8
Installation
OVERHEAD CLEARANCE PROVISIONS
When installing the Esprit SE IP system, allow for sufficient clearance between the top of the unit and overhead obstructions. This will prevent interference when the enclosure is driven to its maximum elevation of 33 degrees.
33.0
°
A
B
C
D
D
D
C
C
Figure 1. Clearance for Overhead Obstruction
Without Wiper
42.5 cm
(16.6 inches)
23.9 cm
(9.4 inches)
18.1 cm
(7.1 inches)
10.7 cm
(4.2 inches)
With Wiper
42.9 cm
(16.9 inches)
24.6 cm
(9.7 inches)
19.2 cm
(7.6 inches)
11.7 cm
(4.6 inches)
C1327M-A (5/13)
INSTALLING THE POWER MODULE
1. Remove the transformer from the base of the power module by loosening the four Phillips captive screws and lifting the module.
Figure 2. Removing the Transformer Module
ì
Phillips Captive Screws
î
Transformer
ï
Base
2. Attach the base of the system to an Esprit SE IP mount: a.
Apply a drop of Loctite ® thread compound (supplied) to each of the three mounting holes and 10-32 x 1/2-inch flathead screws
(supplied).
WARNING: Failure to apply Loctite to the mounting holes may increase the risk of damage to the unit.
b.
Align the mounting holes on the base with the holes on the mount.
C1327M-A (5/13) 9
c.
Attach the base of the system to the mount using the three flathead screws and washers (supplied).
Figure 3. Attaching the Base to a Mount
ì
10-32 x 1/2-inch Flathead Screws
î
Base
ï
Mount
3. Make all cable and wire connections, and then route the wires and network cable through the center of the Esprit SE IP mount.
4. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation.
5. Models with 120/230 VAC only: Set the 120/230 voltage selector switch on the transformer to the appropriate voltage.
10
Figure 4. Reinstalling the Transformer Module
ì
Voltage Selector Switch
6. Install the Esprit SE IP mount; refer to the installation manual supplied with the mount for instructions.
C1327M-A (5/13)
CONNECTING THE NETWORK CABLE AND WIRES
1. Attach the supplied RJ-45 female-to-female couplier to the network cable attached to the power module.
2. Connect the other end of the couplier to a network cable (not supplied).
3. Connect the power wires using the two supplied clamp connectors.
Table A. 24 VAC Wiring
Wire
White wire
White wire
Green wire
Description
Input (AC Line)
AC Neutral
Ground
Table B. 120/230 VAC Wiring
Wire
Black wire
White wire
Green wire
Description
Input (AC Line)
AC Neutral
Ground
4. (Optional) Connect the wiring for AUX2.
Table C. AUX2 Wiring
Wire
Red wire
Black wire
Description
Auxiliary
Ground
5. Turn on the power. If the LED turns red, turn off the power, and proceed with installation.
C1327M-A (5/13) 11
INSTALLING THE PAN AND TILT MODULE
1. Connect the male system connector, located on the bottom of the pan/tilt, to the female system connector, located on the transformer module.
2. Align the screw hole of the pan/tilt with the screw hole of the power module.
3. Attach the pan/tilt to the base with three 1/4-20 nuts and washers (supplied).
Figure 5. Installing the Pan/Tilt Module
ì
Male System Connector
î
Female System Connector
12 C1327M-A (5/13)