Circulation Pump Modes. Balboa Water Group Revolution System 042412, Revolution 042412
Add to My manuals74 Pages
advertisement
READY RANGE FLTR1
HEAT T
Transforming the Control of Hot Tubs
Revolution
Circulation Pump Modes
If the system is equipped with a circ pump, it may be configured to work in one of three different ways: t The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
t t
The circ pump stays on continuously, regardless of water temperature.
A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when another pump is on.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during filtration. On circ systems, the ozone will run with the circ pump.
The system is factory-programmed with one filter cycle that will run in the evening (assuming the time-of-day is properly set) when energy rates are often lower. The filter time and duration are programmable. A second filter cycle can be enabled as needed.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefly to purge its plumbing to maintain good water quality.
40
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
advertisement
Related manuals
advertisement
Table of contents
- 9 Revolution Features
- 10 Revolution Specifications
- 11 Revolution Components
- 12 System Dimensions
- 14 Menus & Panel Operation
- 14 TP Panel Series
- 15 Panel Navigation
- 15 Warm/Cool Temperature Buttons
- 15 Light Button
- 16 Main Menu -- Revolution TP Series Control Panels
- 17 Temperature Adjustment
- 18 Dual Temperature Ranges
- 19 Setting a High Temperature Range
- 20 Setting a Low Temperature Range
- 22 Spa Light
- 23 Mode -- Ready and Rest
- 25 Choosing between Ready and Rest Mode
- 27 HOLD (Standby)
- 28 Drain Mode (if available)
- 29 LOCK (Restricting Panel Operation)
- 31 UNLK (Unlock, Allowing Panel Operation)
- 33 Setting the 24 Hour Clock
- 35 Temperature Display (F/C)
- 38 Pumps, Operation
- 40 Circulation Pump Modes
- 40 Filtration and Ozone
- 41 Freeze Protection
- 41 Clean-up Cycle (optional)
- 42 System Default Operation Settings
- 42 Pumps
- 43 Adjusting Filtration
- 44 Adjusting Filtration Time for F
- 49 Filter Cycle 2: Optional Filtration
- 56 Continuous Filtration (24 Hour Filtration)
- 61 Reminder Messages
- 62 Suppressing Reminders
- 65 CHEK PH
- 65 CHEK CHEM
- 65 CLN FLTR
- 66 TEST GFCI
- 66 CHNG WATR
- 66 CLN COVR
- 67 TRT WOOD
- 67 CHNG FLTR
- 67 CHNG CART
- 68 Glossary