10.2 Keypad. Ahlborn ALMEMO 2790, MA2790BTFV 32 Pages
advertisement
Display
Special operating states and faults
Segment test for display: This is performed automatically each time the device is switched on.
Supply voltage: (s. 11.1) Display after segment test
Below 3.6 V: LOBAT arrow lights up
Wireless link established:
Measuring with wireless transmission:
Programming function selected:
CONNECT arrow lights up
START arrow lights up
FCT arrow lights up
Checksum error during device calibration:
CALEr
Non-connected sensors, deactivated measuring points:
Measuring range / function not permitted:
-----
Err
Sensor breakage:
NiCr
Abbreviation flashes
Measuring range undershot,
CJ or CJ breakage (cold junction)
Value range overshot (>65000):
Measuring range overshot:
Measuring range undershot:
CJ
flashes
65OOO
flashes
Maximum value flashes
Minimum value flashes
10.2 Keypad
To operate the device a keypad with seven keys is provided.
Operation via the keypad is disabled in sleep mode and in some levels of device locking. (see 13.2).
ALMEMO ® 2790 17
advertisement
Related manuals
advertisement
Table of contents
- 2 1. OPERATING CONTROLS
- 5 3. GENERAL
- 5 3.1 Warranty
- 6 3.2 Standard delivery
- 6 3.3 Waste disposal
- 7 4. SAFETY INSTRUCTIONS
- 8 4.1 Special notes on use
- 8 4.2 Handling batteries / rechargeable batteries correctly
- 9 5. INTRODUCTION
- 9 5.1 Functions
- 10 5.1.1 Sensor programming
- 10 5.1.2 Process control
- 11 6. PUTTING INTO SERVICE
- 11 7. POWER SUPPLY
- 11 7.1 Operation using rechargeable batteries / batteries
- 11 7.1.1 Operation using rechargeable batteries
- 12 7.1.2 Operation using standard batteries
- 12 7.1.3 Supply voltage monitoring
- 12 7.2 Mains operation
- 13 7.3 External DC voltage supply
- 13 7.4 Sensor supply
- 13 7.5 Switching ON / OFF, reinitialization
- 13 7.6 Data buffering
- 13 8. PAIRING
- 14 9. CONNECTING SENSORS
- 14 9.1 Sensors
- 14 9.2 Measuring inputs und additional channels
- 15 9.3 Potential separation
- 16 10. DISPLAY AND KEYPAD
- 16 10.1 Display
- 17 10.2 Keypad
- 18 11. MEASURING OPERATIONS
- 18 11.1 Measured value
- 18 11.1.1 Selecting a measuring point
- 20 11.1.2 Measuring quantities and ranges
- 22 11.1.3 Dual display
- 22 11.2 Peak values memory
- 22 12. INTERFACE
- 22 13. DEVICE CONFIGURATION
- 23 13.1 Cycle
- 24 13.2 Device locking
- 24 13.3 Atmospheric pressure compensation
- 25 14. WIRELESS TRANSMISSION TO DATA LOGGER
- 25 15. TROUBLE-SHOOTING
- 27 16. ANNEX
- 27 16.1 Technical data
- 28 16.2 Product overview
- 29 16.3 Index
- 32 16.4 Your contact partners