Electrical connection. Miele 11329860, KWT 6722 iS

Add to My manuals
92 Pages

advertisement

Electrical connection. Miele 11329860, KWT 6722 iS | Manualzz

*INSTALLATION*

Electrical connection

 Danger of electric shock!

The wine conditioning unit must only be switched on when it has been installed in accordance with the installation instructions.

Ground the wine conditioning unit.

The wine conditioning must not be grounded via a gas pipe.

If in doubt, have a suitably qualified and experienced electrician check that the installation complies with relevant regulations.

Do not install a fuse into neutral current or grounding electrical circuit.

Do not use extension cords or ungrounded (two prong) adapters.

Do not use a frayed or damaged power cord.

 Danger of electric shock!

For protection against electric shock this wine conditioning is equipped with a pole-free plug which is protected against reverse polarity. The plug must be grounded in the usual way.

Do not remove the round grounding connector pin from the plug.

Use only a grounded plug adapter.

Installation

Wait for 1 hour after installation before plugging the wine conditioning into the power supply. This allows coolant and refrigerator oil to settle in accordance with regulations.

Ensure that the voltage of the main power supply corresponds with the connection voltage of the wine conditioning. A power supply of 110 - 120 V,

60 Hz and 15 Amp (20 Amp for side-byside installation) with a NEMA 5-15 molded plug, which is protected by a main switch or a fuse, is required to operate the wine conditioning unit.

The manufacturer recommends operating the wine conditioning on a separate circuit to avoid overloading the electrical circuit.

All relevant legal electrical, fire and building regulations must be observed when installing the socket and/or the wine conditioning.

In certain countries wine conditioning are required to be connected to the electrical supply via a wall-mounted

ON/OFF switch.

To avoid the risk of fire, electric shock or other injuries installation and connection of the appliance must be carried out by a suitably qualified electrician in accordance with all relevant local and national regulations and standards, including fire prevention.

85

*INSTALLATION*

Installation

The outlet must be easily accessible in an emergency so that the wine conditioning unit can be quickly disconnected from the electrical supply in case of an emergency.

If the outlet is no longer accessible once the appliance has been installed, an all-pole disconnect device with a contact opening of at least 1/8" (3 mm) must be present on site. The disconnect device may be circuit breaker, a fuse, or a contactor (compliant with local regulations).

The plug and power cord must not come into contact with the back of the appliance as vibrations can cause damage to these components. This, in turn, could result in a short circuit.

Do not plug in other devices behind this wine conditioning unit.

Do not connect the wine conditioning unit to an inverter such as those used with an autonomous energy source e.g.

solar power . When switched on, peak loads in the system can cause the safety switch-off mechanism to be triggered. This can damage the electronic unit.

The wine conditioning unit must not be used with so-called energy-saving devices either. These reduce the amount of energy supplied to the wine conditioning unit, causing it to overheat.

If the power cord needs to be replaced, this must be done by a qualified technician.

86

Information for dealers

Demo mode  

The appliance can be demonstrated in the showroom or at exhibitions in

“Demo mode”. In this mode the control panel and interior lighting are active but the compressor remains turned off, so that the appliance does not cool down.

Turning on Demo mode

 Switch the wine conditioning unit off by touching the On/Off sensor.

The temperature shown in the display will go out and the power connection symbol   appears.

 Keep your finger on the    sensor until the    symbol appears in the display.

 Then release the    sensor.

Demo mode is turned on and the    symbol is illuminated in the display.

Turning off Demo mode

The    symbol is illuminated in the display.

 Touch and hold the    sensor.

 Touch the settings sensor.

All symbols available for selection will appear in the display and the    symbol flashes.

 At the same time, briefly touch the

On/Off sensor (without letting go of the    sensor).

 Touch the sensors for setting the temperature (    or    ) repeatedly until the    symbol flashes in the display.

 Touch the OK sensor to confirm your selection.

The  1   symbol flashes in the display

(meaning: Demo mode is active) and the    symbol is illuminated.

87

Information for dealers

 Touch the    or    sensor so that the symbol  0  appears in the display

(meaning: Demo mode is inactive).

 Touch the OK sensor to confirm your selection.

The selected setting will be adopted and the    symbol will flash.

 Touch the settings sensor to leave the settings mode.

Otherwise the appliance will exit the settings mode automatically after approximately one minute.

Demo mode is turned off and the    symbol disappears.

88

Please have the model and serial number of your appliance available when contacting Technical Service.

U.S.A.

Miele, Inc.

National Headquarters

9 Independence Way

Princeton, NJ 08540

Phone:

Fax:

800-843-7231

609-419-4298 www.mieleusa.com

Technical Service & Support

Phone: 800-999-1360

Fax: 888-586-8056

[email protected]

International Headquarters

Miele & Cie. KG

Carl-Miele-Straße 29

33332 Gütersloh

Germany

Canada

Importer

Miele Limited

Headquarters and Miele Centre

161 Four Valley Drive

Vaughan, ON L4K 4V8 www.miele.ca

Customer Care Centre

Phone: 800-565-6435

905-532-2272 [email protected]

KWT 6722 iS en-US M.-Nr. 11 347 500 / 00

advertisement

Key Features

  • Built-in Compressor wine cooler 80 bottle(s) Number of temperature zones: 2 Black
  • Number of shelves: 8 Number of doors: 1
  • Wine cooler net capacity: 254 L
  • 32 dB
  • 176 kWh
  • Interior light Temperature alarm

Related manuals

advertisement

Table of contents