Part 4: Programming Methods
The 728 Ultra and 738 Ultra control panels can be programmed using either the keypad or the Espload Software (V3.0 or higher for 728
Ultra, and V3.4 or higher for 738 Ultra). We highly recommend programming the control panels using the Espload Software, as it simplifies the process and reduces the potential for data entry errors.
4.1
4.2
Espload Software
With the Espload Software (V3.0 or higher for 728 Ultra, and V3.4 or higher for 738 Ultra), you can program the 728 Ultra and 738
Ultra control panels remotely via modem or locally using an ADP-1 adapter. The advanced Espload software can execute fast uploads or downloads and provides many powerful features. These include a comprehensive monitoring mode to oversee all panel activity, a scheduler to initiate pre-programmed tasks at set intervals, and a batch mode to carry out pre-programmed tasks following a call from the control panel. Using Espload there is no limit to the number of account files or panel defaults created and you can assign thousands of programming combinations to the PGM outputs. Espload can also be converted to the language of your choice. Contact your local Paradox Distributor for your free copy of the Espload software.
Keypad
When programming, use the 728 Ultra & 738 Ultra System Programming Guide to keep track of which addresses were programmed and how. Before you begin programming the control panel, we recommend that you read Parts 5 through 11 of this manual in order to give you a good understanding of the control panel and its many features. When programming with the keypad, certain addresses are programmed using different methods. These methods are described in detail below. Each section in this manual will reference the appropriate programming method.
4.2.1
Hex Programming
Addresses 000 to 043 and 300 to 527 are programmed using the Hex Programming method. In this mode, you can enter any hex-digit from 0 to F where keys [1] to [9] represent digits 1 to 9 respectively; the other keys represent hex-
digits A to F as shown in Figure 23. To program using the Hex Programming method:
1. Press [ ENTER ] + Installer code. The [ ENTER ] key will flash indicating you are in programming mode (LED keypad only).
2. Enter the desired 3-digit address. The keypad will display the 2-digit data currently saved at this address as
3. Enter 2-digit data. After entering data you do not need to press ENTER , the software will automatically save the data into the selected address.
4. Return to step 2 to continue programming or press [ CLEAR ] to exit programming mode.
Figure 23: Hex Programming
Hex Digit Data Display for LED Keypads
Note: LCD keypads will display current data on the screen.
If the key is not lit, value = 0
Sum of the first row = second hex digit
Sum of the second row = first hex digit
Each key in the first 2 rows of the keypad represents a specific value when the key is lit, as shown above. If the key isn’t lit, the key represents 0. The sum of the values of the lit keys in the first row correspond to the second hex digit. The sum of the values of the lit keys in the second row correspond to the first hex digit as shown in the example below.
= Second digit = 8 + 2 = 10
= First digit = 4 + 2 + 1 = 7
Therefore 2-digit data = 7A
Note: Values 10 to 15 represent hex digits A to F respectively. See the keypads at left.
12 Reference & Installation Manual
advertisement
Related manuals
advertisement
Table of contents
- 5 Introduction
- 5 About This Manual
- 5 New Features
- 5 Main Features
- 5 Specifications
- 6 Installation
- 6 Location and Mounting
- 6 Earth Ground
- 6 AC Power
- 6 Backup Battery
- 7 Auxiliary Power Terminals
- 7 Battery Test
- 7 Keypad Function Test
- 7 Telephone Line Connection
- 8 Bell/Siren Output
- 8 Alarm Relay Outputs (738 Ultra; Optional)
- 8 Programmable Outputs (PGMs)
- 8 Keypad and Keyswitch Connections
- 9 Keypad Zone Connections
- 10 Connecting an Anti-Tamper Switch on an LED Keypad
- 10 Single Zone Input Terminal Connections
- 10 N.C. Contacts, Without EOL Resistor
- 11 N.O. and N.C. Contacts, With EOL Resistor (UL/cUL)
- 11 Recognition
- 11 Wire Fault Recognition (UL/cUL)
- 11 Advanced Technology Zone (ATZ) Connections
- 12 N.C. Contacts, Without EOL Resistor, ATZ Series
- 13 Recognition, ATZ Series
- 13 Wire Fault Recognition (UL/cUL), ATZ Series
- 13 N.C. Contacts, With ATZ Parallel Wiring
- 14 Fire Circuit
- 14 4-Wire Smoke Detector Connections (Standard Installation)
- 14 4-Wire Smoke Detector Connections (UL/cUL Installation)
- 14 2-Wire Smoke Detector Connections
- 14 Serial Output Connector
- 15 Status LED
- 15 Access Codes
- 15 Installer Code
- 15 Master and User Codes
- 15 User/Access Code Length
- 15 Duress
- 15 Installer Lock
- 15 Master Code Lock
- 16 Programming Methods
- 16 Espload Software
- 16 Keypad
- 16 Hex Programming
- 17 Hex Streamlined Section Programming
- 17 Decimal Programming
- 17 Feature Select Programming
- 18 Panel Settings for Espload
- 18 Panel Answer Options
- 18 Panel Identifier
- 18 PC Password
- 19 Computer Telephone Number
- 19 Call Espload
- 19 Answer Espload
- 19 Cancel Communication
- 19 Call Back
- 19 Automatic Event Buffer Transmission
- 20 Event Reporting
- 21 Reporting Options
- 21 Reporting Disabled
- 21 Regular Reporting
- 21 Split Reporting
- 21 Double Reporting
- 22 Monitoring Station Telephone Number 1 (MSTN1)
- 22 Monitoring Station Telephone Number 2 (MSTN2)
- 23 System Account Codes
- 23 Communicator Formats
- 23 Ademco Contact ID (All Codes)
- 24 Ademco Contact ID (Programmable Codes)
- 25 Ademco Express
- 25 Pager Reporting Format
- 25 Standard Pulse Formats
- 25 Pager Delay
- 25 Pager Format Transmission Options
- 25 Pager Report Event Option
- 26 Reporting Event Codes
- 26 Arming Codes
- 26 Disarming Codes
- 26 Alarm Codes
- 26 Restore Codes
- 26 Zone Shutdown Codes
- 26 Tamper Codes
- 27 Trouble/Trouble Restore Codes
- 27 Special Codes
- 27 Auto Test Report
- 28 Timed Test Transmission (738 Ultra only)
- 28 Manual Test Report
- 28 Power Failure Report Delay
- 28 Recent Close Delay
- 28 Report Zone Restore Options
- 28 Report Code Disarming Options
- 29 Zone Definitions
- 31 Zone Speed
- 31 Advanced Technology Zoning (ATZ)
- 31 ATZ Parallel Wiring
- 31 Intellizones
- 31 Intellizone Time Delay
- 31 Silent Zones
- 32 24Hr and 4-Wire Smoke Detector Fire Zones
- 32 Enable/Disable Zone 4 (728 Ultra) or Zone 11 (738 Ultra)
- 32 2-Wire Smoke Detector Recognition (Input 3)
- 32 2-Wire Smoke Detector Reset
- 32 Instant Zones
- 32 Follow Zones
- 33 Entry Delay
- 33 Entry Time Delay
- 33 Partitioning
- 33 System A/Stay Zones