Advertisement
Advertisement
Commissioning the STG R 06.07
2 Commissioning the STG
2.1
Included Components
The STG consists of several components which are listed individually on the delivery slip.
Ordered
Components
MOBY D hand-held terminal STG
MOBY E hand-held terminal STG
MOBY F hand-held terminal STG
MOBY I hand-held terminal STG
Order Number Pack List Pack Number
6GT2 603-0AA00 PSION Workabout mx
NiCd battery
6GT2 303-0AA00 PSION Workabout mx
A5E00016735
MOBY D read head 6GT2 603-1AA00
Memory card incl.
STG software and user’s manual
6GT2 303-1CA00
6GT2 094-0AB00
A5E00016735
6GT2 303-1AA00
6GT2 303-1CA00
MOBY E read head
Memory card incl.
STG software and user’s manual
NiCd battery
6GT2 403-0BA00 PSION Workabout mx
MOBY F read head
6GT2 094-0AB00
A5E00016735
6GT2 403-1BA00
6GT2 303-1CA00 Memory card incl.
STG software and user’s manual
NiCd battery
6GT2 003-0CA00 PSION Workabout mx
MOBY I read head
Memory card incl.
STG software and user’s manual
NiCd battery
6GT2 094-0AB00
A5E00016735
6GT2 003-1CA00
6GT2 303-1CA00
6GT2 094-0AB00
E-4
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418
R 06.07
Commissioning the STG
Ordered
Components
MOBY U hand-held terminal STG
Order Number Pack List Pack Number
6GT2 503-0AA00 PSION Workabout mx A5E00016735
MOBY U antenna 6GT2 503-1AA00
6GT2 303-1CA00 Memory card incl.
STG software and user’s manual
NiCd battery 6GT2 094-0AB00
2.2
Assembly
Perform the following steps in the order shown below.
S Install button cell. Button cell is located in a recess in the packaging of the
PSION Workabout.
S Insert batteries. The battery catch must point to the left.
S Insert the flash program memory with the STG application in the upper slot (A).
S Install read head, and screw down (MOBY D/E/F/I).
S Join antenna and PSION Workabout (MOBY U).
– Screw the PSION Workabout to the metal frame with 4 screws.
– Plug the submin D plug of the MOBY U antenna into the RS 232 interface of the PSION Workabout and screw down.
– Slide the PSION Workabout on the guide rail of the upper housing shell of the antenna until the lock snaps in.
Assembly is complete.
Note
After assembly, the hand-held terminal must be charged immediately so that the button cell is not discharged unnecessarily. For information on the lifespan of the button cell, see the included PSION documentation.
Charging is omitted if the PSION Workabout is configured with nonchargeable batteries instead of the standard storage batteries.
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418 E-5
Commissioning the STG R 06.07
2.3
Turning on the Device and Setting the
Operating Mode
Note
Before you turn on the device, insert the hand-held terminal in the charging device (MOBY D/E/F/I) or connect to the power pack
(6GT2 503-1DA00) (MOBY U) and allow it to charge for at least
14 hours.
After charging, the hand-held terminal is ready for use.
After the terminal is turned on, initial startup takes several seconds. The MOBY application then starts automatically, and a selection menu appears with the
MOBY applications. Select the MOBY application for the RF read/write head or the antenna which you want to use.
1) MOBY filehandler for MOBY I
The MDS data are accessed by file
2)-6)Normal MOBY service and test program for MOBY D/E/F/I/U. The MDS data are accessed by physical addres-
9) The operating system of the hand-held terminal is accessed with “Exit.”
V) Version indication in MOBY application menu (not shown in selection menu)
The device goes off automatically after no keys have been pressed for 5 minutes. When turned on again, the hand-held terminal continues with the same screen it was displaying before it was turned off manually or automatically.
E-6
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418
R 06.07
Commissioning the STG
2.4
MOBY Applications
If you use a different read head (MOBY D/E/F/I) or the MOBY U antenna with the hand-held terminal later on, you will have to change the MOBY application.
Exit the running application with the FILE/EXIT menu. The PSION start screen appears. Confirm this screen with ENTER. Then select the required MOBY application in the next screen which appears.
2.5
User Interface
Use of the STG programs MOBY D/E/F/I/U on the hand-held terminal is
Use of the Filehandler program for MOBY I is described in chapter 5.
All functions of the MOBY programs can be called with the “Menu” key.
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418 E-7