General Operation Information. Jacuzzi FUZ7260CCR5CHY, FUZ7242CCR5IWW

General Operation Information. Jacuzzi FUZ7260CCR5CHY, FUZ7242CCR5IWW


Add to My manuals
77 Pages

advertisement

General Operation Information. Jacuzzi FUZ7260CCR5CHY, FUZ7242CCR5IWW | Manualzz

General Operation Information

All bathtubs manufactured by Jacuzzi Luxury Bath are designed for “fill and drain,” which means the bathtub should be drained after each use and filled with fresh water by the next bather. This is a health precaution, as these bathtubs are not designed to hold water continuously like pools or spas.

Two control panel types are available for the Luxury

Salon Spa series. Refer to details below:

J4 Luxury Electronic Control Panel:

Operational instructions for this panel is listed

Optional J5 Luxury LCD Control Panel:

Operation instructions for this panel are outlined in

the supplemental guide provided in your warranty

pack. Refer to this document for complete operation

details (P/N GU47000).

Close the drain and fill the bathtub until water is at least

1˝ to 2˝ (25mm to 51mm) above the highest jet (see water line indicated in the illustration). Do not turn on the whirlpool system at any time if the jets are not completely immersed in water. Running the whirlpool system when there is insufficient water in the bathtub could result in water spraying outside the bath area. Running the whirlpool system without sufficient water will damage the recirculating pump.

When exiting the bathtub, the water level will drop below the jets which could result in water being sprayed out of the unit. To prevent this, you must turn unit OFF before exiting bathtub.

Blower Operation

ON: Press the blower button once to turn the blower ON.

The indicator light(s) at right will illuminate brightly. The blower is on a timer and will operate for 20 minutes.

OFF: Press the blower button a second time to turn the blower OFF.

The last blower setting used is remembered by the system and will automatically resume upon next use.

When the blower is turned off, operation does not immediately cease. There is a delay of 15-20 seconds to allow the blower to cool down. The unit is shutting down, as indicated by the blinking of indicator lights.

If in chromatherapy lighting, or whirlpool, mode

(indicator lights are dim), you will need to press the blower button once to resume blower operation mode and then a second time to turn the blower power off.

Page 16 www.jacuzzi.com

Jet Air

J4 Control Panel

Main Menu

POWER

J5 Control Panel

Air

These lights will be blinking

Salon™ Spa Bath

Fill to at least 1˝ to 2˝ above highest jet

Installation and Operation

Salon™ Spa Bath

Increase Speed

Press the (+) button to increase blower speed.

There are 8 blower intensities. Each push and release of the (+) button will increase blower intensity through 8 incremental steps. The indicator lights display intensity of blower power.

1 light on = Low settings 1 and 2

2 lights on = Medium low settings 3 and 4

3 lights on = Medium high settings 5 and 6

4 lights on = High settings 7 and 8

Alternately, if the (+) button is depressed and held, the blower intensity will increase through each of the 8 blower intensities, stopping when the button is released.

Low

1-2

Medium

Low 3-4

Medium

High 5-6

High

7-8

Decrease Speed

Press the (-) button to decrease blower speed.

There are 8 blower intensities. Each push and release of the (-) button will decrease blower intensity through 8 incremental steps. The indicator lights display intensity of blower power.

4 lights on = High settings 7 and 8

3 lights on = Medium low settings 5 and 6

2 lights on = Medium high settings 3 and 4

1 light on = Low settings 1 and 2

Alternately, if the (-) button is depressed and held, the blower intensity will decrease through each of the 8 blower intensities, stopping when the button is released.

High

7-8

Medium

High 5-6

Medium

Low 3-4

Low

1-2

Your air bath is designed to provide different massage experiences based on selected blower intensity. You can generally expect the following:

Setting 1 – only the Thermal Lumbar Comfort (TLC) areas (inverted U on backrests) will be active

Setting 2 – the TLC area and most of the perimeter will be active

Setting 3 – the TLC area and all of the perimeter will be active

Setting 4 – all air channels will be active, including TLC, perimeter, and bottom

Settings 5-8 – all air channels active

Wave Mode

With the blower ON, press the wave button to cycle the blower from its minimum setting to a user defined maximum.

The cycle from minimum to maximum completes in 6.4 seconds. The indicator lights will display the blower intensity as it cycles from minimum to maximum. To turn off wave mode, press the wave button.

Press the (+) or (-) button while in wave mode to set the maximum intensity level from 50% - 100%. There is a 5 second delay after adjusting the maximum intensity level before changes are observed.

Installation and Operation www.jacuzzi.com

Page 17

advertisement

Related manuals

Download PDF

advertisement

Table of contents