Overview. Allen-Bradley PowerFlex 755 IP00

Add to My manuals
78 Pages

advertisement

Overview. Allen-Bradley PowerFlex 755 IP00 | Manualzz

4

PowerFlex 755 IP00, NEMA/UL Open Type Drive

Overview

Selecting and Integrating an IP00 System

The following steps will guide you in planning and installing a PowerFlex 755

IP00, NEMA/UL Open Type drive.

1. Considerations

Drive size (Hp & V AC), required accessories/options (HIM, comms, etc.)

• Ingress protection of system

• Mounting orientation of drive

Cooling method, venting orientation, alignment of venting

Control pod mounting location

• Cabling entry/exit scheme and cable routing provisions

• Roll-out cart required

Personnel safety and necessary tooling

2. Selection

• Select and purchase enclosure with sub-panel and ingress accessories (page

16 )

• Select and purchase drive and corresponding drive options (see 750-TD001 )

Select and purchase pod and corresponding cables (page 10

or page

14 )

Select and purchase field termination kits (page 10

or page 14

)

Select and purchase appropriate mounting kits (drive mounting & floor - page 10

or page 14 )

Select and purchase door fans (pages 20

… 21

)

Select and purchase necessary wire and cabling (pages 45

&

59 )

3. Prepare the Enclosure

Create ventilation openings, mount door fans (pages 17

… 21

)

• Provisions for accessories (HIM cradle, etc. - see 750-TD001 )

• Fabricate and mount inlet and outlet plenums (pages

17 …

19

)

Drill sub-panel(s) (page

39 & page

40 )

Mount field termination kit, mounting brackets, and floor kit (page 39

& page 40 )

• Mounting of customer specified accessories

• Remote mounting of control pod (if specified - see 750-IN015 )

Mount sub-panel(s)

4. Power and Ground Wiring

Ensure proper grounding (page 45 )

Position & secure movable L-brackets (page 49 )

• Properly terminate power cables (page

48 )

• Attach power cabling (page

48 )

5. Roll-in and Secure the Drive Unit

Raise drive unit to vertical orientation (page

37

)

• Position roll-out cart (see 750-IN001 )

• Lift drive unit onto cart (see 750-IN001 )

Roll drive unit into cabinet and secure (see 750-IN001 )

6. Control Wiring

Mount control pod into drive (if specified - page 42 )

Verify control transformer voltage (page 41

)

• Ensure proper cable routing (page

58 )

• Attach pod power and fiber optic cables (page

58

)

Install real time clock battery and HIM cable (page 60 )

Install remaining control wiring (pages 59 …

66 )

Verify correct torque on all fasteners and connectors

7. Commission the System

Rockwell Automation Publication 750-IN020D-EN-P - May 2017

PowerFlex 755 IP00, NEMA/UL Open Type Drive

1…3

20G 1

4 a b

Code

20G

1

5 c a

Drive

Type

PowerFlex 755

T

6 d

Code

1

4 b

Future Use c

Input Type

Description

AC Input w/Precharge

DC Input w/Precharge

Code

C

D

E

F

Code

T d

Enclosure

Description

IP00, UL Open Type without Control POD e

Voltage Rating

Voltage

400V AC / 540V DC

480V AC / 650V DC

600V AC / 810V DC

690V AC / 932V DC (not UL listed)

Catalog Number Explanation

e

7 8…10 11

D 485 A f1…f2 g

Position

12

N h

13

0 f1

Code

C460

C540

C567

C650

C750

C770

C750

C770

C567

C770

C460

C540

C567

C650

ND Rating

400V AC / 540V DC, 50 Hz Input

Amps kW

Quantity

Required

460

540

250

315

1

1

567

650

750

770

910

1040

1090

1175

1465

1480

1590

2150

315

355

400

400

500

560

630

710

800

850

900

1250

1

1

1

1

2

2

2

2

2

2

3

3

Equivalent

Frame Size

8

9

10

To achieve the extended ratings listed for Frames 9 and 10, the base

Frame 8 drive must be paralleled 2 or 3 times. Refer to the Drive

Rating tables on pages 8, 9, 12, and 13 for detailed information.

14

N

1 5

N

16

N

17

N

18

N f3

Code

E295

E355

E395

E435

E460

E510

E460

E510

E395

E510

E295

E355

E395

E435

ND Rating

600V AC / 810V DC, 60 Hz Input

Amps Hp

Quantity

Required

295

355

300

350

1

1

395

435

460

510

595

630

760

825

900

980

1110

1430

400

450

500

500

600

700

800

900

950

1000

1100

1400

1

1

1

1

2

2

2

2

2

2

3

3

Equivalent

Frame Size

8

9

10

To achieve the extended ratings listed for Frames 9 and 10, the base

Frame 8 drive must be paralleled 2 or 3 times. Refer to the Drive

Rating tables on pages 8, 9, 12, and 13 for detailed information.

Code

A

J g

Filtering and CM Cap Configuration

Filtering Default CM Cap Connection

Yes

Yes

Jumper Removed

Jumper Installed h

Code

N

Dynamic Braking §

Internal Resistor

No

§ Not available on Frames 8…10.

Internal Transistor

No f2

Code

D430

D485

D545

D617

D710

D740

D430

ND Rating

480V AC / 650V DC, 60 Hz Input

Amps Hp

Quantity

Required

617

710

740

800

430

485

545

350

400

450

500

600

650

700

1

2

1

1

1

1

1

Equivalent

Frame Size

8

D485

D545

D617

D710

D740

D545

D740

960

1045

1135

1365

1420

1525

2070

800

900

1000

1100

1250

1350

1750

2

2

2

2

2

3

3

9

10

To achieve the extended ratings listed for Frames 9 and 10, the base

Frame 8 drive must be paralleled 2 or 3 times. Refer to the Drive

Rating tables on pages 8, 9, 12, and 13 for detailed information. f4

Code

F265

F330

F370

F415

F460

F500

F265

ND Rating

690V AC / 932V DC, 60 Hz Input (not UL listed)

Amps kW

Quantity

Required

Equivalent

Frame Size

415

460

500

590

265

330

370

250

315

355

400

450

500

560

1

1

1

1

1

1

2

8

F330

F370

F415

F460

F500

F370

F500

650

710

765

795

960

1040

1400

630

710

750

800

900

1000

1400

2

2

2

2

2

3

3

9

10

To achieve the extended ratings listed for Frames 9 and 10, the base

Frame 8 drive must be paralleled 2 or 3 times. Refer to the Drive

Rating tables on pages 8, 9, 12, and 13 for detailed information.

Rockwell Automation Publication 750-IN020D-EN-P - May 2017 5

advertisement

Related manuals