Rollers and Leveling
This model has 4-point leveling provided by adjustable rollers on the rear and leveling legs on the front. It also has 2 nonadjustable front rollers that are used only for unit positioning.
To level the unit:
1. Turn the 7/16-in. hex nut located above the front rollers to adjust the roller on the rear of the unit. Turn clockwise to raise, counterclockwise to lower.
2. Turn the front legs with a 1-1/4 in. open end wrench to adjust the front of the unit. Turn clockwise to raise, counterclockwise to lower.
Hex Nut
Wheel
Leveling Leg
ICEMAKER
The icemaker is mounted to the upper left wall of the freezer cabinet. Under normal operating conditions, temperatures, door openings, and food load, the icemaker is capable of producing approximately 100 to 130 cubes in a 24-hour period.
Note: The freezer door light switch, located on the back wall of the freezer, also serves as an icemaker interlock (or kill) switch. It will open the circuit to the icemaker any time the freezer drawer is open.
To service the icemaker, refer to GE Publication
31-9063.
Power Switch
Green
Power Light
Water Valve and Water Line
The water valve is mounted to the side of the water filter bracket in the machine compartment.
A plastic water line is routed from under the unit, up the back of the cabinet, into the machine compartment, and to the water valve.
A low-pressure plastic water line supplies water to the icemaker from the water valve. The plastic water line is routed from the water valve, out the back of the machine compartment, down the back of the cabinet to the fill tube grommet. The icemaker fill tube is also plastic.
To Replace the Water Valve
Note: Some water may leak from the water supply line and valve when they are disconnected.
1. Shut off the water supply to the freezer.
Water Valve
Water Filter Bracket
Feeler Arm
Icemaker
P0003393
2. Raise the machine compartment cover panel.
3. Remove 2 Phillips screw attaching the water valve cover.
4. Remove 2 Phillips screw attaching the water valve to the filter bracket.
5. Disconnect the wiring harness connector and
2 water lines from the water valve and remove.
Water Valve
To Replace the Water Line from the Water Valve to the Fill Tube Grommet
Note: Some water may leak from the water supply line and valve when they are disconnected.
1. Shut off the water supply to the freezer.
2. Remove the unit from its installation.
3. Remove 14 (1/4-in.) screws and the metal access cover.
4. Disconnect the water line at the quick connector by pushing in the white collar on the quick connector while pulling the water line out.
5. Loosen the clamp at the fill tube grommet and remove the water line.
Screw
Access Cover
P
P0003413