Edit Communication

This command changes communication port parameters. The command format is:

S

ED-COM:[<tid>]:<aid>:<ctag>:::<spec_block>;

4

184

Aid Value

COM-a a = 1 a = 2

Item Addressed

Serial communication port 1 (COM1)

Serial communication port 2 (COM2) a = 3 Serial communication port 3 (Craft) a = 5001 Ethernet user interface port 5001 (Note 1) a = 5002 Ethernet user interface port 5002 (Note 1) a = 5003 Ethernet user interface port 5003 (Note 1) a = 5004 Ethernet user interface port 5004 (Note 1) a = 5551 Ethernet element manager interface port 5551

(Note 2)

Notes:

1. Ethernet ports 5001, 5002, 5003, and 5004 are set up to act as serial communication ports, so that a terminal program on a computer connected to these ports can communicate effectively.

2. Ethernet port 5551 is set up to allow an element manager to connect with it for TL1 commands and responses. TL1 autonomous messages are sent through port 5550, which connects to an element manager to send one or a group of autonomous messages, then disconnects. Port 5550 is not to be reconfigured.

TimeSource 3500

TL1 Reference

097-72050-01 Issue 7: August 2003

S S S S S S S S S S S S S S S S S S S S S S S S S S S S S

Edit Communication (cont’d)

The parameters which can be entered in the <spec_block> are listed below. For any specific <aid> entered in a command, only certain parameters are valid. For each valid parameter, choose the appropriate value from the Value column. When entering multiple parameters, separate the parameters with commas .

Aid Parameter Value Description

COM-a MONMSG=b

KEEPALIVE=b b = ALW b = INH b = 1 to

255

View messages from all ports

View messages from this port only

Inactive minutes until the unit sends a COMPLD message to keep the connection from being closed b = 0 No COMPLD message is output

ENDOFTEXT=b b = 1 to 9F Hex code at end of all responses

ECHO=b

COMPRI=b b = 0 b = ALW

No hex code at end of responses

Echoes characters received so they appear on the user’s screen as typed

Local echo is disabled b = INH b = ALW0 TL1 commands and responses, no autonomous messages sent b = ALW1 TL1 commands and responses, autonomous messages b = ALW2 TL1 commands and responses, autonomous messages whether logged on or not b = INH Closes connection, logs off any user (if logged on), and keeps port from use.

Releases a telnet session from an Ethernet port (a port cannot close itself)