Circuits

Page

22-31.....

Heated

32-33.....

Nonheated

34-35.....

NIV/CPAP.Circuits

36..........

Heated.Wire.Adapters.and.Temperature.Probes

37-40.....

Circuit.Accessories

carefusion.com

Circuits Heated

RT240

RT235

RT236

Fisher & Paykel Healthcare EVAQUA

Circuit Kits

EVAQUA

technology allows water vapor to diffuse through the expiratory limb wall before it has an opportunity to condense into liquid water within the circuit limb or ventilator.

Code

D=Dual Heat

DS=Dual-Single Heat

S=Single Limb

Circuit

Length

For Use With

Ventilator

Humidifiers

RT240

D 5’

RT235

D

RT236

D

4’

4’

18*, 19*, 20, 21, 22,

23*, 24, 26*, 27, 28

MR850

MR730

25

*.Verify.Bias.Flow.Protocol.is.>.4.lpm.otherwise.use.RT236

MR850

Heater Wire

Adapter

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

Y

Y

“Y”

Style

Y

Temp Probe

Key

Adult Ventilator

. 1.. Draeger.Evita.1,.2,.Dura,.Evita.4,.Evita.XL,.Savina

. 2.. eVent.Inspiration..

. 3.. GE.Engstrom.Carestation,.I.vent.

.

. 4.. Hamilton.Amadeus,.Galileo,.Raphael,.Veolar

. 6.. Maquet.300A,.900C,.Servo.i. .

. 7.. Newport.E.100M,.Wave.E200,.e500.Wave

. 9.. PB.840,.7200,.740,.760.

.

.11.. CareFusion.Bear

®

.1,.2,.5,.1000.ventilators.

.12.. CareFusion.Bird

®

.8400.ventilator.

.

.13.. CareFusion.AVEA

®

,.VELA

®

,.TBIRD

®

,.EnVe

®

.ventilators

.14.. Respironics.Esprit..

Cat. No.

RT240

RT235

RT236

Description

Adult breathing circuit with EVAQUA

expiratory limb

Neonatal breathing circuit with EVAQUA

expiratory limb high flow

Neonatal breathing circuit with EVAQUA

expiratory limb low flow

Neonatal Ventilators

.18.. PB840

.19.. Draeger.Babylog.8000,.Evita

.20.. Infrasonics.Infant.Star.500,.950

.21.. Newport.Breeze

®

.E150

.22.. Sechrist.IV100B,.IV200,.Millenium

.23.. CareFusion.AVEA

®

,.Bear.Cub

®

.750.PSV

.24.. CareFusion.Bird

®

.VIP.ventilator

.25.. Maquet.300A,.Servo.i

.26.. Hamilton.G5

.27.. Biomed.Devices

.28.. Impact.Eagle

Qty.

10/cs

10/cs

10/cs

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

MDI

Port

Pressure

Line

Dry

Gas

Line

• •

H

2

O

Trap

Pressure

Pop Off

. D. Dual.Heat.

.DS. Dual-Single.Heat.

. S. Single.Limb.

. Y. Standard.“Y”.

22

carefusion.com

Circuits Heated

RT202

Fisher & Paykel Healthcare High-Performance

Circuit Kits

By combining the superior performance of Fisher & Paykel Healthcare’s high-performance circuits with the clinician-preferred MR290 auto- feed chambers, we are able to offer parallel wire circuit kits that combine all of these critical system components into one purchase.

That means more user convenience, less packaging and improved set-up times. Autofeed Chamber MR290 included with each kit.

RT210

RT329

Code

D=Dual Heat

DS=Dual-Single Heat

S=Single Limb

Circuit

Length

RT202

RT210

RT211

RT215

RT324

RT329

S

D

D

DS

S

S

5’

5’

5’

5’

4’

4’

For Use

With

Ventilator

Humidifiers

2, 10, 29, 30,

31, 33, 34

1, 2, 3, 4, 6,

7, 9, 12, 13,

30, 32, 33

MR850

MR730

MR850

MR730

5, 11

14

17

Infant nasal high flow only

MR850

MR730

MR850

MR730

MR850

MR730

MR850

MR730

Heater Wire

Adapter

Parallel

(P) or Y

Style

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

P

P

P

Temp Probe

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

MDI

Port

Pressure

Line

Dry

Gas

Line

Exp

Limb

H

2

O

Trap

Pressure

Pop Off

Air

Entrainer

Key

Adult Ventilator

. 1.. Draeger.Evita.1,.2,.Dura,.Evita.4,.Evita.XL,.Savina

. 2.. eVent.Inspiration..

. 3.. GE.Engstrom.Carestation,.I.vent.

.

. 4.. Hamilton.Amadeus,.Galileo,.Raphael,.Veolar

. 5.. Infrasonics..Adult.Star.2000. .

. 6.. Maquet.300A,.900C,.Servo.i. .

. 7.. Newport.E.100M,.Wave.E200,.e500.Wave

. 9.. PB.840,.7200.

.

.10.. CareFusion.LTV

®

,.ReVel

.ventilators.

.

.11.. CareFusion.Bear

®

.1,.2,.5,.1000.ventilators.

.12.. CareFusion.Bird

®

.8400.ventilators.

.

.13.. CareFusion.AVEA

®

,.VELA

®

,.TBIRD

®

,.EnVe

®

.ventilators

.14.. Respironics.Esprit..PB740,.PB760.

CPAP/NPPV Systems

.17.. CareFusion.SiPAP,.nCPAP.and.P.driver.systems

Homecare Ventilators

.29.. PB.Achieva,.LP10,.LP6

.30.. PB.540

.31.. Newport.HT50,.HT70

.32.. CareFusion.Legacy.ventilator

.33.. CareFusion.LTV

®

.ventilator

.34.. Respironics.Trilogy100,.PLV102

. D. Dual.Heat.

.DS. Dual-Single.Heat.

. S. Single.Limb.

. P. Parallel.“Y”.

. Y. Standard.“Y”.

Cat. No.

Description

High Performance

RT202 Vent circuit with MR290 single limb heated

RT210

RT211

RT215

Vent circuit with MR290 dual heated

Vent circuit with MR290 dual heated w/press line

Vent circuit with MR290 insp heated, w/H

2

O trap

Special Circuit

RT202 Nasal high flow circuit

RT324

RT329

CPAP / O

2

circuit kit with chamber

Oxygen therapy kit with chamber and pop off valve carefusion.com

23

Circuits Heated

RT110

RT130

RT111

RT131

RT114

Fisher & Paykel Healthcare

High Performance Circuits

Fisher & Paykel Healthcare offer a line of high-performance circuits that have spiral heated wire technology that is unique in the industry.

This technology increases the heating surface area in the circuit for superior condensate control and allows for delivery of optimal humidity to patients. Fisher & Paykel High Performance Circuits are part of the MR850 humidification system and may also be used with the MR730 humidifiers. Fisher & Paykel circuits also feature parallel Y, built-in MDI port, proximal pressure line, adapter kits and water traps, depending on the circuit configuration.

RT132

RT137

24

carefusion.com

Circuits Heated

Code Htd/Non Htd

Circuit

Length

For Use With

Ventilator

Humidifiers

RT110

D 5’

1, 2, 3, 4, 6,

7, 9, 12, 13,

30, 32, 33

MR850

MR730

RT111

RT114

RT130

D

S

DS

5’

5’

4’

5, 11

2, 29, 30,

31, 33, 34

25

MR850

MR730

MR850

MR730

MR850

MR730

RT131

DS 4’

18*, 19*, 20, 21,

22, 23*, 24, 26*,

27, 28

MR850

MR730

RT132

RT137

S

DS

4’

5’

17

14

MR850

MR730

MR850

MR730

*.Verify.Bias.Flow.Protocol.is.>.4.lpm.otherwise.use.RT236

Key

Adult Ventilator

. 1.. Draeger.Evita.1,.2,.Dura,.Evita.4,.Evita.XL,.Savina

. 2.. eVent.Inspiration..

. 3.. GE.Engstrom.Carestation,.I.vent.

.

. 4.. Hamilton.Amadeus,.Galileo,.Raphael,.Veolar

. 5.. Infrasonics..Adult.Star.2000. .

. 6.. Maquet.300A,.900C,.Servo.i. .

. 7.. Newport.E.100M,.Wave.E200,.e500.Wave

. 9.. PB.840,.7200.

.

.11.. CareFusion.Bear

®

.1,.2,.5,.1000.ventilators.

.12.. CareFusion.Bird

®

.8400.ventilator.

.

.13.. CareFusion.AVEA

®

,.VELA

®

,.TBIRD

®

.ventilators

.14.. Respironics.Esprit,.PB740,.PB760.

CPAP/NPPV Systems

.17.. CareFusion.SiPAP,.nCPAP.and.P.driver.systems

Heater Wire

Adapter

Y Style

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

P

P

SW

SW

P

Temp Probe

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

Neonatal Ventilators

.18.. PB840

.19.. Draeger.Babylog.8000,.Evita

.20.. Infrasonics.Infant.Star.500,.950

.21.. Newport.Breeze

®

.E150

.22.. Sechrist.IV100B,.IV200,.Millenium

.23.. CareFusion.AVEA

®

,.Bear.Cub.750.PSV

.24.. CareFusion.Bird

®

.VIP.ventilator

.25.. Maquet.300A,.Servo.i

.26.. Hamilton.G5

.27.. Biomed.Devices

.28.. Impact.Eagle

MDI

Port

Cat. No.

Description

High Performance

RT110 Vent circuit, dual heated

RT111

RT114

Vent circuit, dual heated with pressure line

Vent circuit, single heated

RT130

RT131

Neonatal ventilator circuit < 4 LPM

Neonatal Ventilator Circuit > 4 LPM

RT137 Vent circuit, dual limb, single heated

Special Circuit

RT132 Infant continuous flow breathing circuit

Accessories

900MR805

900MR806

900MR869

900MR900

900MR901

900MR569

Pressure

Line

Dry

Gas

Line

H

2

O

Trap

Pressure

Pop Off

Air

Entrainer

Homecare Ventilators

.29.. PB.Achieva,.LP10,.LP6

.30.. PB.540

.31.. Newport.HT50,.HT70

.32.. CareFusion.Legacy.ventilator

.33.. CareFusion.LTV

®

.ventilator

.34.. Respironics.Trilogy100,.PLV102

.DS. Dual-Single.Heat.

. S. Single.Limb.

. Y. Standard.“Y”.

. P. Parallel.“Y”.

.SW. Swivel.“Y”.

Heater wire adapter-dual limb, MR850

Heater wire adapter-single limb, MR850

Temperature probe, MR850

Heater wire adapter for dual heated wire circuits for a MR730

Heater wire adapter for single heated wire circuits for a MR730

Temperature probe, MR730 carefusion.com

25

Circuits Heated

Air

Life

Circuits—Adult Parallel Wire

All circuits are made with corrugated tubing and have a temperature probe tee and inspiratory and expiratory limbs that disconnect at the

“Y.” Circuits contain hose clips, but no tube hangers.

All circuits are designed exclusively for use with Fisher & Paykel

Healthcare Humidifiers MR850, MR730 and HC500, and come with parallel wires. Circuits come assembled and ready to use.

Code

D=Dual Heat

DS=Dual-

Single Heat

S=Single Limb

RT500-853

D

RT507-853

D

RT510-853

D

RT600-850

S

RT607-853

D

RT607-854

S

RT609-855

S

Circuit

Length

5’

5’

5’

6’

6’

6’

6’

Key

Adult Ventilator

. 1.. Draeger.Evita.1,.2,.Dura,.Evita.4,.Evita.XL,.Savina

. 2.. eVent.Inspiration..

.

. 3.. GE.Engstrom.Carestation,.I.vent.

.

. 4.. Hamilton.Amadeus,.Galileo,.Raphael,.Veolar.

. 6.. Maquet.300A,.900C,.Servo.i. .

. 7.. Newport.E.100M,.Wave.E200,.e500.Wave

. 9.. PB.840,.7200,.740,.760

.10.. CareFusion.LTV

® ,.ReVel

™ .ventilators

.11.. CareFusion.Bear

®

.1,.2,.5,.1000.ventilators

Cat. No.

RT500-853

RT507-853

RT510-853

RT600-850

RT607-853

RT607-854

RT609-855

Description

Adult 5’ heated circuit with “Y”

Adult 5’ heated circuit with “Y”

Adult dual heated circuit

Adult 6’ heated single limb circuit

Adult 6’ heated circuit with “Y” Port

Adult 6’ heated circuit with “Y” wye

Circuit adult 6’ port vent

For Use With

Ventilator

Humidifiers

Heater Wire

Adapter

Parallel Y style

Temp Probe

Exh

Valve

MDI

Port

Pressure

Lines

Dry

Gas

Line

1, 2, 3, 4, 6,

7, 9, 11, 12,

13, 14, 30

1, 2, 3, 4, 6,

7, 9, 11, 12,

13, 14, 30

1, 2, 3, 4, 6,

7, 9, 11, 12,

13, 14, 30

2, 10, 29, 30,

31, 33, 34

1, 2, 3, 4, 6,

7, 9, 11, 12,

13, 14, 30

14

29, 30, 31,

32, 34

MR850

MR730

900MR805

900MR900

MR850

MR730

MR850

MR730

MR850

MR730

MR850

MR730

MR850

MR730

MR850

MR730

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR806

900MR900

900MR806

900MR900

Y

Y

P

N/A

Y

Y

N/A

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

(

1

8

and

3

16

)

.12.. CareFusion.Bird

®

.8400.ventilator

.13.. CareFusion.AVEA

®

,.VELA

®

,.TBIRD

®

.ventilators

.14.. Respironics.Esprit

Homecare Ventilators

.29.. PB.Achieva,.LP10,.LP6

.30.. PB.540

.31.. Newport.HT50*

.32.. CareFusion.Legacy.ventilator

.34.. Respironics.Trilogy100,.PLV102

Qty.

20/cs

20/cs

20/cs

20/cs

20/cs

20/cs

20/cs

Exp

Limb

H

2

O

Trap

(5276)

Elbow

Omni-Flex

Connector

. D. Dual.Heat.

.DS. Dual-Single.Heat.

. S. Single.Limb.

. P. Parallel.“Y”.

. Y. Standard.“Y”.

RT507-853

26

carefusion.com

Circuits Heated

Air

Life

Circuits—Adult Series Wire

Lightweight and flexible, these circuits offer low compliance while delivering temperature control with minimal rainout. All circuits are made with corrugated tubing and have a temperature probe tee at the “Y.”

All circuits feature an elbow connection, contain hose clips and tube hangers and are designed exclusively for use with Fisher & Paykel

Humidifiers MR730 (use with electrical adapter 0060-23). Circuits come assembled and ready to use.

Cat. No.

Circuit

Length

9066-HS7

6'

7102-HS7

5'

9061-HS7

6'

9037-HS7

5'

For Use With

Ventilators

4, 5, 6, 9, 10

2, 4, 5, 6, 9, 10

2, 3, 4, 5, 6, 7,

8, 9, 10

2, 3, 4, 5, 6, 7,

8, 9, 10

P

Y

“Y”

Style

P

Y

Omni-Flex

Connector

Key

. 2.. CareFusion.Bear

®

.1000,.Bear

®

.5,..

1

. 3.. Bird

®

.6400.

1

/

8

/

4

".pressure.line.ventilators

".pressure.line.ventilator

. 4.. CareFusion.Bird

®

.8400,.TBIRD

®.

ventilators

. 5.. Draeger.Evita

.8000

. 6.. Hamilton.Veolar

®

Probe Port on “Y”

Pressure Port on “Y”

Pressure

Lines

1

4

"

1

8

",

1

4

"

1

8

",

1

4

"

Neb.

Tee

6"

Valve

Tee

. 7.. Infrasonics.Adult.Star

.

1

/

8

".pressure.line

. 8.. Newport.Breeze

®

,.Newport.Wave

®

.

1

. 9.. Nellcor.Puritan.Bennett

®

.7200,.840

.10.. Siemens

®

.300/900C

/

8

".pressure.line

6"

6"

MDI Dual

Spray

Dry Gas

Line

18"

24"

18"

6" 18"

.T@Y. Probe.Tee.at.“Y”.

.

P. Parallel.“Y”.

.

Y. Standard.“Y”

Qty.

20/cs

20/cs

20/cs

20/cs

Inspiratory line RT114

Adult Inspiratory Lines

Air

Life

™ circuit inspiratory lines each have a temperature probe adapter.

Inspiratory Lines 1005-H05 and 1006-H05

are designed for use with Fisher & Paykel Healthcare Humidifiers MR700, MR720 and MR730, and require use of Heater Wire Adapter 0060-20 or 900MR559.

Inspiratory Line RT114

is for use with Fisher & Paykel Healthcare

MR850, MR700-series and HC500 humidifiers. Electrical adapter for the MR850 is 900MR801. Electrical adapter for the MR700 series and for HC500 is 900MR901.

Cat. No.

1006-H05

Circuits

Nonheated-CPAP

Length

6' (72")

Qty.

20/cs carefusion.com

27

Circuits Heated

Air

Life

Circuits—Pediatric Parallel Wire

Circuits are made with corrugated tubing with a temperature probe tee and inspiratory and expiratory limbs that disconnect at the “Y.”

All circuits are designed exclusively for use with Fisher & Paykel

Healthcare Humidifiers MR850, MR730 amd HC500, and come with parallel wires.

Code

D=Dual Heat

DS=Dual-Single

Heat

S=Single Limb

Circuit

Length

For Use with

Ventilator

Humidifiers

RT409-852

RT509-852

D

D

4 ft

5 ft

1, 2, 3, 4, 6, 7,

9, 11, 12, 13,

14, 30

1, 2, 3, 4, 6, 7,

9, 11, 12, 13,

14, 30

MR850

MR730

MR850

MR730

*.Verify.Bias.Flow.Protocol.is.>.4.lpm,.otherwise.use.RT236.or.RT130

Heater Wire

Adapter

900MR805

900MR900

900MR805

900MR900

Parallel

Y Style

Y

Y

Temp Probe

Exh

Valve

900MR869

900MR569

900MR869

900MR569

MDI

Port

Pressure

Line

Dry

Gas

Line

Exp

Limb

H

2

O

Trap

(

1

4

and

1

8

) •

(

1

4

and

1

8

) •

Elbow

Omni-Flex

Connector

Key

Ventilators

. 1.. Draeger.Evita.1,.2,.Dura,.Evita.4,.Evita.XL,.Savina

. 2.. eVent.Inspiration..

.

. 3.. GE.Engstrom.Carestation,.I.vent.

.

. 4.. Hamilton.Amadeus,.Galileo,.Raphael,.Veolar.

. 6.. Maquet.300A,.900C,.Servo.i. .

. 7.. Newport.E.100M,.Wave.E200,.e500.Wave

. 9.. PB.840,.7200,.740,.760

.11.. CareFusion.Bear

®

.1,.2,.5,.1000.ventilators

.12.. CareFusion.Bird

®

.8400.ventilator

.13.. CareFusion.AVEA

®

,.VELA

®

,.TBIRD

®

,.EnVe.ventilators

.14.. Respironics.Esprit

Homecare Ventilators

.30.. PB.540

. D. Dual.Heat.

.DS. Dual-Single.Heat.

. S. Single.Limb.

. P. Parallel.“Y”.

. Y. Standard.“Y”

Cat. No.

RT409-852

RT509-852

Description

Ped 4’ dual heated circuit

Ped 5’ dual heated circuit

Qty.

20/cs

20/cs

Put the power of CareFusion to work for you

At.CareFusion,.we.offer.our.expertise.in.getting.product.to.healthcare.providers.quickly.and.cost-effectively...

Each.day.we.manufacture.millions.of.products.and.make.thousands.of.deliveries.to.healthcare.facilities..More.

importantly,.we.know.that.the.needs.of.each.of.our.customers.are.unique..We.can.help.you.find.the.right..

mix.of.products.to.maximize.value.without.sacrificing.clinical.performance.

Ask.your.CareFusion.sales.representative.how.you.can.benefit.from.our.free.product.mix.analysis.and.put.our..

logistics.expertise.to.work.for.you.today.

28

carefusion.com

Circuits Heated

Air

Life

Circuits—Infant Series Wire

Dual-heated corrugated tube circuits with a removable unheated extention. Circuits come assembled and are ready for use.

Cat. No.

Tube

Type

Length

Insp.

Length

Exp.

1208-4H1

C

7441-4S2

C

7582-4S2

C

9053-4S2

C

9054-4S2

C

48"

54"

66"

48"

48"

48"

48"

60"

48"

48"

For Use With

Ventilators

All below, except

Bird VIP

®

or

Bear Cub

®

750

All listed below

All listed below

All listed below

All listed below

Fisher & Paykel

Humidifiers

MR630

MR730

MR730

MR730

MR730

MR730

Key

1.. CareFusion.Bear.BP200

®

,.Bear.Cub

®

.750,.

1

. 2.. CareFusion.Bear.Cub

®

,.

3

/

16

/

8

".pressure.line.ventilators

".pressure.line.ventilator

. 3.. CareFusion.Bird

®

.8400,.TBIRD

®

.ventilators

. 4.. CareFusion.Bird

®

.VIP,.

1

/

8

".pressure.line.ventilator

. 5.. Draeger.Baby.Log

.8000

Electrical Adapter

(Pigtail)

0045-23

900MR555

0060-23

0060-23

0060-23

0060-23

“Y”

Style

Y

Y

Y

Y

Y

Probe

Tee

12"

18"

18"

T@Y

12"

. 6.. Hamilton.Amadeus,.Veolar

®

. 7.. Infrasonics.Star

.950,.500,.

1

. 8.. Newport.Breeze

®

,.Newport.Wave

®

,.

1

.10.. Sechrist

®

.IV,.200,.

1

/

8

/

8

".pressure.line

. 9.. Nellcor.Puritan.Bennett

®

.7200,.840

".pressure.line

/

8

".pressure.line

Pressure

Lines

1",

3

16

"

1

8

",

3

16

"

1

8

",

3

16

"

1

8

",

3

16

"

1

8

",

3

16

"

Dry Gas

Line

24"

24"

24"

24"

24"

Qty.

30/cs

30/cs

30/cs

30/cs

30/cs

.11.. Siemens

®

.300/900C

. C. Corrugated.Tube.

. T. PVC.

. Y. Standard.“Y”.

Air

Life

Circuits—Infant Parallel Wire

Code

RT4851-00

RT4851-12

RT4851-18

D=Dual Heat

DS=Dual-

Single Heat

S=Single Limb

Circuit

Length

For Use With

Ventilator

D

D

D

4’

4’

4’

19, 20, 21, 22, 23,

24, 25, 26, 27, 28

19, 20, 21, 22, 23,

24, 25, 26, 27, 28

19, 20, 21, 22, 23,

24, 25, 26, 27, 28

MR850

MR730

MR850

MR730

MR850

MR730

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

Key

Neonatal Ventilators

.19.. Draeger.Babylog.8000,.Evita.

.20.. Infrasonics.Infant.Star.500,.950

.21.. Newport.Breeze

®

.E150

.22.. Sechrist.IV100B,.IV200,.Millenium

.23.. CareFusion.AVEA

®

.ventilator,.Bear.Cub

®

.750.PSV

Parallel Y

Style

Temp Probe

Y

Y

Y

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

.24.. CareFusion.Bird

®

.VIP.ventilator

.25.. Maquet.300A,.Servo.i

.26.. Hamilton.G5

.27.. Biomed.Devices

.28.. Impact.Eagle

Exh

Valve

MDI

Port

Cat. No.

RT4851-00

RT4851-12

RT4851-18

Description

Neonate 4’ heated Circuit

Neonate 4’ heated w/12" remote

Neonate 4’ heated w/18" remote

Qty.

30/cs

30/cs

30/cs

Pressure

Lines

Dry

Gas

Line

(

1

4

)

(

1

4

)

(

1

4

)

Exp

Limb

H

2

O

Trap

Elbow

Omni-Flex

Connector

. D. Dual.Heat.

. Y. Standard.“Y” carefusion.com

29

Circuits Heated

Portable Single-Heated Ventilator Circuits

Designed to be used with Fisher & Paykel Humidifier MR620 and Heater

Wire Adapter 0045-20 (single heated only). Circuits feature standard “Y” style configuration. Applications with Fisher & Paykel Humidifiers MR720 and HC500 require the use of Heater Wire Adapter 900MR539 (single heated only). Humidifier supply line included.

Cat. No.

Size

Circuit

Length

5.5'

For Use With

Ventilators

All listed below

6814-H12

P

6462-H08

A

ww

5.5' All listed below

Key

1.. Aequitron.LP6

,.LP6.Plus

,.LP10

,.LP20

.2.. CareFusion.Bear

®

.33.ventilator

.3.. LIFECARE

®

.brand.PLV

®

-100,.PLV

®

-102

.4.. Nellcor.Puritan.Bennett

®

.2800,.2801

Fisher & Paykel

Humidifiers

MR630

MR730

MR630

MR730

Electrical Adapter

(Pigtail)

0045-20

900MR559

0045-20

900MR559

Omni-Flex

Connector

.A. Adult.

. I. Infant.

.P. Pediatric

Probe Port on “Y”

Temp

Probe Tee

Pressure Port on “Y”

Pressure

Lines

1

8

",

3

16

"

1

8

",

3

16

"

Qty.

20/cs

20/cs

Who is CareFusion?

Our.proven.product.family.of.brands.include.Pyxis

®

.for.medication.and.supply.dispensing,.Alaris

®

.for.infusion,.

AVEA

®

.ventilators,.Jaeger

®

.for.respiratory.diagnostic.instruments,.Air

Life

™.for.respiratory.consumables,.AVA

max

®

.

and.PleurX

®

.for.interventional.procedures,.V..Mueller

®

.and.Snowden-Pencer

®

.surgical.instruments,.ChloraPrep

®

.

skin.antiseptic.and.Nicolet™.neurodiagnostic.devices.

To.make.global.healthcare.better,.we.partner.with.our.customers.to.help.them.improve.medication.management,.

lower.costs.in.procedural.areas,.reduce.risk.of.infection,.advance.the.care.of.ventilated.patients.and.turn.the..

endless.amount.of.data.generated.in.healthcare.into.actionable.information.

30

carefusion.com

MR850 Humidifier Bracket Guide

Draeger Evita 1, 2, Dura, Evita 4, Evita XL, Savina eVent Inspiration

GE Engstrom Carestation, I vent

Hamilton Amadeus, Galileo, Raphael, Veolar

Hamilton G5

Infrasonics Adult Star 2000

Maquet 300A, 900C, Servo i

Newport E 100M, Wave E200, e500 Wave

CareFusion 3100B Oscillator ventilator

PB 840

PB 7200

PB 740, 760

CareFusion LTV

®

ventilator

CareFusion Bear

®

1, 2, 5, 1000 ventilators

CareFusion Bird

®

6400, 8400 ventilators

CareFusion AVEA

®

ventilator

CareFusion VELA

®

, Legacy ventilators

CareFusion TBIRD

®

, EnVe, ReVel

ventilators

CareFusion EnVe, ReVel

ventilators

Respironics Esprit

Respironics V200

CPAP/NPPV Systems

Respironics V60

Respironics Vision, STD 30, Focus

F&P HC254 CPAP

Draeger Carina

CareFusion SiPAP, nCPAP and P driver

Hamilton Aladdin / Arabella

Neonatal Ventilators

PB840

Draeger Babylog 8000

Drager Evita

Infrasonics Infant Star 500, 950

Newport Breeze

®

E150

Sechrist IV100B, IV200, Millenium

CareFusion AVEA

®

ventilator, Bear Cub

®

750 PSV

CareFusion Bird

®

VIP

Hamilton G5

Biomed Devices

Impact Eagle

Maquet 300A, Servo i

Homecare Ventilators

PB Achieva, LP10, LP6

PB 540

Newport HT50

CareFusion Legacy ventilator

CareFusion LTV

®

ventilator

Respironics Trilogy100, PLV102

Bracket and Mounting Arrangement

900MR305

900MR030 and 900MR087

Bracket on ventilator add 900MR087

900MR030 and 900MR087

900MR087

900MR087

900MR303

900MR030 and 900MR087

900MR301

900MR304

900MR081 and 900MR087

900MR167 and 900MR087

900MR030 and 900MR087

900MR083

900MR301

900MR030 and 900MR087

900MR301 and 900MR087

900MR303

900MR030 and 900MR087

900MR030 and 900MR087

900MR087

900MR087

900MR030 & 900MR087

900MR030 & 900HC033

900MR305

900MR030 and 900MR087

900MR030 and 900MR087

900MR304

900MR030 and 900MR087

900MR305

900MR030 and 900MR087

900MR030 and 900MR087

900MR030 and 900MR087

900MR030 and 900MR087

900MR301

900MR087

900MR030 and 900MR087

900MR030 and 900MR087

900MR303

900HC032 (table mount)

900HC032 (table mount)

900HC032 (table mount)

900HC032 (table mount)

900HC032 (table mount)

900HC032 (table mount)

Circuits Heated

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR011

900MR012

900MR012

900MR012

900MR012

900MR012

900MR012

Water Bag Pole

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR290

900MR011

900MR290

900MR290

900MR011

900MR290

900MR290

900MR011

900MR290

900MR290

900MR290

900MR290 carefusion.com

31

Circuits Nonheated

0Y3770 0P1776

0P1775

0Y1777

Adult Dual-Limb Ventilator Circuits, May Be Used

With MR850, MR700 and MR600 Series Heaters

Adult Dual-Limb Circuits Selection Chart

Cat. No.

001790

001793

001794

RC6Y006094

Cat. No.

001790

001793

001794

0P1775

0P1776

0Y1777

0Y1778

0Y1779

0Y3770

RC6Y006094

Bear

®

1, 2, 3 Bear

®

5, 1000 Bird

®

6400 Bird

®

8400

Infrasonics

Adult Star

Puritan Bennett

®

7200

Puritan Bennett

®

MA-1

, MA-2

Siemens Servo

®

300C, 900C

• •

Description

63" segmented inspiratory corrugated tube with water trap in line 24" from ported patient “Y”, segmented expiratory tube has water trap at 24" from “Y” with cascade adapter connector and circuit hanger

Two 6' more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector and tube hanger

Two 6' more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector, tube hanger and

1

/

4

" pressure sensing line

Two 72" more flexible corrugated tubes, ported patient parallel “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb and tube hanger

Two 72" more flexible corrugated tubes, ported patient parallel “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb, tube hanger and 1

/

4

" and 1

/

8

" pressure sensing lines

Two 72" more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb, tube hanger,

/

1

4

" and 1

/

8

" pressure sensing lines and valved tee

Two 72" more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb and tube hanger

Two 72" more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb, tube hanger and 1

/

4

" and 1

/

8

" pressuring sensing lines

72" adult segmented tubing, polypropylene “Y” with temperature and pressure sensing ports with caps, tube holder, hose clips, external exhalation valve, exhalation drive line and expiratory spirometer adapter,

/

1

4

" pressure line and angled, capped temperature port connector on inspiratory limb

Two 72" more flexible corrugated tubes, ported patient “Y” with port plugs, elbow connector, inspiratory connector, angled temp port with plug at distal limb, tube hanger and

1

/

4

" and

1

/

8

" pressuring sensing lines

10/cs

10/cs

10/cs

10/cs

10/cs

20/cs

Qty.

6/cs

6/cs

6/cs

10/cs

Accessories

900MR805

900MR806

900MR869

900MR900

900MR901

900MR569

Heater wire adapter-dual limb, MR850

Heater wire adapter-single limb, MR850

Temperature probe, MR850

Heater wire adapter for dual heated wire circuits for a MR730 with a MR850 circuit

Heater wire adapter for single heated wire circuits for a MR730 with a MR850 circuit

Temperature probe, MR730

32

carefusion.com

Circuit Nonheated

003762

001795

003764

003760

Adult Single-Limb Portable Ventilator Circuits

Adult Single-Limb Circuits Selection Chart

Cat. No.

001797

003760

003762

003764

Cat. No.

001797

003760

003762

003764

Life Products LP4 ™ , LP5 ™

Aequitron LP6 ™ , LP6 Plus ™ , LP10 ™

Description

Same as Circuit 001795, with exhalation supply line adapter

6" patient tube,

1

/

8

" ID pressure line and pressure port cap, polyisoprene diaphragm

6" patient tube, 3

/

16

" ID pressure line, polyisoprene diaphragm

6" patient tube,

1

/

8

" and

1

/

4

" pressure lines, silicone diaphragm

Puritan Bennett ® 2800

LIFECARE ® PLV ® -100, PLV ® -102

Pediatric Dual-Limb Ventilator Circuits For Use

With MR700 Series Heaters

Pediatric Dual-Limb Circuits Selection Chart

Cat. No.

9076-701

Cat. No.

9076-701

Bear Cub

®

Bear

®

BP200

Bird

®

VIP

Sechrist

®

Infrasonics Infant Star

Siemens Servo

®

300C, 900C

Description

4' “Y” with Omni-Flex

connector, 15 mm ID; inspiratory and expiratory self-sealing water traps; chamber outlet probe adapter and humidifier supply line included

Qty.

20/cs

Infant Dual-Limb Ventilator Circuit For Use

With MR700 Series Heaters

This circuit is compatible with Bear Cub

®

, Bear

®

BP200, Bird

®

VIP,

Seachrist

®

, Infrasonics Infant Star and Siemens Servo

®

300C and 900C ventilators. 4” nonheated, with inspiratory and expiratory self-sealing water traps, chamber outlet probe adapter and humidifier supply line included.

Cat. No.

6800-503

Description

Infant dual-limb ventilator circuit

Qty.

30/cs

Qty.

10/cs

15/cs

15/cs

15/cs carefusion.com

33

Circuits NIV/CPAPCircuits

Circuit 003769

Air

Life

Smooth Bore Respiratory Circuits

Our NPPV smooth bore respiratory circuits are designed to provide you with a universal, disposable ventilation circuit for all of your noninvasive patient needs. Contents include:

•.

72” smooth bore tube with an inline attached leak test

•.

Adapter/exhalation port and port cap

•.

96” pressure line tube

•.

Tubing hanger

•.

Hose clips

•.

22 mm connector for nonvented mask applicator

Cat. No.

Circuits

Heated

003769

003770

Description

Without respiratory filter

With respiratory filter

Qty.

10/cs

10/cs

34

carefusion.com

Circuits NIV/CPAPCircuits

RT132 RT219

RT202

Fisher & Paykel Healthcare

Heated NHF/NIV/CPAP Circuits

The use of humidification with noninvasive support is vital for maintaining the natural balance of heat and moisture in the airways.

By heating and humidifying the gas flow to the same level that occurs naturally in the airway, patient tolerance to the therapy is maximized.

RT329

Code

D=Dual Heat

DS=Dual-Single Heat

S=Single Limb

Circuit

Length

For Use

With

Ventilator

Humidifiers

RT202

S 5’

RT219

RT408

RT132

RT324

S

S

S

S

5’

5’

4’

4’

15, 16

Oxygen therapy only

17

17

MR850

MR730

MR850

MR730

MR850

MR730

MR850

MR730

RT329

S 4’

Infant nasal high flow only

MR850

MR730

*.Verify.Bias.Flow.Protocol.is.>.4.lpm.otherwise.use.RT236.or.RT130

Heater Wire

Adapter

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

900MR805

900MR900

Temp Probe

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

900MR869

900MR569

Pressure

Line

Dry

Gas

Line

Pressure

Pop Off

Air

Entrainer

MR290

Key

CPAP/NPPV Systems

.15.. Respironics.V60,.Vision,.STD.30

.16.. Draeger.Carina

.

.17.. CareFusion.SiPAP,.nCPAP.and.P.driver

. D. Dual.Heat.

.DS. Dual-Single.Heat.

. S. Single.Limb.

. P. Parallel.“Y”.

. Y. Standard.“Y”.

Cat. No.

Description

High Performance

RT202

Vent circuit with MR290 single limb heated

Bipap Circuit

RT219

Bipap circuit kit with MR290

Special Circuit

RT408

RT132

Adult oxygen therapy kit with MR290 and air entrainer

Infant continuous flow breathing circuit

RT324

RT329

CPAP / O

2

circuit kit with chamber MR290

Oxygen therapy kit with chamber and pop off valve, MR290 carefusion.com

35

Circuit HeatedWireAdaptersandTemperatureProbes

Humidifier Heater Wire Adapters and Temperature Probes

Fisher & Paykel Healthcare Accessories

For Use with MR850 Humidifier

900MR805

Heater wire adapter, dual-limb

900MR806

900MR869

900MR861

Heater wire adapter, single-limb

Temperature probe, 1.5 m (60”)

Temperature probe, 1.8 m (72”)

For Use with an MR700 Humidifier

900MR569

Temperature probe, 1.5 m (60”)

900MR561

900MR571

Temperature probe, 1.8 m (72”)

Temperature probe, 2.5 m (92”)

For Use on a MR700 Series with a Parallel-Wire Circuit

900MR900

Heater wire adapter, dual-limb

900MR901

Heater wire adapter, single-limb

For Use with a MR700 Series Humidifier with a Serial-Wired Circuit

900MR555

Heater wire adapter, dual-limb

900MR559

Heater wire adapter, single-limb

CareFusion Air

Life

Accessories

For Use with MR700 Series Humidifiers on a Serial-Wired Circuit

0060-23

Heater wire adapter, dual-limb (or 900MR555)

For Use with MR600 Series Humidifiers on a Serial-Wired Circuit

0045-23

Heater wire adapter, dual-limb

0045-20

Heater wire adapter, single-limb

We take care of business, so you can take care of your patients

Our.Respiratory.Resource.Center.is.staffed.by.

respiratory.clinicians.familiar.with.the.challenges.

you.face.

Call.us.at.

800.637.1500

.for.assistance.with:

•. Locating.a.hard-to-find.product

•. .Specifications.for.a.particular.piece..

of.equipment

•. Ventilation.circuit.setup.or.fittings

•. .Help.selecting.the.right.equipment..

for.your.task

Our.job.is.to.help.you.get.back.to.your.job—.

patient.care.

36

carefusion.com

Circuits CircuitAccessories

AirLife

ventilator monitoring adapter circuit 001504

Air

Life

Ventilator Monitoring Adapter Circuit

Our circuit is a flexible, single-patient-use, one-way valving system designed for pulmonary function measurements, such as tidal or minute volume, vital capacity and negative inspiratory force. Circuit comes with a U/Adapt-IT ™ adapter with 15 mm ID base, 6” flextube, two one-way valves, an oxygen tube connector, a 22 mm OD tube adapter and a 22 mm ID/15 mm I.D. adapter.

Cat. No.

001504

Description

Ventilator monitoring adapter circuit

Qty.

50/cs

AirLife

large one-way valve 001802

Air

Life

Large One-Way Valve

Our large one-way valve has a 22 mm OD on both ends. May be used to control directional flow.

Cat. No.

001802

Description

Large one-way valve

Qty.

50/cs

AirLife

one-way valve 001800

Air

Life

One-Way Flutter Valve

Our sensitive one-way, low-resistance flutter valve ensures instant reaction. A 22 mm OD adapter with tapered hose end contains the one-way valve and connects to 22 mm ID tubing. The valve may be removed and reversed as needed. The other end may be attached to any 22 mm ID fitting as needed. Before using, ensure the valve is positioned properly for the direction of flow.

Cat. No.

001800

Circuits

Circuit Accessories

Description

One-way flutter valve

Qty.

50/cs carefusion.com

AirLife

disposable liquid crystal thermometer 001955

Air

Life

Disposable Thermometers

The Air

Life

™ brand TempO

2

I ™ and TempO

2

II ™ systems offer a multitude of thermometer configurations, both liquid column and liquid crystal, designed for all applications and to meet most temperature monitoring situations.

Liquid column thermometers

may be used with most ventilator manifolds and heated aerosol setups. The small tapered end will fit most ported straight adapters and patient “Y” adapters, or its

15 mm OD circumference may be inserted into any standard tee adapter. Readout is provided in both Fahrenheit and Celsius.

Liquid crystal thermometer

produces a direct digital readout that can be placed in the inspirator limb of the patient circuit. It has a

Celsius scale of 20° to 42° with a convenient Fahrenheit conversion table alongside. Temperature is determined by using the three-color readout bands. Green means temperature is exact, tan means it is slightly higher and blue means it is slightly lower.

Cat. No.

Description Qty.

TempO

2

I

Liquid Column Thermometers

001950

Thermometer only

001951

50/cs

With 004086 U/Adapt-It

connector, both arms 22 mm ( 7

/

8

") OD 50/cs

001952

With 004084 U/Adapt-It

connector, one arm 22 mm (

7 and one arm 22 mm (

7

/

8

") ID

/

8

") OD

50/cs

TempO

2

II

Liquid Crystal Thermometer

001955

With two 22 mm OD adapters 50/cs

37

Circuits

CircuitAccessories

AirLife

pediatric connector 3215 AirLife

adult connector 3222

Air

Life

Connectors For Omni-Flex

Systems

Our Air

Life

™ connectors for Omni-Flex ™ systems provide an additional length of tubing for your vertical circuit for increased flexibility and mobility. Connect between a patient’s endotracheal or tracheostomy tube and ventilator circuit wye connection or HME. Connectors expand from 5 to 6.5 cm.

Cat. No.

3215

3222

Description

Pediatric, 15 mm OD x 15mm ID

Adult, 15 mm OD x 22mm OD

Qty.

50/cs

50/cs

Infant neb tee 5900-504 shown with nebulizer

(not included)

Infant neb tee with cap 5903-504

Air

Life

Infant Nebulizer Tees

Our Air

Life

™ infant nebulizer tees can be used to convert an adult nebulizer for infant use. Clean and ready to use.

Cat. No.

5900-504

5903-504

Description

Infant nebulizer tee

Infant nebulizer tee with cap

Qty.

30/cs

30/cs

Water trap 001860

Water traps left 5275P, right 5276

Disposable Water Traps

Our water traps are for use with 22mm tubing.

Cat. No.

5276

5275P

001860

38

Description

4" flexible tube and clamp

Twist valve

Self-sealing

Qty.

50/cs

50/cs

50/cs

AirLife

aerosol “blow-by” circuit 001218

Air

Life

Aerosol “Blow-By” Circuit

Our trach tee circuit has 60” corrugated tubing on one limb and

6” corrugated tubing on the other limb.

Cat. No.

001218

Description

Aerosol “blow-by” circuit

Qty.

50/cs carefusion.com

Circuits CircuitAccessories

MiniSpacer

®

devices left to right: 002091D, 002090D

Metered Dose Inhaler Delivery Systems

For in-line ventilator applications, we offer standard single-spray metered dose inhaler delivery devices and MiniSpacer

®

dual-spray metered dose inhaler devices.

Cat. No.

Description

Standard Single-Spray In-Line Devices

002062

22 mm OD x 22 mm OD

002063

22 mm OD x 22 mm ID

MiniSpacer Dual-Spray In-Line Devices

002090D

22 mm OD x 22 mm OD

002091D

22 mm OD x 22 mm ID

002093D

15 mm OD x 15 mm ID

Qty.

30/cs

30/cs

30/cs

30/cs

30/cs

Metered Dose Inhaler Delivery Systems

For in-line ventilator applications, these MiniSpacer MDI adapters offer dual-spray, cap and a counter advance feature.

Qty.

Cat. No.

Description

MiniSpacer Dual-Spray In-Line Devices with Counter Advance

002094DC

22 mm OD x 22 mm OD

002095DC

002096DC

22 mm OD x 22 mm ID

15 mm OD x 15 mm ID

30/cs

30/cs

30/cs

Valved Tee adapter 002058 shown in use

Air

Life

Valved Tee Adapters

Our Valved Tee adapters make it easy to deliver aerosolized medica- tion to your ventilator patients. Used in conjunction with a nebulizer, the Valved Tee adapter offers a safe and convenient way to introduce medication into the circuit.

Unlike other tee adapters that require time-consuming and potentially hazardous breaks in the system, the Valved Tee adapter becomes a permanent part of the ventilator circuit. Its spring-loaded valve opens and closes the circuit during nebulizer insertion and removal.

Because the adapter maintains a closed system, the risk of condensate being accidently sprayed into the air is greatly reduced. Choose from three sizes for placement at different locations in the circuit. With spring-loaded valve and cap. Include 18 mm base.

Cat. No.

002058

002060

002061

Connection

15 mm ID x 15 mm OD

22 mm ID x 22 mm OD

22 mm ID x 22 mm OD

Qty.

30/cs

30/cs

30/cs carefusion.com

39

Circuits CircuitAccessories

OptiVent

®

in-line MDI spacer HS762

OptiVent

®

In-Line MDI Spacers

(Philips Respironics) These in-line spacers are designed to optimize metered dose inhaler (MDI) drug delivery in ventilator circuits, making a more fine particle drug dose available to the patient. Spacers do not need to be manipulated or expanded for use in a ventilator circuit.

Cat. No.

HS762

HS763

Mfr. No.

HS762-010

HS763-020

Description

22 mm

15 mm

Qty.

10/cs

20/cs

IPPB manifold 001618

Air

Life

IPPB Manifolds

Air

Life

IPPB universal manifolds are compatible with Bird

®

, Puritan

Bennett ® and other commonly used IPPB devices. They feature a silicone diaphragm inside a retainer cap that can be turned to direct exhaled air away from the therapist and patient. All include 39”

(22 mm ID) tubing, two supply lines, 6” (22 mm ID) flextube and mouthpiece.

Cat. No.

001608

001628

Description

With 360° baffled nebulizer for small particle size

With 120° baffled Quick-Neb

right angle nebulizer

Qty.

50/cs

50/cs

If you don’t see what you’re looking for… ask us about it.

If.you.don’t.see.the.product.you’re.looking.for,.

just.pick.up.the.phone.and.ask.your.CareFusion.

sales.representative.to.help.you.find.the.item.

you.need..Or,.call.our.Respiratory.Resource.

Center.at.

800.637.1500.

40

carefusion.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents