Pos: 75.23 /Ü berschriften/Ü berschriften 2/A-E/AAufbereiterdr ehzahl einstell en @ 248\mod_1396526275767_78.docx @ 1930518 @ 2 @ 1

Settings

10.4 Setting Conditioner Speed

Pos: 75.24 /Abkürzungen /C V-Ausführung @ 95\mod_1328530180147_78.docx @ 799128 @ @ 1

CV-Design

Pos: 75.25 /BA/Sicherheit/7. Gefahr enhinweise alt/Einstell arbeiten / Einstell ungen/Gefahr - Einstell ung en an der Maschi ne @ 0\mod_1196668628056_78.docx @ 10285 @ @ 1

Danger! - Settings on the machine

Effect: Danger to life, injuries or damage to the machine.

• Setting tasks must only be performed when the drive is switched off and the engine is at a standstill! Remove the ignition key!

Pos: 75.26 /BA/Ei nstellungen/M ähwer ke/Z etterdr ehzahl/Aufbereiterdr ehzahl einstell en Riemenscheiben EC F 360 CV/CR Bil d/T ext @ 245\mod_1396003473212_78.docx @ 1916562 @ @ 1

1

Pos: 75.27 /Layout Module /---------------Seitenumbr uch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1

2

EC-507-0

Fig. 44

Two conditioner speeds can be set on the belt drive. This affects conditioning effect and power consumption.

Maximum speed: 900 rpm (large pulley (1) top, small pulley (2) bottom).

Minimum speed: 600 rpm (small pulley (2) top, large pulley (1) bottom).

77