11.1.2 Measuring quantities and ranges. Ahlborn ALMEMO 2790, MA2790BTFV 32 Pages
11.1.2 Measuring quantities and ranges. Ahlborn ALMEMO 2790, MA2790BTFV
advertisement
11. Measuring operations
Pt100-1
Pt100-2
Ni100
NiCr-Ni (K)
NiCroSil-NiSil (N)
Fe-CuNi (L)
Fe-CuNi (J)
Cu-CuNi (U)
Cu-CuNi (T)
PtRh10-Pt (S)
PtRh13-Pt (R)
PtRh30-PtRh6 (B)
Au-FeCr
Ntc type N
Millivolt
Millivolt 1
Millivolt 2
Volts
Difference - millivolt
Difference - millivolt 1
Difference - millivolt 2
Difference - volt
Sensor voltage
Milliampere
Percent (4 to 20 mA)
Ohms
Frequency
Pulses
Digital input
Digital interface
Snap-on head
Normal 20
Snap-on head
Normal 40
Snap-on head
Micro 20
Snap-on head
Micro 40
Macro
Water micro
11.1.2 Measuring quantities and ranges
Whenever there is a channel switchover or sensor breakage the measuring range abbreviation appears in the display. The following table lists all the measuring ranges possible.
Sensors Sensor / plug
FP Axxx
FP Axxx
ZA 9030-FS3
FT Axxx
ZA 9020-FSN
ZA 9021-FSL
ZA 9021-FSJ
ZA 9000-FSU
ZA 9021-FST
FS Axxx
ZA 9000-FSR
ZA 9000-FSB
Measuring range Unit Abbreviation
-200.0... +850.0
°C P104
-200.00...+400.00
°C P204
-60.0... +240.0
°C N104
-200.0...+1370.0
°C NiCr
-200.0...+1300.0
°C NiSi
-200.0... +900.0
°C FECO
-200.0...+1000.0
°C IrCo
-200.0... +600.0
°C CUCO
-200.0... +400.0
°C CoCo
0.0...+1760.0
°C Pt10
0.0...+1760.0
°C Pt13
+400.0...+1800.0
°C EL18
-270.0... +60.0
°C AUFE
-50.00...+125.00
°C
ZA 9000-FSA
FN Axxx
ZA 9000-FS0
ZA 9000-FS1
ZA 9000-FS2
ZA 9000-FS3
Ntc
-10.000...+55.000
mV U 55
-26.000...+26.000
mV U 26
-260.00...+260.00
mV U260
-2.0000...+2.6000
V U2 .
60
ZA 9000-FS0D -10.000...+55.000
mV d 55
ZA 9000-FS1D -26.000...+26.000
mV d 26
ZA 9000-FS2D -260.00...+260.00
mV d260
ZA 9000-FS3D -2.0000...+2.6000
any 0.00...20.00
ZA 9601-FS1 -26.000...+26.000
mA I032
ZA 9601-FS2 0.00... 100.00
V d2 .
60
V UbAt
ZA 9003-FS
ZA 9909-AK1
ZA 9909-AK2
ZA 9000-EK2
ZA 9919-AKxx
FV A915-S120
0.0... 500.0
Ohn
0... 32000 Hz FrEq
0... 65000
% P420
W
0.0... 100.0
PULS
% Inp
-65000... +65000 diGi
0.30... 20.00
m/s S120
FV A915-S140
FV A915-S220
FV A915-S240
FV A915-MA1
FV A915-WM1
0.40... 40.00
m/s S140
0.50... 20.00
m/s S220
0.60... 40.00
m/s S240
0.10... 20.00
m/s L420
0.00... 5.00
m/s L605
20 ALMEMO ® 2790
Measured value
Sensors Sensor / plug
Dynamic pressure, 40 m/s with TC and PC
Dynamic pressure, 90 m/s with TC and PC
FD A612-M1
FD A612-M6
Rel. atm. humidity, capacitive FH A646
Rel. atm. humidity, cap. with TC FH A646-C
Rel. atm. humidity, cap. with TC FH A646-R
Mixture ratio, capacitive with PC FH A646
Dew-point temp., capacitive
Partial vapor pressure, cap.
FH A646
FH A646
Enthalpy, capacitive with PC
Temperature, wet
FH A646
FN A846
RH, psychrometric with PC FN A846
Mixture, psychrometric with PC FN A846
TD, psychrometric with PC FN A846
Partial vapor pressure, psychrometric with PC
FN A846
Enthalpy, psychrometric with PC FN A846
Conductivity probe with TC FY A641-LF
CO
2
sensor FY A600-CO2
O
2
saturation with TC and PC FY A640-O2
O2 concentration with TC
Temperature, digital * (B68)
Humidity, digital * (B69)
FY A640-O2
FH0D46-2
FH0D46-2
Function channels
Differential channels Mb1 - Mb2 any
Maximum value of channel Mb1 any
Minimum value of channel Mb1 any
Av. val. over time, M(t) of Mb1 any
Average value M(n) Mb2 to Mb1 any
Sum S(n) Mb2 to Mb1
Total pulses S(t) of Mb1 any
ZA 9909-AK2
Pulses / print cycle of Mb1
Alarm value of channel Mb1
ZA 9909-AK2 any
Measured value of Mb1
Cold junction temperature
Number of av. values of Mb1 any
Timer any any any
Atm. pressure ° (B86) see 13.3 any
Measuring range Unit Abbreviation
0.50... 40.00
m/s L840
1.00... 90.00
m/s L890
0.0... 100.0
%H °orH
0.0... 100.0
%H HcrH
0.0... 100.0
%H H rH
0.0 ... 500.0
g/k H AH
-25.0... 100.0
°C H dt
0.0 ...1050.0
mb H UP
0.0 ... 400.0
kJ H En
-30.00 ... +125.00
°C P Ht
0.0 ... 100.0
%H P RH
0.0 ... 500.0
g/k P AH
-25.0 ... +100.0
°C P dt
0.0 ...1050.0
mb P UP
0.0 ... 400.0
kJ P En
0.0 ... 20.000
mS
0.0 ... 2.500
0 ... 260
%
LF
CO2
% O2-S
0 ... 40.0
mg O2-C
-20.00 ... +80.00
°C d °C
0.0 ... 100.0
%H d %H
0... 65000
0... 65000 diFF
Hi
Lo
A[t]
A[n]
S[n]
S[t]
S[P]
Alrn
MESS
°C CJ n(t) s tinE
300...1100
mb AP
TC=Temperature compensation, PC=Atmospheric pressure compensation,
* Only with option 2790-RH, ° Only with option AP
ALMEMO ® 2790 21
advertisement
Related manuals
advertisement
Table of contents
- 2 1. OPERATING CONTROLS
- 5 3. GENERAL
- 5 3.1 Warranty
- 6 3.2 Standard delivery
- 6 3.3 Waste disposal
- 7 4. SAFETY INSTRUCTIONS
- 8 4.1 Special notes on use
- 8 4.2 Handling batteries / rechargeable batteries correctly
- 9 5. INTRODUCTION
- 9 5.1 Functions
- 10 5.1.1 Sensor programming
- 10 5.1.2 Process control
- 11 6. PUTTING INTO SERVICE
- 11 7. POWER SUPPLY
- 11 7.1 Operation using rechargeable batteries / batteries
- 11 7.1.1 Operation using rechargeable batteries
- 12 7.1.2 Operation using standard batteries
- 12 7.1.3 Supply voltage monitoring
- 12 7.2 Mains operation
- 13 7.3 External DC voltage supply
- 13 7.4 Sensor supply
- 13 7.5 Switching ON / OFF, reinitialization
- 13 7.6 Data buffering
- 13 8. PAIRING
- 14 9. CONNECTING SENSORS
- 14 9.1 Sensors
- 14 9.2 Measuring inputs und additional channels
- 15 9.3 Potential separation
- 16 10. DISPLAY AND KEYPAD
- 16 10.1 Display
- 17 10.2 Keypad
- 18 11. MEASURING OPERATIONS
- 18 11.1 Measured value
- 18 11.1.1 Selecting a measuring point
- 20 11.1.2 Measuring quantities and ranges
- 22 11.1.3 Dual display
- 22 11.2 Peak values memory
- 22 12. INTERFACE
- 22 13. DEVICE CONFIGURATION
- 23 13.1 Cycle
- 24 13.2 Device locking
- 24 13.3 Atmospheric pressure compensation
- 25 14. WIRELESS TRANSMISSION TO DATA LOGGER
- 25 15. TROUBLE-SHOOTING
- 27 16. ANNEX
- 27 16.1 Technical data
- 28 16.2 Product overview
- 29 16.3 Index
- 32 16.4 Your contact partners