Remote Control Unit (continued)
SENSOR button When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.
NOTE If the remote control is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.
Temperature Display Selector button This switches the temperature display between °C and °F.
Time Display Selector button This switches the time display between 24-hour time and 12-hour time.
ACL button (ALL CLEAR) Puts the remote control unit into pre-operation status. Always press this button after replacing the batteries and setting the S/M switch.
ADDRESS switch • The address switch changes to prevent mixing of signals from remote control units when two air conditioners are installed next to each other.
Normally, the address switch is set to A. For more information, please contact the dealer where you made the purchase.
• Normally, the tabs on the remote control unit should not be bent.
S/M (Single/Multiple switch) • Initially, the S/M switch is set to S (Single).
• Set this switch to M (Multiple) for multiple operation.
• Always press ACL button by a thin object such as the tip of a pen after setting the S/M switch.
NOTE When multiple indoor units are used and units in other rooms are already operating, they will be set to the same mode of operation as the operating indoor units.
NOTE The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.
Using the Remote Control Unit
How to Install Batteries
1.
Slide the cover in the direction indicated by the arrow and remove it.
2.
Install two AAA alkaline batteries.
Make sure the batteries point in the direction marked in the battery compartment.
3.
Use a thin object such as the tip of a pen to press the ACL button.
ACL button
NOTE • The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit’s display fails to light, or when the remote control cannot be used to change the air conditioner’s settings.
• Use two fresh leak-proof type-AAA alkaline batteries.
• In replacing batteries, follow the instructions as mentioned in the sub-section “How to Install Batteries”.
• If you do not use the remote control unit more than 1 month, take out the batteries.
10
Using the Remote Control Unit (continued)
How to Use the Remote
Control Unit
When using the remote control unit, always point the unit’s transmitter head directly at the air conditioner’s receiver.
Air conditioner
(Indoor unit)
Remote control unit
Receiver
(Transmitter head)
Remote Control Unit
Installation Position
The remote control unit may be operated either from a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places:
DO NOT • In direct sunlight
• Behind a curtain or other places where it is covered
• More than 8 m away from the air conditioner
• In the path of the air conditioner’s airstream
• Where it may become extremely hot or cold
• Where it may be subject to electrical or magnetic noise
• Where there is an obstacle between the remote control unit and air conditioner (since a check signal is sent from the remote control unit every
5 minutes)
Mounting the Remote Control
Unit
Before mounting the remote control unit, press the ON/OFF operation button at the mounting location to make sure that the air conditioner operates from that location. The indoor unit should make a beeping sound to indicate that it has received the signal.
Remote control unit mount
Rear side
Press
Mounting screws
4 x 16 (included)
Set in place
Hole
• To prevent loss of the remote control unit, you can connect the remote control unit to the mount by passing a string through the remote control unit and attachment hole.
When Holding the Remote
Control Unit
To take out the remote control unit, pull it forward.
• When using the remote control unit and during air conditioner operation, the transmitter on the remote control unit should be pointed toward the receiver on the indoor unit.
• Make sure that there are no objects between the remote control unit and receiver which could block the signal.
11
advertisement
Related manuals
advertisement
Table of contents
- 2 Features
- 3 Product Information
- 3 Alert Symbols
- 4 Installation Location
- 4 Electrical Requirements
- 4 Safety Instructions
- 5 Names of Parts
- 10 Using the Remote Control Unit
- 12 Operation with the Remote Control Unit
- 12 1. Automatic Operation
- 13 2. Manual Operation
- 14 3. Adjusting the Fan Speed
- 14 4. Fan Only
- 15 5. Night Setback Mode
- 16 6. QUIET Mode
- 16 7. HIGH POWER Mode
- 16 8. LED CLEAN Mode
- 17 Special Remarks
- 18 Setting the Timer
- 20 Using the 1-Hour OFF Timer
- 20 Tips for Energy Saving
- 21 Adjusting the Airflow Direction
- 22 Operation without the Remote Control Unit
- 22 Care and Cleaning
- 25 Troubleshooting
- 25 Operating Range