Controller Operation
If the assignment digit is valid, three beeps are heard and the controller returns to Normal mode.
If the assignment digit is invalid, a long beep sounds and the controller waits for another assignment digit to be entered.
4.9.16
PIN Code Length/Factory Default Settings
You must be very careful before using this command!
Changing the PIN code length also erases the entire memory contents, including all user and special codes, and returns all codes to their factory default settings.
To change the PIN code length:
1.
Enter Programming mode.
Green
2.
Select the desired PIN code length as follows:
00 – Returns to factory defaults and sets a 4-digit code
05 – Returns to factory defaults and sets a 5-digit code
06 – Returns to factory defaults and sets a 6-digit code
08 – Returns to factory defaults and sets a 4–8 digit code
When choosing the 4–8 option, please note that you should either enter zeros before the code, or press # at the end (for example if your code is 12345, enter either 00012345 or
12345# ).
Both LEDs flash red.
3.
Enter your 4-digit Programming code.
Red Red
If the Programming code is valid, all memory is erased. You hear three beeps and the controller returns to Normal mode.
If the Programming code is invalid, you hear a long beep and the controller returns to Normal mode without erasing the memory contents.
AYC-E60 Installation and Programming Manual 59
advertisement
Related manuals
advertisement
Table of contents
- 9 Introduction
- 9 Box Content
- 10 Ancillary Equipment
- 11 Installation
- 11 Mounting
- 12 Wiring
- 12 Wiring the Unit as a Reader
- 13 Wiring the Unit as a Controller
- 16 Reader Operation
- 16 General
- 17 Programming as a Reader
- 18 Entering Programming Mode
- 19 Exiting Programming Mode
- 19 Selecting Keypad Transmission Format
- 24 Selecting HID Prox Card Transmission Format
- 25 Selecting Rosslare Proximity Card Transmission Format
- 27 Changing the Programming Code
- 27 Changing the Facility Code
- 28 Setting the Backlight Behavior
- 29 Setting the Credential Format
- 29 Return to Factory Default Settings
- 30 Replacing a Lost Programming Code
- 31 Controller Operation
- 31 Normal, Secure, and Master Users
- 32 Modes of Operation
- 32 Normal Mode
- 33 Bypass Mode
- 33 Secure Mode
- 33 Changing the Modes of Operation
- 35 Auxiliary Input and Output
- 35 Door Alarms
- 35 Internal Case and Back Tamper
- 35 Lockout Feature (Keypad/Card Tamper)
- 36 REX Function
- 36 Secured Intelligent Power Supply
- 37 Programming as a Controller
- 38 Entering Programming Mode
- 38 Exiting Programming Mode
- 39 Changing Lock Strike Code
- 39 Changing Auxiliary Code
- 40 Changing the Programming Code
- 41 Changing the Normal/Secure Code
- 42 Release Time
- 43 Defining the Auxiliary Input and Output
- 49 Setting the Lockout Feature
- 50 Setting the Backlight Behavior
- 50 Selecting the Credential Format
- 51 Enrolling Primary and Secondary Codes
- 54 Deleting Primary and Secondary Codes
- 57 Relay Codes Assignment
- 59 PIN Code Length/Factory Default Settings
- 60 Replacing a Lost Programming Code
- 60 Replacing a Lost Normal/Secure Code
- 61 Technical Specifications
- 63 Declaration of Conformity
- 64 Limited Warranty