MEASURES
The MEASURES mode is entered any time the
“ MEASURES ” key is pressed.
The LCD screen will indicate a series of screenshots showing the measures of all electric parameters like
AC, DC and various statistics.
In this mode the keys perform the following functions:
Return to HOME screen.
Shows the main screen EVENTS.
See Section 6.3.
Shows the main screen SETUP.
See Section 6.4.
Shows the main screen COMMANDS.
See Section 6.5.
Shows the operating status of the RPA PARALLEL SYSTEM.
See Section 6.6.
Key to reset general alarm and buzzer.
Shows the screen Battery.
Shows the screen Rectifier.
Shows the screen Bypass.
Shows the screen Inverter.
Shows the screen Load.
Shows the screen Booster.
29/86 TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
Battery screen
Voltage
The Battery voltage.
Current
The Battery current (negative values correspond to the discharge of the Battery).
Temperature
The temperature of the Battery (“XXX” indicates sensor disabled).
Autonomy
The estimated backup time with the present Load.
Note: the backup time is computed given the Unit Load.
Therefore, during IEMi Operation Mode, On-line Units may show a reduced backup time. However, following a power outage, all Inverters are forced on-line.
Therefore, during Battery operation every Unit shows the true Battery autonomy.
Charge level
The Battery charge level.
On battery time
Total operating time of the UPS on Battery (in hours).
BATTERY DISCHARGE COUNTER / Residual Charge Level
The number of discharges combined with the percentage of the available residual Battery capacity at the time
Utility power is restored.
Battery charger status
Battery charge status (Off / Float / Boost).
Rectifier screen
Frequency
The input frequency of the Rectifier.
Voltage L1 / Voltage L2 / Voltage L3
3-phase input Utility voltage PHASE /NEUTRAL.
Voltage DC-link 1
DC-Link 1 voltage.
Voltage DC-link 2
DC-Link 2 voltage.
Main failure count
Total number of times a gap of Utility in the Rectifier has been reordered.
Temperature
Rectifier inlet L1 Coil temperature (Normal / Alarm).
Temperature 1 / 2 / 3
Temperature of the Rectifier bridge (Power Module 1 / 2 / 3).
30/86 TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
Bypass screen
Frequency
The frequency of the input Utility.
Voltage L1 / Voltage L2 / Voltage L3
3-phase input Utility voltage PHASE /NEUTRAL.
Current L1 / Current L2 / Current L3
Input Utility current for the 3-phases.
Main failure count
The total number of minor Utility faults (Bypass Utility out of tolerance faults).
Number of fast transients
The number of fast transients occurred on the Bypass Utility on the last seven days.
Bypass quality index
The statistic evaluation in % (100= good; 0= bad) of the Bypass utility.
Temperature
The temperature of the SSM - Static Switch Module (°C/ Alarm).
Status
Bypass status: free / blocked.
Temperature
“XXX” indicates disabled function.
Temperature 1 / 2 / 3
Temperature of the Inverter bridge (Power Module 1 / 2 / 3).
Inverter screen
Frequency
The output frequency of the Inverter.
Voltage L1 / Voltage L2 / Voltage L3
3-phase output Utility voltage PHASE/NEUTRAL.
Status
The synchronization status of the Inverter with respect to Utility:
Synchronized.
Not synchronized.
31/86 TLE Scalable Series 40 to 150 UL S1 UPS User Manual / REV-B
Active power
Apparent power
Power factor
Status
Inverter operating time
Apparent power
UPS operation time
Active Power
SEM operation time
Overload counter
IEMi operation time
Load screen
Voltage L1 / L2 / L3
Output voltage PHASE/NEUTRAL for each phase.
Current L1 / L2 / L3
The output current as RMS values for each phase.
Percent load L1 / L2 / L3
The output Load as percentage for each phase.
Load active power (kW) for each phase.
Load apparent power (kVA) for each phase.
Load power factor: (+) inductive Load / (-) capacitive Load
Source of the power supplied to the Load.
Total operating time for the Inverter (in hours).
Total apparent Load power (kVA).
Total operating time for the UPS (in hours).
Total effective Load power (kW).
Total operating time for the UPS in “SEM - Super Eco Mode” Operation Mode (in hours).
Total number of detected output overloads.
Total operating time for the UPS in IEMi Operation Mode (in hours).
This counter is displayed only when IEMi Operation Mode is available (option).
Voltage DC-link 2
Status
Temperature
Temperature 1 / 2 / 3
Booster screen
Battery voltage
The Battery voltage.
Battery current
The Battery current (negative values correspond to the discharge of the Battery).
Voltage DC-link 1
DC-link 1 voltage.
DC-link 2 voltage.
Booster status (Off / Booster / Charger).
“XXX” indicates disabled function.
Temperature of the Booster (Power Module 1 / 2 / 3).
advertisement
Related manuals
advertisement
Table of contents
- 6 Safety rules
- 8 Safety symbols and warnings
- 8 Cyber security
- 9 Layout
- 9 Layout TLE Scalable Series 40 to
- 10 Introduction
- 11 Description
- 12 Block diagram and main elements
- 13 Operation modes
- 13 Normal VFI Operation Mode (Voltage Frequency Independent)
- 13 SEM Operation Mode (Super Eco Mode)
- 14 Utility Failure Operation
- 14 Utility Recovery Operation
- 15 Automatic Bypass
- 16 RPA Parallel System operation
- 16 Introduction to the RPA Parallel System
- 17 Features of RPA Parallel System
- 17 System control
- 17 Synchronization
- 17 Load sharing
- 18 IEMi Operation Mode (option)
- 19 UPS paralleled on the same Battery
- 20 Service and technical support
- 20 Warranty
- 21 Recycling instructions
- 22 Control Panel
- 23 LCD screen
- 23 Home screen
- 24 Description of the selection keys
- 25 Description of the signaling LEDs
- 28 Measures
- 32 Events
- 34 Events (alarms and messages)
- 34 Alarms list
- 38 Messages list
- 41 Setup
- 47 Commands
- 51 RPA Parallel System
- 53 Operation
- 54 Procedures for single TLE Scalable Series 40 to
- 54 Initial start-up of the TLE Scalable Series 40 to
- 58 Complete UPS shut-down
- 59 Restore to normal operation after “System shutdown” with Load not supplied
- 60 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 61 Procedures single TLE Scalable Series 40 to 150 functioning as Frequency Converter
- 61 Initial Start-up of the TLE Scalable Series 40 to 150 as Frequency Converter
- 65 Complete shut-down of the TLE Scalable Series 40 to 150 as Frequency Converter
- 66 Restore to normal operation after “System shutdown” with Load not supplied
- 67 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 68 Procedures for TLE Scalable Series 40 to 150 RPA Parallel System
- 68 TLE Scalable Series 40 to 150 RPA Parallel System start-up
- 73 Separate a UPS Unit from the RPA Parallel System (System Redundancy)
- 75 Reconnect a UPS Unit to RPA Parallel System
- 77 Complete RPA Parallel System shut-down
- 78 Restore to normal operation after “System shutdown” with Load not supplied
- 80 Restore to normal operation after “EPO - Emergency Power Off” with Load not supplied
- 82 Options
- 82 Connectivity options
- 82 Options in UPS cabinet
- 82 Options in additional cabinets
- 83 Maintenance
- 83 Service check
- 83 Fans and ventilation
- 83 Other components with limited lifetime
- 84 Battery
- 84 UPS room conditions and temperature
- 84 Preventive maintenance program
- 85 Notes
- 85 Notes Form