advertisement
PLU Add & Change
1.
From the
PGM
mode PROGRAMMING MENU touch
PLU
to view the PLU program selection window.
2.
Touch
PLU ADD & CHANGE
to view the SELECT PLU screen.
3.
You can edit existing PLUs in one of two ways:
Touch a PLU key located on the MAIN SCREEN, or touch
PAGE UP
/
PAGE DOWN
until the appropriate Key Link where you wish to edit a PLU displays. (Note: Beginning at v3.00c you can touch a modifier key, the a PLU.)
Enter the PLU number and touch
OK
.
You can add new PLUs in one of two ways
:
New PLUs that are to be located the MAIN SCREEN or a Key Link must first be assigned to a key location in
S
mode. Once a new PLU is assigned to a screen, touch the key to add the PLU descriptor and options.
PLUs can be randomly added by entering a PLU number and touching
OK
, or by scanning an item if a scanner is connected.
SPS-2000 Program Manual v1.37 P Mode Programming
79
4.
After a PLU is selected, the PLU PROGRAMMING screen displays at the
PAGE #1
tab:
5.
Touch the
PAGE #2
tab and/or the
PRICES
tab to access the remaining PLU options.
PLU Option Definitions
DESCRIPTOR
This is the name of the saleable item, which will appear on receipts and reports.
STOCK LINK PLU #
PLUs can be set to reduce stock levels set at another PLU. Set the number of the PLU where stock is affected (by activity of this PLU) here. This capability has applications where multiple PLUs affect a single inventory item, for example cup counts for beverage items and where items are counted without regard to brand, such as cigarette packs.
MODIFIER QTY
This works in conjunction with the stock link PLU flag determining how many units are to be reduced from the main stock item. The field consists of two decimal places for example 50 would result in 0.50 being reduced from the stock of the item program within the stock link PLU field.
GROUP LINK #1
This field is used to provide the first type of sales analysis by category i.e. Beer, Lagers.
Note
: at version
2.01m or later, you can touch this field and select the group link from a list.
PLU STATUS GROUP LINK#
This is the programming for the status group link. Providing an en-masse program procedure for common system flags
Note
: at version 2.01m or later, you can touch this field and select the PLU Status Group link from a list.
PIECE COUNT
Enter a value in this field if you wish to use Product Mix and Product Projection reporting. The number of units entered here will be reflected in product mix reporting.
80
P Mode Programming SPS-2000 Program Manual v1.37
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 9 SAM4s SPS-2000 Overview
- 9 Hardware
- 9 Software
- 9 Options
- 10 Unbox & Install MCR
- 10 Power Requirements
- 11 ECR Controls & Connections
- 11 Front Panel Angle Adjustment
- 12 Rear Display
- 12 SD Memory Card Slot
- 13 Connection Panel
- 14 Default Screen Layout
- 14 Screen Saver
- 15 Keylinks
- 16 Custom Screen Layouts
- 17 Passwords
- 17 Password Notes
- 17 Initialize
- 18 Memory All Clear
- 19 Overview
- 19 Important: Updating Existing Installations
- 20 Required Support Resources
- 21 SPS-2000 Program Components
- 22 Installing Software Using the TFTP Server Method
- 22 A. Download SPS-2000 Software Files
- 23 B. Set TCP/IP Protocol Options
- 25 C. Install and Start the TFTP Server
- 27 D. Install the Updated Software
- 29 E. Verify Software Version
- 32 Application Upgrade from SD/USB Card
- 34 Bootloader Upgrade from SD Card
- 35 O/S Upgrade from SD Card
- 36 Capturing SPS-2000 Screens
- 36 Equipment Required
- 36 Screen Capture Procedure
- 37 Image Downloads
- 37 Tips for Getting Images Ready
- 38 Image Download Using SD Memory Card
- 39 Screen Saver Logo
- 40 Save/Load End User Programs Using SD Memory Card
- 40 Save End User Program
- 40 Restore End User Program
- 41 Save Reports
- 41 Restore Reports
- 43 S- Mode Programming Screen
- 44 Self Tests
- 45 Memory Clearing
- 45 Memory Clear Options
- 47 Memory Allocation
- 47 Memory Allocation – Definitions
- 51 Key Relocation (V2.xxx)
- 53 Key Relocation (V3.0 and later)
- 53 The PGM Tab
- 53 The Design Tab
- 54 The List Tab
- 55 The Select Screen Tab
- 56 Function Key Code List
- 57 Function Key Definitions
- 66 System Options
- 66 S-Mode System Options – Definitions
- 69 Printer Driver Selections
- 69 Printer Driver - Definitions
- 70 Define Port
- 70 Define Port - Definitions
- 72 S-Mode Program Scan Printing
- 72 S-Mode Program Scans - Definitions
- 73 Password Notes
- 74 Load Default Messages
- 74 Check Unlock/Clerk Unlock
- 75 SRAM Backup
- 75 Save End User Program
- 75 Restore End User Program
- 76 Save Reports
- 76 Restore Reports
- 77 FTP Transmission
- 79 P-Mode Programming Menu
- 81 PLU Add & Change
- 84 PLU Delete
- 85 PLU Status Group
- 89 PLU Stock
- 90 PLU Minimum Stock
- 90 Non-PLU Code
- 91 Age Verification
- 92 PLU Quick Registration
- 99 PLU Integrity Check
- 100 PLU Group
- 101 Function Key
- 102 Function Key Program Summary
- 106 Function Key Programming Notes
- 110 System Options