Base Purge

Base Purge

Base purge results in the purging of the base (A) chem ical through the dispense valve. Base purging prevents mixed material within the dispense applicator from cur ing. The machine will remain pressurized and electri cally connected.

1. Navigate to the

Purge/Prime

screen.

NOTE: Verify both pumps are activate.

2. Close the catalyst (B) ball valve located near the dispense applicator.

3. Dispense material into a waste container until only the base (A) chemical is present.

4. Engage the trigger lock.

46 3A2894U