Introduction. PARADOX ESPRIT 728 ULT, 738ULT 56 Pages
advertisement
Part 1: Introduction
1.1
About This Manual
This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel features and programming. Please refer to the index for a complete list of this manual's contents.
Programming method used to program this feature
Section title Where the feature is programmed
Factory default
6.15
Report Zone Restore Options
Feature Select Programming
D
Address 088; Key [ BYP ]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the [ BYP ] key OFF, the report codes programmed at addresses 424 to 447 (see
Restore Codes on page 22) will only
[ BYP ] key ON, the codes will transmit as soon as the zone returns to normal (zone closure).
Key [ BYP ] OFF: Report on Bell Cut-Off
Key [ BYP ] ON: Report on Zone Closure
[ ENTER ] + Installer code + [0] [8] [8] + [ BYP ] ON/OFF + [ ENTER ]
Section # Description of feature How to program Option
1.2
New Features
Feature
2-wire smoke detector
Serial or parallel wiring for ATZ connections (see page 27)
Master Code Lock (see page 11)
New Pager reporting options: Pager Delay, Pager Format Options and
Pager Report Event Options (page 21)
Closing Delinquency Timer and Time options (see page 34)
Auto Test Report Time Option (see page 23)
Restrict Arming on Battery Failure (see page 34) and Restrict Arming on
New on-board green STATUS
Timed Test Transmission (see page 24)
Bypassed zones reported to monitoring station on arming (see page 19)
728 Ultra
V4.10
9
9
9
728 Ultra
V4.20 - 4.40
9
9
9
9
9
9
9
9
9
9
9
9
738 Ultra
V4.0
9
9
9
9
738 Ultra V4.1
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
1.3
1.4
Main Features
• 4 zone inputs (8 zones with ATZ) + 2 keypad zones (728 Ultra)
• 8 zone inputs (16 zones with ATZ) + 2 keypad zones (738 Ultra)
• 2 partitions
• 49 user codes
• 256 event buffer
• 1 PGM output for 728 Ultra and 2 PGM outputs for 738 Ultra (50mA transistor output)
• 1.1A switching power supply
• 1 supervised auxiliary output (728 Ultra: 450mA, fuseless shutdown at 650mA; 738 Ultra: 500mA, fuseless shutdown at 700mA)
• 1 supervised bell output (fuseless shutdown at 3A)
• 1 supervised telephone line (supports Ademco Contact ID, Pager and slow report formats)
• CTR-21 approved dialer
• On-board connectors for backup battery and serial port
• Compatible with all Esprit keypads
Specifications
• AC power:
• Battery:
• Aux. power:
• Bell output:
16.5Vac transformer with minimum 20VA rating (40VA recommended), 50-60Hz
12Vdc, 4Ah/7Ah†
450mA, fuseless shutdown at 650mA for 728 Ultra; 500mA, fuseless shutdown at 700mA for 738 Ultra)†
1A (fuseless shutdown at 3A)
• PGM outputs: One 50mA PGM transistor output (728 Ultra); Two 50mA PGM transistor output (738 Ultra)
• Serial data output: (1200, 1, N) for use with accessory modules (not for use with UL systems)
Esprit 728 Ultra & 738 Ultra 1
advertisement
Related manuals
advertisement
Table of contents
- 5 Introduction
- 5 About This Manual
- 5 New Features
- 5 Main Features
- 5 Specifications
- 6 Installation
- 6 Location and Mounting
- 6 Earth Ground
- 6 AC Power
- 6 Backup Battery
- 7 Auxiliary Power Terminals
- 7 Battery Test
- 7 Keypad Function Test
- 7 Telephone Line Connection
- 8 Bell/Siren Output
- 8 Alarm Relay Outputs (738 Ultra; Optional)
- 8 Programmable Outputs (PGMs)
- 8 Keypad and Keyswitch Connections
- 9 Keypad Zone Connections
- 10 Connecting an Anti-Tamper Switch on an LED Keypad
- 10 Single Zone Input Terminal Connections
- 10 N.C. Contacts, Without EOL Resistor
- 11 N.O. and N.C. Contacts, With EOL Resistor (UL/cUL)
- 11 Recognition
- 11 Wire Fault Recognition (UL/cUL)
- 11 Advanced Technology Zone (ATZ) Connections
- 12 N.C. Contacts, Without EOL Resistor, ATZ Series
- 13 Recognition, ATZ Series
- 13 Wire Fault Recognition (UL/cUL), ATZ Series
- 13 N.C. Contacts, With ATZ Parallel Wiring
- 14 Fire Circuit
- 14 4-Wire Smoke Detector Connections (Standard Installation)
- 14 4-Wire Smoke Detector Connections (UL/cUL Installation)
- 14 2-Wire Smoke Detector Connections
- 14 Serial Output Connector
- 15 Status LED
- 15 Access Codes
- 15 Installer Code
- 15 Master and User Codes
- 15 User/Access Code Length
- 15 Duress
- 15 Installer Lock
- 15 Master Code Lock
- 16 Programming Methods
- 16 Espload Software
- 16 Keypad
- 16 Hex Programming
- 17 Hex Streamlined Section Programming
- 17 Decimal Programming
- 17 Feature Select Programming
- 18 Panel Settings for Espload
- 18 Panel Answer Options
- 18 Panel Identifier
- 18 PC Password
- 19 Computer Telephone Number
- 19 Call Espload
- 19 Answer Espload
- 19 Cancel Communication
- 19 Call Back
- 19 Automatic Event Buffer Transmission
- 20 Event Reporting
- 21 Reporting Options
- 21 Reporting Disabled
- 21 Regular Reporting
- 21 Split Reporting
- 21 Double Reporting
- 22 Monitoring Station Telephone Number 1 (MSTN1)
- 22 Monitoring Station Telephone Number 2 (MSTN2)
- 23 System Account Codes
- 23 Communicator Formats
- 23 Ademco Contact ID (All Codes)
- 24 Ademco Contact ID (Programmable Codes)
- 25 Ademco Express
- 25 Pager Reporting Format
- 25 Standard Pulse Formats
- 25 Pager Delay
- 25 Pager Format Transmission Options
- 25 Pager Report Event Option
- 26 Reporting Event Codes
- 26 Arming Codes
- 26 Disarming Codes
- 26 Alarm Codes
- 26 Restore Codes
- 26 Zone Shutdown Codes
- 26 Tamper Codes
- 27 Trouble/Trouble Restore Codes
- 27 Special Codes
- 27 Auto Test Report
- 28 Timed Test Transmission (738 Ultra only)
- 28 Manual Test Report
- 28 Power Failure Report Delay
- 28 Recent Close Delay
- 28 Report Zone Restore Options
- 28 Report Code Disarming Options
- 29 Zone Definitions
- 31 Zone Speed
- 31 Advanced Technology Zoning (ATZ)
- 31 ATZ Parallel Wiring
- 31 Intellizones
- 31 Intellizone Time Delay
- 31 Silent Zones
- 32 24Hr and 4-Wire Smoke Detector Fire Zones
- 32 Enable/Disable Zone 4 (728 Ultra) or Zone 11 (738 Ultra)
- 32 2-Wire Smoke Detector Recognition (Input 3)
- 32 2-Wire Smoke Detector Reset
- 32 Instant Zones
- 32 Follow Zones
- 33 Entry Delay
- 33 Entry Time Delay
- 33 Partitioning
- 33 System A/Stay Zones