11 d
11 42 m
10 m
2013 y
3
5
3. Touch the icon for the parameter to set (date or time); the icons to increase or decrease the value appear.
4. Touch to set it.
5. Touch to continue.
17
Classe 300
Installation Manual
Now it is possible to display information concerning the configuration of the device
Back
6
Info
N
00
P
00
Master/Slave
Power supply
Firmware ver.
Professional studio
Answering machine
Master
Disabled
1.0.12
Enabled
Enabled
M
20
Display:
A. The configuration parameters.
B. If the device has been set as apartment master or slave.
C. If an additional power sully is present.
D. The firmware version of the device.
E. If the Professional Studio (Office)
function is active.
function is active (only for item 344622).
6. Touch to end the procedure.
End
10:36
Tuesday, 22 April 7
Quick Actions
Pager
Camera 1
Answering machine Memo Settings Lock 1
Lock 2
7. Touch to proceed with the device customisation in the Settings
section.
A
B
C
D
E
F
18
Classe 300
Installation Manual
Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Time and date/Language/Information/Key tone
Volume/Intercom ringtone/Entrance Panel Ringtone/Other ringtones...
Clean monitor/Background/Calibration
Recording Mode/Welcome Message/Record Message...
Activation of Answering machine/ Professional Studio (Office)
General settings
This section contains the general settings and device information.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Time and date
Language
Info
Tone buttons A
A. Enable/disable the sound when a key is pressed.
19
Classe 300
Installation Manual
Time and date
Set the current time and date.
Back Time and date
2
11 d
11 42 m
10 m
2013 y
1
1. Touch the icon for the parameter to set; the icons to increase or decrease the value appear.
2. Touch to set it.
Language
Set the device language.
Back Languages
English
Français
Italiano
Español
Deutsch
Néerlandais
Português
1
1. Touch the icon for the desired language.
20
Classe 300
Installation Manual
Information
It displays information concerning the configuration of the device.
Back Info
N
00
P
00
Master/Slave
Power supply
Firmware ver.
Professional studio
Answering machine
Master
Disabled
1.0.12
Enabled
Enabled
M
00
1
End
Display:
A. The configuration parameters.
B. If the device has been set as apartment master or slave.
C. If an additional power sully is present.
D. The firmware version of the device.
E. If the Professional Studio (Office)
function is active.
function is active (only for item 344622).
1. Touch to go back and save the settings.
A
B
C
D
E
F
21
Classe 300
Installation Manual
Ringtones
This section can be used to associate specific ringtones to certain events, and to adjust their volume.
Back Settings
A
Volume
Generals
Ringtones
Answering machine
Quick Actions
Configuration
Main entrance panel
16
Internal intercom
1
1
More ringtones...
2
A. Adjust the ringtone volume.
1. Touch the event box to which to associate a specific ringtone; the selection arrows appear.
2. Scroll through the available ringtones (16); they will be played back as you scroll through them.
3. Touch to go back and save the settings.
Events to which it is possible to associate ringtones:
Main Entrance Panel: call from the main entrance panel (S0)
Internal intercom: call from an intercom in your apartment.
Other ringtones...
S1, 2, 3 Entrance Panel: call from the SECONDARY Entrance Panel (S1; S2; S3)
External intercom: call from an intercom of another apartment.
Call to the floor: call from the pushbutton outside your entrance door.
Notifications: memo from the switchboard.
22
Classe 300
Installation Manual
Display
This section is used to calibrate, clean the monitor, and to change the background image.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Clean monitor
Background
Calibration
Clean monitor
It’s used to disable the display and the keys for cleaning purposes, without the risk of sending unwanted commands.
A
10
1
A. After touching the corresponding icon, the display remains in stand-by for 10 seconds.
1. during this period, it is possible to clean the monitor and the keys.
Caution: do not clean with solvents, thinners etc. or abrasive products. Only use a soft cloth.
23
Classe 300
Installation Manual
Background
It gives the possibility to change the background image of the device.
Back
Background
2 home
1. Scroll through the available images to get a background preview.
2. Touch to go back and save the settings.
Calibration
It can be used to adjust the touch pressure for the display.
Click the cross
1
1
1. Touch the “cross” symbol on the display as it moves to all 5 positions.
At the end, the Ok icons appears at the corners of the display. Touch it to complete the calibration procedure.
24
Classe 300
Installation Manual
Answering machine (only for item 344622)
This page can be used to set the quality of the videos recorded by the answering machine, or to record, enable, disable the welcome message.
1
Settings Back
Generals
Ringtones
Display
3
Answering machine
Quick Actions
Configuration
Video recording resolution
High
Welcome message
Record message...
2 A
A. Enable/disable the welcome message.
1. Set if video messages must be recorded in high resolution (maximum 25 x 15 sec. messages), or in low resolution (maximum 150 x 15 sec. messages)
2. Touch to record a welcome message.
3. Touch to go back and save the settings.
Warning: the most recent message overwrites the oldest one.
25
Classe 300
Installation Manual
Back
4
Record message
Press to record
4. Touch to start recording, and then record the message.
Back Record message
5
0:20
Press to stop recording
5. Touch to end the recording.
Cancel Record message
6
Save
7
6. Touch to play the message back.
7. Touch to save it.
26
0:20
Press to listen recording
Classe 300
Installation Manual
Quick actions
In this section it is possible to decide which actions to display in home page, selecting them among
.
It is also possible to customise the name
A
Back Settings
1
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Pager
Camera 1
Lock 1
Add quick action
B
1. Touch to add a quick action.
A. Change the name of the quick action.
B. Remove the quick action from the home page.
Back
Cameras
Intercom
Activations
Add quick action
Lock 2
Pager
A
2
2. Select the type of function for which you want to add a quick action.
3 Select the quick action among those available.
A. Available quick action.
B. Quick action already included in the home page.
3
B
27
Classe 300
Installation Manual
Back
Cameras
Intercom
Activations
4
Add quick action
Lock 2
Pager
4. Touch to return to the quick action screen and save the settings.
Back Settings
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Pager
Camera 1
Lock 1
Lock 2
5
5. Touch to modify the name.
Back Confirm
Lock 2A
6 q a w
?123
s z e d x r f c t g v y h b u
7 j n i k m
.
o
6. Enter the new name.
7. Touch to save it.
l p
28
Back
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
Settings
Pager
Camera 1
Lock 1
Lock 2A
Configuration
Back
Generals
Ringtones
Display
Answering machine
Quick Actions
Configuration
1. Touch to enter the configuration.
Settings
Pager
Camera 1
Lock 1
1
Lock 2A
Classe 300
Installation Manual
29
Classe 300
Installation Manual
This password protected section can be used to make the answering machine and office functions available in the home page, therefore giving the user the possibility of enabling or disabling them.
Back Configuration Confirm
Insert installer password
1 q w e r t a s z d x f c
?123
1. Touch to enter the password (default 12345).
2. Touch to save it.
g v y h b u
2 j n i k m
.
o l p
Back Configuration
3
00
N
00
P
Answering machine
Professional studio
3. Touch to make the function available in the home page.
Warning: Further configurations are also available in the advanced mode , which can only
be used if no configurators have been connected to sockets N-P-M.
30
![](http://s1.manualzz.com/store/data/007384819_1-e08e4ece6225ca6aa23a0df0d45e926e-210x147.png)
Advertisement