N.C. Contacts, Without EOL Resistor, ATZ Series. PARADOX ESPRIT 728 ULT, 738ULT 56 Pages
N.C. Contacts, Without EOL Resistor, ATZ Series. PARADOX ESPRIT 728 ULT, 738ULT
Add to My manuals56 Pages
advertisement
738 Ultra employ two ways of wiring ATZ connections: ATZ series connections and ATZ parallel connections. The control panel will recognize the installed devices as shown in Figure 15. The extra zones function exactly like any other zone displaying zone status on the keypad and sending separate alarm codes for each zone. For more information on programming the options
mentioned in the following sections, refer to see Zone Definitions on page 25.
Figure 15: Zone Recognition with ATZ Enabled
ATZ Series Wiring (728 Ultra)
Control Panel Terminals Control Panel Terminals
ATZ Parallel Wiring (728 Ultra)
Control Panel Terminals Control Panel Terminals
ATZ Series Wiring (738 Ultra)
Control Panel Terminals Control Panel Terminals
ATZ Parallel Wiring (738 Ultra)
Control Panel Terminals Control Panel Terminals
Control Panel Terminals Control Panel Terminals
Control Panel Terminals Control Panel Terminals
2.11.1
N.C. Contacts, Without EOL Resistor, ATZ Series
If your security installation does not require tamper or wire fault recognition, but you are using the ATZ feature, connect
contacts, as this will cause the system to remain in alarm. This setup will communicate the status of each device to the control panel (see Figure 15 on page 8) and display open zones on the keypad.
Figure 16: N.C. Contacts, without EOL Resistor
Address 088 , [
MEM
] = ON (EOL resistor disabled)
[0] = OFF
Tamper/Wire Fault disabled.
[ STAY ] = OFF
Address 090 , [7] = OFF (ATZ wiring in series)
[8] = ON (ATZ enabled)
8 Reference & Installation Manual
advertisement
Related manuals
advertisement
Table of contents
- 5 Introduction
- 5 About This Manual
- 5 New Features
- 5 Main Features
- 5 Specifications
- 6 Installation
- 6 Location and Mounting
- 6 Earth Ground
- 6 AC Power
- 6 Backup Battery
- 7 Auxiliary Power Terminals
- 7 Battery Test
- 7 Keypad Function Test
- 7 Telephone Line Connection
- 8 Bell/Siren Output
- 8 Alarm Relay Outputs (738 Ultra; Optional)
- 8 Programmable Outputs (PGMs)
- 8 Keypad and Keyswitch Connections
- 9 Keypad Zone Connections
- 10 Connecting an Anti-Tamper Switch on an LED Keypad
- 10 Single Zone Input Terminal Connections
- 10 N.C. Contacts, Without EOL Resistor
- 11 N.O. and N.C. Contacts, With EOL Resistor (UL/cUL)
- 11 Recognition
- 11 Wire Fault Recognition (UL/cUL)
- 11 Advanced Technology Zone (ATZ) Connections
- 12 N.C. Contacts, Without EOL Resistor, ATZ Series
- 13 Recognition, ATZ Series
- 13 Wire Fault Recognition (UL/cUL), ATZ Series
- 13 N.C. Contacts, With ATZ Parallel Wiring
- 14 Fire Circuit
- 14 4-Wire Smoke Detector Connections (Standard Installation)
- 14 4-Wire Smoke Detector Connections (UL/cUL Installation)
- 14 2-Wire Smoke Detector Connections
- 14 Serial Output Connector
- 15 Status LED
- 15 Access Codes
- 15 Installer Code
- 15 Master and User Codes
- 15 User/Access Code Length
- 15 Duress
- 15 Installer Lock
- 15 Master Code Lock
- 16 Programming Methods
- 16 Espload Software
- 16 Keypad
- 16 Hex Programming
- 17 Hex Streamlined Section Programming
- 17 Decimal Programming
- 17 Feature Select Programming
- 18 Panel Settings for Espload
- 18 Panel Answer Options
- 18 Panel Identifier
- 18 PC Password
- 19 Computer Telephone Number
- 19 Call Espload
- 19 Answer Espload
- 19 Cancel Communication
- 19 Call Back
- 19 Automatic Event Buffer Transmission
- 20 Event Reporting
- 21 Reporting Options
- 21 Reporting Disabled
- 21 Regular Reporting
- 21 Split Reporting
- 21 Double Reporting
- 22 Monitoring Station Telephone Number 1 (MSTN1)
- 22 Monitoring Station Telephone Number 2 (MSTN2)
- 23 System Account Codes
- 23 Communicator Formats
- 23 Ademco Contact ID (All Codes)
- 24 Ademco Contact ID (Programmable Codes)
- 25 Ademco Express
- 25 Pager Reporting Format
- 25 Standard Pulse Formats
- 25 Pager Delay
- 25 Pager Format Transmission Options
- 25 Pager Report Event Option
- 26 Reporting Event Codes
- 26 Arming Codes
- 26 Disarming Codes
- 26 Alarm Codes
- 26 Restore Codes
- 26 Zone Shutdown Codes
- 26 Tamper Codes
- 27 Trouble/Trouble Restore Codes
- 27 Special Codes
- 27 Auto Test Report
- 28 Timed Test Transmission (738 Ultra only)
- 28 Manual Test Report
- 28 Power Failure Report Delay
- 28 Recent Close Delay
- 28 Report Zone Restore Options
- 28 Report Code Disarming Options
- 29 Zone Definitions
- 31 Zone Speed
- 31 Advanced Technology Zoning (ATZ)
- 31 ATZ Parallel Wiring
- 31 Intellizones
- 31 Intellizone Time Delay
- 31 Silent Zones
- 32 24Hr and 4-Wire Smoke Detector Fire Zones
- 32 Enable/Disable Zone 4 (728 Ultra) or Zone 11 (738 Ultra)
- 32 2-Wire Smoke Detector Recognition (Input 3)
- 32 2-Wire Smoke Detector Reset
- 32 Instant Zones
- 32 Follow Zones
- 33 Entry Delay
- 33 Entry Time Delay
- 33 Partitioning
- 33 System A/Stay Zones