Description of the signaling LEDs. ABB TLE Scalable UL Series UPS 86 Pages
Description of the signaling LEDs. ABB TLE Scalable UL Series UPS
advertisement
25/86
6.1.2
Description of the signaling LEDs
TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
Fig. 6.1.2-1 LCD screen
UPS model
Date (format “MM/DD/YYYY”).
Time AM or PM (format “HH.MM.SS”). eBoost (green color)
LED ON/lit indicates that the UPS is operating in eBoost™ mode.
IEMi (green color)
LED ON/lit indicates that the UPS is operating in IEMi mode.
Service Key (yellow color)
Key for disabling the Service Key procedure.
Used only by the ABB Service Center.
LEDS UPS STATUS
LED LOAD PROTECTED (green color)
When lit, indicates that the UPS is functioning correctly and the Load is system protected (Load supplied either from Inverter or from Automatic Bypass in case of eBoost™ Operation Mode).
When blinking, indicates that a regular maintenance service is needed (SERVICE REQUIRED).
May be reset by an ABB Service Technician only.
See Section 9 – Maintenance – Service check.
The LED is OFF when the “Q1 – UPS output switch” is open, indicating that the Inverter is in service mode, not supplying the Load.
26/86 TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
LED ALARM (yellow color)
It blinks when one or more alarm is activated. The internal Buzzer is ON.
The LED remains blinking (with the alarm condition still present) and the buzzer stops when the key “MUTE” is pressed.
The LED ALARM is also lighted when the Load is not protected by UPS or in case “Q1 – UPS output switch” is open.
LED STOP OPERATION (red color)
•
•
It warns about the imminent Inverter stop (default parameter = 3 min.) and the consequent Load shut-down as result of:
The Battery is fully discharged and the Load cannot be transferred on Utility.
Overtemperature or overload condition (>102%) and the Load cannot be transferred on Utility.
Bypass
Data regarding Bypass.
See Section 6.2.
Rectifier
Data regarding Rectifier.
See Section 6.2.
Load output
Data regarding Load.
See Section 6.2.
Battery
Data regarding Battery.
See Section 6.2.
Green color: indicates Battery charged.
Yellow color: indicates STOP OPERATION status.
Red color: indicates low Battery.
27/86 TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
LEDs on Synoptic Diagram
LED 1 Rectifier
LED 2
LED 3
Inverter
Booster/Battery charger
LED 4 Automatic Bypass
LED 5 LOAD
Examples of typical scenarios in the Synoptic Diagram:
Load supplied by Inverter Load supplied by Automatic Bypass
“SEM - Super Eco Mode” Operation Mode Load supplied by Battery
IEMi Operation Mode, Unit on-line IEMi Operation Mode, Unit stand-by
advertisement
Related manuals
advertisement
Table of contents
- 6 Safety rules
- 8 Safety symbols and warnings
- 8 Cyber security
- 9 Layout
- 9 Layout TLE Scalable Series 40 to
- 10 Introduction
- 11 Description
- 12 Block diagram and main elements
- 13 Operation modes
- 13 Normal VFI Operation Mode (Voltage Frequency Independent)
- 13 SEM Operation Mode (Super Eco Mode)
- 14 Utility Failure Operation
- 14 Utility Recovery Operation
- 15 Automatic Bypass
- 16 RPA Parallel System operation
- 16 Introduction to the RPA Parallel System
- 17 Features of RPA Parallel System
- 17 System control
- 17 Synchronization
- 17 Load sharing
- 18 IEMi Operation Mode (option)
- 19 UPS paralleled on the same Battery
- 20 Service and technical support
- 20 Warranty
- 21 Recycling instructions
- 22 Control Panel
- 23 LCD screen
- 23 Home screen
- 24 Description of the selection keys
- 25 Description of the signaling LEDs
- 28 Measures
- 32 Events
- 34 Events (alarms and messages)
- 34 Alarms list
- 38 Messages list
- 41 Setup
- 47 Commands
- 51 RPA Parallel System
- 53 Operation
- 54 Procedures for single TLE Scalable Series 40 to
- 54 Initial start-up of the TLE Scalable Series 40 to
- 58 Complete UPS shut-down
- 59 Restore to normal operation after “System shutdown” with Load not supplied
- 60 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 61 Procedures single TLE Scalable Series 40 to 150 functioning as Frequency Converter
- 61 Initial Start-up of the TLE Scalable Series 40 to 150 as Frequency Converter
- 65 Complete shut-down of the TLE Scalable Series 40 to 150 as Frequency Converter
- 66 Restore to normal operation after “System shutdown” with Load not supplied
- 67 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 68 Procedures for TLE Scalable Series 40 to 150 RPA Parallel System
- 68 TLE Scalable Series 40 to 150 RPA Parallel System start-up
- 73 Separate a UPS Unit from the RPA Parallel System (System Redundancy)
- 75 Reconnect a UPS Unit to RPA Parallel System
- 77 Complete RPA Parallel System shut-down
- 78 Restore to normal operation after “System shutdown” with Load not supplied
- 80 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 82 Options
- 82 Connectivity options
- 82 Options in UPS cabinet
- 82 Options in additional cabinets
- 83 Maintenance
- 83 Service check
- 83 Fans and ventilation
- 83 Other components with limited lifetime
- 84 Battery
- 84 UPS room conditions and temperature
- 84 Preventive maintenance program
- 85 Notes
- 85 Notes Form