Introduction. PARADOX ESPRIT 728 ULT, 738ULT

Add to My manuals
56 Pages

advertisement

Introduction. PARADOX ESPRIT 728 ULT, 738ULT | Manualzz

Part 1: Introduction

1.1

About This Manual

This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel features and programming. Please refer to the index for a complete list of this manual's contents.

Programming method used to program this feature

Section title Where the feature is programmed

Factory default

6.15

Report Zone Restore Options

Feature Select Programming

D

Address 088; Key [ BYP ]

Default: Zone Restore Codes Transmit on Bell Cut-Off

With the [ BYP ] key OFF, the report codes programmed at addresses 424 to 447 (see

Restore Codes on page 22) will only

transmit if the zone has returned to normal after bell cut-off (see Bell Cut-Off Time on page 34). With the

[ BYP ] key ON, the codes will transmit as soon as the zone returns to normal (zone closure).

Key [ BYP ] OFF: Report on Bell Cut-Off

Key [ BYP ] ON: Report on Zone Closure

[ ENTER ] + Installer code + [0] [8] [8] + [ BYP ] ON/OFF + [ ENTER ]

Section # Description of feature How to program Option

1.2

New Features

Feature

2-wire smoke detector

Serial or parallel wiring for ATZ connections (see page 27)

Master Code Lock (see page 11)

New Pager reporting options: Pager Delay, Pager Format Options and

Pager Report Event Options (page 21)

Closing Delinquency Timer and Time options (see page 34)

Auto Test Report Time Option (see page 23)

Restrict Arming on Battery Failure (see page 34) and Restrict Arming on

Tamper Trouble (see page 34)

New on-board green STATUS

LED (see page 11)

Timed Test Transmission (see page 24)

Bypassed zones reported to monitoring station on arming (see page 19)

728 Ultra

V4.10

9

9

9

728 Ultra

V4.20 - 4.40

9

9

9

9

9

9

9

9

9

9

9

9

738 Ultra

V4.0

9

9

9

9

738 Ultra V4.1

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

1.3

1.4

Main Features

• 4 zone inputs (8 zones with ATZ) + 2 keypad zones (728 Ultra)

• 8 zone inputs (16 zones with ATZ) + 2 keypad zones (738 Ultra)

• 2 partitions

• 49 user codes

• 256 event buffer

• 1 PGM output for 728 Ultra and 2 PGM outputs for 738 Ultra (50mA transistor output)

• 1.1A switching power supply

• 1 supervised auxiliary output (728 Ultra: 450mA, fuseless shutdown at 650mA; 738 Ultra: 500mA, fuseless shutdown at 700mA)

• 1 supervised bell output (fuseless shutdown at 3A)

• 1 supervised telephone line (supports Ademco Contact ID, Pager and slow report formats)

• CTR-21 approved dialer

• On-board connectors for backup battery and serial port

• Compatible with all Esprit keypads

Specifications

• AC power:

• Battery:

• Aux. power:

• Bell output:

16.5Vac transformer with minimum 20VA rating (40VA recommended), 50-60Hz

12Vdc, 4Ah/7Ah†

450mA, fuseless shutdown at 650mA for 728 Ultra; 500mA, fuseless shutdown at 700mA for 738 Ultra)†

1A (fuseless shutdown at 3A)

• PGM outputs: One 50mA PGM transistor output (728 Ultra); Two 50mA PGM transistor output (738 Ultra)

• Serial data output: (1200, 1, N) for use with accessory modules (not for use with UL systems)

† Please refer to Warnings on page 45 for UL Specifications. Specifications may change without prior notice.

Esprit 728 Ultra & 738 Ultra 1