Device Configuration Programming

Use the following procedure to select a device configuration programming:

Procedure

1.

In the SETTING window, select “11 DEVICE CONFIG.”

• The DEVICE CONFIG window will appear.

2.

Select any option from the following options list:

1 KEYBOARD

2 DISPLAY

3 PRINTER

4 RS PORT

5 ONLINE

6 SCANNER

Keyboard

Display

Printer

RS port

Online

Scanner

The following illustration shows those options included in this programming group.

11 DEVICE CONFIG 1 KEYBOARD

2 DISPLAY

3 PRINTER

4 RS PORT

5 ONLINE

6 SCANNER l

See “Keyboard” on page 109.

l

See “Display” on page 109.

l

See “Printer” on page 109.

l See "RS Port"on page 109.

l

See “Online” on page 110.

l See "Scanner"on page 110.

108

Keyboard

Procedure

Display

Procedure

Procedure

Printer

RS Port

Procedure

Program each item as follows:

• BUFFERING (Use the selective entry)

YES: Enables the buffering keyboard.

NO: Disables the buffering keyboard.

• TOUCH SOUND (Use the selective entry)

YES: Set to sound

NO: Not to sound

Program each item as follows:

• POWER SAVE (Use the numeric entry)

Time of the power save (2 digits: 0,1 to 99 minutes

0:100minutes)

• P. SAVE AT TM (Use the selective entry)

Power saving during time display:

YES: Enables power saving during time display

NO: Disables power saving during time display

Program each item as follows:

• DENSITY (Use the numeric entry)

Select a density level (2 digits: 00 to 99)

00: 89% for standard

50: 100% for standard

99: 111% for standard

Program each item as follows:

• USE (Use the selective entry)

ONLINE: RS port is used for on-line.

SCANNER: RS port is used for scanner.

109

Online

Procedure

The screen continues.

Program each item as follows:

• TERMINAL No. (Use the numeric entry)

Terminal number (6 digits: 0 to 999999).

• CI SIGNAL (Use the selective entry)

Sensing of the CI signal

NON: Disables sensing of the CI signal

SENSING: Enables sensing of the CI signal

• LINE FORM (Use the selective entry)

Programming of the modem control

FULL: Full duplex system

HALF: Half duplex system

• BAUD RATE (Use the selective entry)

Transmission data rate

38400 bps 19200 bps

9600 bps 4800 bps

• START CODE (Use the numeric entry)

Start code (3 digits: 0 to 127)

• END CODE (Use the numeric entry)

End code (3 digits: 0 to 127)

• TIME OUT (Use the numeric entry)

Programming of the time-out time (3 digits: 1 to 255 sec.)

Scanner

Procedure Program each item as follows:

• TYPE (Use the selective entry)

Selection of the scanner type

RS-CS CONTROL

RS-CD CONTROL

• BAUD RATE (Use the selective entry)

Transmission data rate

19200 bps 9600 bps 4800 bps

• DATA BIT (Use the selective entry)

Selection of the data bit

7 bits 8 bits

• PARITY (Use the selective entry)

Selection of the parity bit

NON ODD EVEN

• STOP BIT (Use the selective entry)

Selection of the stop bit

1 bit 2 bits

• ITF14 (Use the selective entry)

W LENGTH: With length

W/O LENGTH: Without length

110