J-200
11.6 Programming the CLEARRAY (Ultraviolet) Water Purification
System
A. Programming the CLEAR RAY System (U) or Corona Discharge
Ozone (O3)
Press and hold the Jets pump 1 (
1
) and Cooler ( ) button at the same time for 3 seconds to enter the sanitizing system program. The screen will display one of the two menus below:
CLEARRAY Menu
Press
O3 Menu
Press or or
1. If the LED screen is displaying “U” then pressing the Jets pump
1 will change the sanitizing system from “U” to “O3” and exit the programming menu. If the LED screen is displaying “O3” then pressing the Jets pump 1 will change the sanitizing system from “O3” to “U” and exit the programming menu.
Note: For the O3 option the “=” disables the duration countdown timer.
2. If you do not wish to change the option do not press any buttons and after 10 seconds the display will return to the main menu.
Note: If the CLEAR RAY System has been selected, when the time allotted has expired (365 days) the display screen will flash between the water temperature and “blb.” At this time the UV bulb must be replaced, the quartz tube must be cleaned and the duration countdown timer needs to be reset.
30
J-200
B. Resetting the duration countdown timer (CLEARRAY® System only)
Once the duration countdown timer for the CLEAR RAY System has reached zero, you will need to reset it, replace the UV bulb and clean the quartz tube.
To reset the duration countdown timer:
Press Press
1
1. Press and hold Jets pump 1 (
1
) and Cooler ( ) at the same time for 3 seconds.
2. Press the Warmer ( ) button until the display shows “0.”
3. If the timer has reached “0,” pressing the Jets pump 1 (
1
) button will reset the timer to 365 days. If the timer is not at “0” pressing the Jets pump 1 button will not reset it.
Note: If the spa power is interrupted, the duration countdown timer is not affected. The number of days remaining is stored in the memory and will continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it: a. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
b. Press the Warmer button to scroll to “U.” c. Press the Jets pump 1 button to switch from “U” to “O3.” d. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
e. Press the Warmer button to scroll to “O3.” f. Press the Jets pump 1 button to switch from “O3” to “U.” The timer has been reset to 365 days.
31
advertisement
Related manuals
advertisement
Table of contents
- 5 1.0 Important Spa Owner Information
- 5 2.0 FCC Notice
- 6 3.0 Important Safety Instructions for all Spa Owners
- 10 Entrapment Risk
- 11 3.2 Hyperthermia
- 12 Important CSA Safety Instructions (Canada Only)
- 12 General Electrical Safety Instructions
- 13 4.0 Choosing A Location
- 14 Outdoor Location
- 14 Indoor Location
- 15 5.0 General Electrical Safety Instructions
- 16 6.0 Power Requirements
- 18 7.0 Electrical Wiring Instructions
- 21 8.0 Spa Fill Up Procedure
- 26 9.0 Control Functions
- 26 Control Panel
- 27 General Spa Features and Controls
- 28 General Spa Features and Controls (J-235/J-245/J-275)
- 29 10.0 Operating Instructions
- 29 10.1 Setting Water Temperature
- 30 10.2 Activate Jet Pumps
- 30 10.3 Multi-Colored LED Light System Operation
- 30 10.4 Adjusting Individual Jet Flow
- 30 10.5 Selecting Desired Massage Action
- 31 10.6 Air Controls
- 31 J-280)
- 32 11.0 Automatic Filtration Cycles
- 32 11.1 Standard Filtration/Heating Modes
- 32 11.2 Economy Filtration/Heating Modes (All Models)
- 32 11.3 Lock Modes - L1-L3 (All Models)
- 32 11.4 Selecting The Filtration/Heating Mode
- 32 11.5 Filtration Modes for Spas
- 34 Purification System
- 36 12.0 Spa Maintenance
- 36 12.1 Cleaning The Filters
- 40 12.2 Draining and Refilling
- 40 12.3 Pillow Care
- 41 12.4 Cleaning The Spa Interior
- 41 12.5 Vinyl Cover Care and Maintenance
- 41 12.6 Maintaining The Synthetic Cabinet
- 42 12.7 Winterizing
- 43 12.8 Restarting Your Spa in Cold Weather
- 43 13.0 Water Quality Maintenance
- 44 13.1 pH Control
- 44 13.2 Sanitizing
- 45 ® Water Purification System
- 46 Tube Maintenance
- 49 14.0 Error Conditions/Error Messages
- 49 14.1 Panel Displays COL
- 49 14.2 Panel Displays ICE
- 49 14.3 Panel Displays SN
- 49 14.4 Panel Displays SN
- 49 14.5 Panel Flashes FL1 or FL
- 50 14.6 Panel Displays OH
- 50 14.7 Panel Displays (- - -)
- 50 14.8 Panel Displays BLB
- 50 15.0 Troubleshooting Procedures
- 50 15.1 None of the Components Operate (e.g. Pump, Light)
- 51 15.2 Pump Does Not Operate But Light Does
- 51 15.3 Poor Jet Action
- 51 15.4 Water is Too Hot
- 51 15.5 No Heat
- 52 16.0 Circuit Board Diagrams
- 52 16.1 North American J-235, J-245, J-275 and J-280 Models
- 53 16.2 North American J-210 Convertible Models
- 54 16.3 Export 50 Hz J-235, J-245, J-275 and J-280 Models
- 55 16.4 Export 50 Hz J-210 Models
- 56 17.0 Optional BLUEWAVE® Spa Stereo System
- 57 17.1 Pairing the Remote and Stereo
- 57 17.2 Audio Settings
- 59 17.3 Wireless Remote Control Functions
- 60 17.4 Electronic Device Connections and Functions
- 63 17.5 Wireless Remote Battery Replacement Procedure
- 63 17.6 Bluewave Spa Stereo System Specifications
- 64 17.7 Stereo Cautions