TABLE DATA ERRORS. Fagor CNC 8055 para otras aplicaciones, CNC 8055 for lathes, CNC 8055 para tornos, CNC 8055 for other applications
Add to My manuals100 Pages
advertisement
Error solution
TABLE DATA ERRORS
‘CHECKSUM ERROR GENERAL PARAMETERS Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR SPINDLE PARAMETERS Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR 2nd SPINDLE PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR AUX. SPINDLE PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR SERIAL LINE 1 PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR SERIAL LINE 2 PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR HD/ETHERNET PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR USER PARAMETERS Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR OEM PARAM. Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR PLC PARAMETERS Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR ZERO OFFSET TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR PASSWORD TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR AXIS * PARAMETERS Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR:TOOL TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR TOOL OFFSET TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR MAGAZINE TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR M FUNCTION TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR LEADSCREW * TABLE Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR CROSS COMP. TABLE * Load CARD A? (ENTER/ESC)’
‘CHECKSUM ERROR GEOMETRY TABLE Load CARD A? (ENTER/ESC)’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
Certain table data has been lost (possible RAM error) and there is a table saved in
CARD A.
Pressing [ENTER] copies the table saved in CARD A to RAM memory. If the error persists, contact the service department.
·T· Model
Ref.1507
·87·
Error solution
‘ERROR:GENERAL PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:SPINDLE PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:SPINDLE-2 PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:AUX. SPINDLE PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:SERIAL-LINE-1 PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:SERIAL-LINE-2 PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘CHECKSUM ERROR:HD/ETHERNET PARAMETERS Initialize? (ENTER/ESC)’
‘CHECKSUM ERROR:USER PARAMETERS Initialize? (ENTER/ESC)’
‘CHECKSUM ERROR:OEM PARAMETERS Initialize? (ENTER/ESC)’
‘ERROR:PLC PARAMETER CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:ZERO OFFSET TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:CODE TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:AXIS PARAMETER CHECKSUM Reset? (ENTER/ESC)’
·T· Model
Ref.1507
‘ERROR:TOOL TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:TOOL OFFSET TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:TOOL MAGAZINE TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:M FUNCTION TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:AXIS LEADSCREW TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR:CROSS COMP. TABLE CHECKSUM Reset? (ENTER/ESC)’
‘ERROR: GEOMETRY TABLE CHECKSUM Reset? (ENTER/ESC)’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
Certain table data has been lost (possible RAM error) and there is no table saved in
CARD A.
Pressing [ENTER] loads the tables with CNC’s default values. If the error persists, contact the Service Department.
‘CHECKSUM ERROR GENERAL PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR SPINDLE PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR SPINDLE 2 PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR AUX SPINDLE PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR SERIAL LINE 1 PARAM. Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR SERIAL LINE 2 PARAM. Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR HD/ETHERNET PARAM. Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR USER PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR OEM PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR PLC PARAMETERS Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR ZERO OFFSET TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR ZERO CODE TABLE Load HARD DISK? (ENTER/ESC)’
‘ERROR:* AXIS PARAMETER CHECKSUM HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR:TOOL TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR:TOOL OFFSET TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR:TOOL MAGAZINE TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR:M FUNCTION TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR * AXIS LEADSCREW TABLE Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR CROSS COMP. TABLE * Load HARD DISK? (ENTER/ESC)’
‘CHECKSUM ERROR GEOMETRY TABLE Load HARD DISK? (ENTER/ESC)’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
Certain table data has been lost (possible RAM error) and there is a table saved in
HARD DISK.
Pressing [ENTER] copies into RAM the table saved in the HARD DISK. If the error persists, contact the Service Department.
·88·
Error solution
‘Wrong * leadscrew table. Press key’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
There is some erroneous data in the parameters of the leadscrew compensation table.
The definition of the points of the table must meet the following requirements:
• The points of the table must be ordered according to their position on the axis, starting from the most negative or less positive point to be compensated.
• The machine reference point must have no error (zero).
• The error difference between consecutive points cannot be greater than the distance between them.
‘Wrong * cross compensation table. Press key’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
There is some erroneous data in the parameters of the cross compensation table.
The definition of the points of the table must meet the following requirements:
• The points of the table must be ordered according to their position on the axis, starting from the most negative or less positive point to be compensated.
• The machine reference point must have no error (zero).
‘Incorrect cross compensation table parameters’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
The parameters indicating the axes involved in the cross compensation are defined wrong.
Maybe a nonexistent axis has been defined or the affected axis (to be compensated) and the one affecting it are the same.
‘Wrong axis or spindle parameters sercosid’
DETECTION
CAUSE
SOLUTION
During CNC start-up.
The servosid parameters have not been entered correctly.
The rules of sercosid parameters are:
• They must begin with number 1.
• They must be consecutive.
• They cannot be repeated.
·T· Model
Ref.1507
·89·
Error solution
·T· Model
Ref.1507
·90·
advertisement