Basic Operation and Installation
3.6
Package Contents and Installation
Before you install your new SX103X switch, unpack the system and check to make sure that all the parts have been sent, check this against the parts list below. Check the parts for visible damage that may have occurred during shipping.
The switch comes packed with the following items:
• 1 X – switch
• 1 X – installation kit
• 1 X – power cable for each PS unit – Type C13-C14
• See “Replacement Parts Ordering Numbers” on page 59 to order power cords for various countries
• A single power cord for each power supply unit can be ordered at no extra charge
• 1 X – Harness
• HAR000028 – Harness RS232 2M cable – DB9 to RJ-45
• 1 X – Quick Start Guide
• 1 X – China RoHS statement
If anything is damaged or missing, contact your customer representative immediately.
For customer support go to:
www.mellanox.com
=>Support => Customer Support Portal Login
3.6.1
Installing the Switch in the Rack
Tools and Customer Supplied Parts:
• Phillips Screwdrivers #1 and #2 • Grounding screw
• ESD strap • Grounding wire sufficient to reach a valid ground.
• ESD mat
For racks from 60cm to 80cm deep either use the standard depth switches with the long rail kit or the short switches with the long rail kit.
Parts included in the rail kit:
• 2 rails
• 2 rail slides
• 2 switch slides
• 16 recessed flat head screws You will have extras!
• 10 caged nuts
• 10 pan head screws M6
28 Mellanox Technologies
SwitchX 36-Port QSFP 40Gb/s Ethernet System Hardware User Manual
Figure 16: Rack Rail Kit Parts
Switch slide x2
Rail x2
Rail slide x2
Rev 1.3
1. Place the ESD mat on the floor where you will be working and put on the ESD strap. Make sure the ESD strap is touching your skin and that the other end is connected to a verified ground.
2. Choose which side of the switch you want even with the rack vertical support. Either the side with the power supply units or the side with the QSFP connectors can be even with one of the vertical rack supports.
Mellanox Technologies 29
Rev 1.3
Basic Operation and Installation
Figure 17: Placement of Switch in Rack
Doors
Connector side
Cable with recommended bending radius
19" (482.6mm)
Switch
Insufficient room for recommended bending radius
Spine side
Doors
Things to consider before choosing where to mount the rails and rail slides.
The distance between the rack and the door can be as little as 4 cm on one side of the rack and as much as 18 cm on the other side of the rack. Keep in mind that there can be as many as 36 cables connected to the switch.
• Do you want the connector side recessed in the rack to allow for a larger cable bending radius? It is possible to recess the connector side by 5cm by optional placement of the switch rails. See Figure 18,“Mounting Options”.
• Will the connector side be recessed past other equipment in the rack and will this be problematic?
• The installation kit allows for a 2” recess of the switch past the vertical support.
30 Mellanox Technologies
SwitchX 36-Port QSFP 40Gb/s Ethernet System Hardware User Manual
Figure 18: Mounting Options
Rev 1.3
3. Decide which mounting option you want to use.
To use the rail kit to transfer the power cord from the connector side to the power side go now to “Transferring the Power Cord” on page 54.
4. Screw the switch slides onto the switch. Use 5 flat head screws for short switches and 7 screws for standard depth switches, to connect each switch slide.
Figure 19: Screwing on the Rail
5 screws per side are needed for the short switch
7 screws per side are needed for the standard switch
There are 16 screws in the kit; you will have left over screws.
Mellanox Technologies 31
Rev 1.3
Basic Operation and Installation
Figure 20: Inserting the Caged Nuts
Side you will slide the switch into
Second side
5. Clip 6 caged nuts into the holes in the rack on the side of the rack you will be sliding the switch into. Check that both sides of the switch, power side and connector side, are at the same level in the rack.
6. Clip 4 more caged nuts into the holes on the opposite side of the rack. Check that both sides of the switch, left and right, are the same level in the rack.
7. Slide the rail into the rail slide.
8. Using two of the bolts for each corner install the rails and rail slides in the rack. Do not tighten the bolts yet.
Figure 21: Slide the Rail into the Rail Slide
32 Mellanox Technologies
This side of the rail kit goes on the side of the rack you will slide the switch into. This is the same side of the switch that will be next to the vertical support.
advertisement
Related manuals
advertisement
Table of contents
- 5 List of Figures
- 7 List of Tables
- 8 Revision History
- 9 About this Manual
- 9 Intended Audience
- 9 Related Documentation
- 9 Conventions
- 10 Abreviations
- 10 Mellanox Part Numbering Legend
- 11 Overview
- 12 1.1 Features
- 12 1.1.1 Full Feature List
- 12 1.2 Serial Number and Product Version Information
- 14 40 Gb/s Ethernet
- 15 Basic Operation and Installation
- 15 3.1 Switch Platform Hardware Overview
- 15 3.1.1 Status LEDs
- 20 3.1.2 Reset Button
- 22 3.2 Air Flow
- 22 3.3 QSFP Cable Power Budget Classification
- 23 3.4 Interfaces
- 23 3.4.1 Port Connector Interfaces
- 23 3.4.2 Management and Firmware Updating Interfaces
- 24 3.5 Switch Platform Installation and Operation
- 25 3.5.1 Installation Safety Warnings
- 27 3.5.2 Mechanical Installation
- 28 3.6 Package Contents and Installation
- 28 3.6.1 Installing the Switch in the Rack
- 33 3.7 Grounding the Switch
- 33 3.8 Power Connections and Initial Power On
- 35 3.9 Extracting and Inserting the Power Supply Unit
- 36 3.10 Supported Approved Cables
- 36 3.11 Splitting the Data Stream Using Breakout (Fanout) Cables
- 39 3.12 Cable Installation
- 40 3.13 Extracting and Inserting the Fan Unit
- 41 3.14 Switch Shut Down Procedure
- 42 3.15 Disassembly of the Switch from the Rack
- 42 3.16 Disposal
- 42 3.17 Resetting the Switch
- 44 Management and Tools Overview
- 44 4.1 Chassis Management Using the MLNX-OS™ Software
- 44 4.2 Configuring the Switch for the First Time
- 45 4.2.1 Starting a Remote Connection to the Switch
- 45 4.2.2 Upgrading Software
- 46 Troubleshooting
- 49 Specification
- 51 Approved Cables
- 51 EMC Certifications
- 52 China CCC Warning Statement
- 54 Transferring the Power Cord
- 56 QSFP Interface
- 58 RJ-45 CONSOLE and Ethernet interfaces
- 59 Replacement Parts Ordering Numbers
- 60 Avertissements de sécurité d’installation (French)
- 64 Installation - Sicherheitshinweise (German)
- 68 Advertencias de seguridad para la instalación (Spanish)