Technical Specifications. Rosslare AYC-E60 65 Pages
Technical Specifications. Rosslare AYC-E60
advertisement
Technical Specifications
5.
Technical Specifications
Electrical Characteristics
Power Supply Type
Operating Voltage Range
Linear (recommended)
6–16 VDC
(when used as a controller, provided by the secured intelligent power supply)
Input Current Standby (12 VDC) 110 mA
Input Current Max (16 VDC) 130 mA
LED Control Input
Tamper Output
Dry contact N.O.
Open collector, active low, 32 mA max sink current
Cable Distance to Host Controller Up to 150 m (500 ft) using an 18-AWG cable
Max. Proximity Card Read
Range*
Rosslare proximity: 40 mm (1.6)
HID Prox: 40 mm (1.6 in.)
Proximity Card Modulation
Proximity Card Compatibility
Rosslare proximity/HID Prox at 125 kHz
Rosslare proximity/HID Prox cards
Card Transmit Format (Reader) Rosslare proximity cards: Wiegand 26-bit, or Clock & Data
HID cards: According to card type
Programmable PIN code formats Keypad Transmit Format
(Reader)
LED Indicators
Communication
Two tri-colored LEDs
Data1/C1, Data0/C2–open collector,
5 V termination
* Measured using a Rosslare proximity card or equivalent. Range also depends on electrical environment and proximity to metal.
AYC-E60 Installation and Programming Manual 61
Technical Specifications
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
-22°F to 150°F (-30°C to 65°C)
0 to 95% (non-condensing)
Weather-resistant, meets IP-65, epoxy potted, suitable for indoor and outdoor use
Physical Characteristics
Size
(Height x Width x Depth)
Weight
155 x 44 x 9 mm (6.1 x 1.7 x 0.4 in.)
143 g (5.0 oz)
62 AYC-E60 Installation and Programming Manual
advertisement
Related manuals
advertisement
Table of contents
- 9 Introduction
- 9 Box Content
- 10 Ancillary Equipment
- 11 Installation
- 11 Mounting
- 12 Wiring
- 12 Wiring the Unit as a Reader
- 13 Wiring the Unit as a Controller
- 16 Reader Operation
- 16 General
- 17 Programming as a Reader
- 18 Entering Programming Mode
- 19 Exiting Programming Mode
- 19 Selecting Keypad Transmission Format
- 24 Selecting HID Prox Card Transmission Format
- 25 Selecting Rosslare Proximity Card Transmission Format
- 27 Changing the Programming Code
- 27 Changing the Facility Code
- 28 Setting the Backlight Behavior
- 29 Setting the Credential Format
- 29 Return to Factory Default Settings
- 30 Replacing a Lost Programming Code
- 31 Controller Operation
- 31 Normal, Secure, and Master Users
- 32 Modes of Operation
- 32 Normal Mode
- 33 Bypass Mode
- 33 Secure Mode
- 33 Changing the Modes of Operation
- 35 Auxiliary Input and Output
- 35 Door Alarms
- 35 Internal Case and Back Tamper
- 35 Lockout Feature (Keypad/Card Tamper)
- 36 REX Function
- 36 Secured Intelligent Power Supply
- 37 Programming as a Controller
- 38 Entering Programming Mode
- 38 Exiting Programming Mode
- 39 Changing Lock Strike Code
- 39 Changing Auxiliary Code
- 40 Changing the Programming Code
- 41 Changing the Normal/Secure Code
- 42 Release Time
- 43 Defining the Auxiliary Input and Output
- 49 Setting the Lockout Feature
- 50 Setting the Backlight Behavior
- 50 Selecting the Credential Format
- 51 Enrolling Primary and Secondary Codes
- 54 Deleting Primary and Secondary Codes
- 57 Relay Codes Assignment
- 59 PIN Code Length/Factory Default Settings
- 60 Replacing a Lost Programming Code
- 60 Replacing a Lost Normal/Secure Code
- 61 Technical Specifications
- 63 Declaration of Conformity
- 64 Limited Warranty