ERA770A Eng Instr Man

ERA770A Eng Instr Man

NOTE

• The POS terminal can be programmed with up to nine tare tables and allows different tares to be assigned to them.

• When the

SCALE

key is pressed, the net weight is automatically read from the connected scale (option) and appears in the POS terminal display.

• When the PLU is programmed for “Compulsory scale entry,” it is not necessary to press the

• To issue a receipt which shows only a tare weight, press

OPEN

TARE

SCALE

, enter a tare weight, then press

key.

SCALE

and

CA/AT

.

Special Entries for PLUs

Mix-and-match function

This function is convenient for matching several PLU items and selling them in a lump (e.g. bundle sale, multi-packed sale, etc.). The base q’ty and unit price are assigned to a mix-and-match table. All items that are programmed into the same table are treated as if they belong to one group.

Link PLU entries

Operation is the same as that for normal PLU entries. When a link PLU is entered, the linked PLU’s amount is included and the linked PLU’s label is printed automatically. Only the 1st-ranking PLU is affected by the tax shift keys ( ranking PLU.

TAX1

SHIFT

,

TAX2

SHIFT

,

TAX3

SHIFT

and

TAX4

SHIFT

keys). The percent calculation is ellgible only for the amount of the 1st-

Combo meal entries

Operation is the same as that for normal PLU entries.

When a combo meal is entered with the Combo key, the labels of those PLUs linked to the Combo key are printed automatically. The sum of all adjusted prices (of those PLUs linked to the Combo key) becomes the

“combo meal” price that is registered.

NOTE

When combo meal is registered, q’ty totalizer of the combo key and amount totalizer of each

PLU are updated.

25

26

PLU level shift (for direct PLUs)

This shift can add to the number of direct PLUs on your POS terminal without adding additional direct PLU keys. You can use direct PLUs in ten levels by utilizing the PLU level shift keys

LEVEL

1

thru

LEVEL

10

.

Level key shifts the PLU level from the other nine to the required level. (The normal level is the level 1.)

You must program your machine in the PGM mode to select one of the two PLU level shift modes — automatic return mode* or lock shift mode** — and decide whether to allow PLU level shift in both the REG and MGR modes or in the MGR mode only.

* The automatic return mode automatically shifts the PLU level back to the level programmed after pressing a direct PLU key or finalizing each transaction.

** The lock shift mode holds the current PLU level until a PLU level shift key is pressed.

Automatic return mode (for PLU levels)

If your terminal has been programmed for PLU level in the automatic return mode, press a desired PLU level shift key before a numeric entry.

(Returning every item entry)

LEVEL

1

Numeric entry

Direct PLU Level programmed

LEVEL

10

(Returning every transaction)

LEVEL

1

Numeric entry

Direct PLU (Finalization)

LEVEL

10

NOTE

When you use the FF method, you need not press the

@

FOR key on numeric entry.

Lock shift mode (for PLU levels)

If your terminal has been programmed for PLU level in the lock shift mode, press a desired PLU level shift key before a numeric entry.

LEVEL

1

Numeric entry

Direct PLU Stay in the current level

LEVEL

10

NOTE

• When you use the FF method, you need not press the

@

FOR

key for multiplication entries.

PLU price level shift

NOTE

To use this function, please contact your authorized SHARP dealer.

Five different price levels can be programmed for each PLU.

The price levels can be changed for PLU registrations.

These keys have the following functions:

SHIFT

1

SHIFT

2

: Shifts the PLU price level from level 2, 3, 4, or 5 to level 1 (base level).

: Shifts the PLU price level from level 1, 3, 4, or 5 to level 2. When you press this key, the price level

SHIFT

3 shift indicator will turn to “P2.”

: Shifts the PLU price level from level 1, 2, 4, or 5 to level 3. When you press this key, the price level

SHIFT

4 shift indicator will turn to “P3.”

: Shifts the PLU price level from level 1, 2, 3 or 5 to level 4. When you press this key, the price level

SHIFT

5 shift indicator will turn to “P4.”

: Shifts the PLU price level from level 1, 2, 3 or 4 to level 5. When you press this key, the price level shift indicator will turn to “P5.”

* The automatic return mode automatically shifts the PLU price level back to level 1 after a PLU entry. You can select whether the PLU price level should return each time you enter one item or each time you finalize one transaction.

** The lock shift mode holds the current PLU price level until pressing a price level shift key.

Automatic return mode (for price shifts)

If your terminal has been programmed for PLU price level in the automatic return mode, press a desired price level shift key before a numeric entry.

(each item)

SHIFT

1

SHIFT

5

(each transaction)

SHIFT

2

Numeric entry

PLU no.

Direct PLU

PLU/

SUB

SHIFT

5

Numeric entry

PLU no.

Direct PLU

PLU/

SUB

NOTE

When you use the FF method, you need not press the

@

FOR

key on numeric entry.

[Payment]

Return to price level 1

Lock shift mode (for price shifts)

If your terminal has been programmed for PLU price level in the lock shift mode, press a desired price level shift key before a numeric entry.

To shift the price level of another PLU

SHIFT

1

Numeric entry

SHIFT

5

PLU no.

Direct PLU

PLU/

SUB

Stay in the current price level

NOTE

If you select the automatic return mode, it is not necessary to use the

SHIFT

1

key on the keyboard. If you select the lock shift mode, it is necessary to use the

SHIFT

1

When you use the FF method, you need not press the

key.

@

FOR

key on numeric entry.

27

Condiment entries

Your terminal may be programmed for prompting condiment and preparatory instructions for a menu-item

PLU.

Example:

When you enter a menu-item PLU, a prompting message such as “HOWCOOK?” and a list of the “Following

PLUs” will appear. You must specify one of the “Following PLUs” such as “without mustard” to meet a special order of the guest. In an example of the condiment table shown below, it is assumed that the condiment table no.1 is assigned to PLU number 21 (programmed text “STEAK”) and table no. 4 is assigned to table no. 1 as the next table no. When you enter the PLU number 21, the message “HOWCOOK?” will appear to prompt you to specify one of “RARE,” “MED.RARE,” and “WELLDONE.” If the guest chooses

“RARE,” select it from the list. Then the next message “POTATO?” will appear to prompt you to specify one of “P.CHIPS,” “MASHED.P,” and “BAKED.P.” If the guest chooses mashed potato, select it. Then press the

CA/AT

key to end this entry.

Here is an example of how to perform a condiment entry when your condiment table is as shown below.

Table number

1

4

PLU numbers for condiment entry (programmed text, price)

22 23 25 27

(HOWCOOK? 0.00)

31

(POTATO? 0.00)

(RARE 0.00)

33

(P. CHIPS 0.60)

(MED.RARE 0.00) (WELLDONE 0.00)

37

(MASHED.P 0.60)

38

(BAKED.P 0.50)

Next table no.

4

––––––––

Menu-item

PLUs

First PLU Following PLUs

NOTE

Your POS terminal will continue to operate for the condiment entry until you finish the entire condiment entry programmed for the PLU. During the condiment entry, if you enter a normal PLU, which is not in the condiment table, an error message will appear.

When REPEAT TIMES of the condiment table is programmed for example, of 2 thru 9, its table shows repeatedly until accomplishment of a programmed times, then the next table will show.

When the

C

NEXT

key is pressed, the entry skips to the next table which is programmed.

When the

CANCEL

key is pressed, its condiment entry is canceled in the programmed mode (REG/MGR or

MGR).

When you enter a PLU priced at “0.00,” only the text will be printed on the receipt.

No multiplication entry is possible for condiment entries.

No refund entry is possible for condiment entries. When you perform a refund entry with a menu-item

PLU, the “First PLU” and the “Following PLUs” assigned to the menu-item PLU are automatically registered as a refund entry.

You may omit the compulsory condiment entry by pressing the

CANCEL

key. (Please consult your dealer for more details.)

The cursor void entry is allowed for those PLUs that are entered as condiments (menu and condiment).

Repeat round entries

This function can be used for reorder entries for PLU items (single PLU item and condiment PLU) simply by depressing the

RP

ROUND

key. To use this function, PLU must be preset as “yes” for repeat entries.

At the first depression of the

RP

ROUND

key, those items that were previously registered in a transaction are subjected for reordered items, and at the second depression of the

RP

ROUND

key, those items that are registered after previous depression of the

RP

ROUND

including the items of first reordered items.

28

NOTE

When the

VOID

key is pressed just after the depression of the entries are voided.