XSNet S4104SW/S4108SW
Manual
Important: Note that XSNet Series manuals may cover multiple models. To establish if a particular feature or specification in this manual applies to the unit at hand, consult the datasheet of the given model.
Note: The EU Declaration of Conformity for this product can be found at www.siqura.com/support-files.
Quick Start Guide
This quick start guide describes how to install and use the Industrial Managed
Ethernet Switch. This is the switch of choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
1
XSNet S4104SW/S4108SW
Power 1
Power 2
Power 3
Steady Power on
10/100Base-TX, 100Base SFP
LINK/ACT
Steady A valid network connection established
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
100 Steady Connection at 100Mbps speed
1000Base SFP
LINK/ACT
Steady A valid network connection established
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
1000 Steady Connection at 1000Mbps speed
Power Input Assignment
Power2
Power1
+
-
+
-
12-48VDC
Power Ground
12-48VDC
Power Ground
Terminal
Block
Earth Ground
Relay Output Rating 1A @ 24VDC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
The relay contact closes if Power1 and Power2 are both failed but Power3 on.
The relay contact closes if Power3 is failed but
Power1 and Power2 are both on.
Functional Description
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.
Manageable via SNMP, Web-based, Telnet, and RS-232 console port.
Supports Command Line Interface in RS-232 console.
Supports 802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
10/100/1000Mbps, full/half-duplex. Auto MDI/MDIX.
The S4104SW is equipped with 2x 100Base-FX SFP slots.
The S4108SW is equipped with 2x 1000Base-FX SFP slots.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
2
XSNet S4104SW/S4108SW
Alarms for power and port link failure by relay output.
Power Supply: Redundant DC Terminal Block power inputs or 12VDC
DC JACK with 100-240VAC external power supply.
Operating voltage and Max. current consumption: 0.92A @ 12VDC,
0.46A @ 24VDC, 0.23A @ 48VDC. Power consumption: 11W Max.
-10°C to 60°C (14°F to 140°F) operating temperature range. Tested for functional operation @ -20°C to 70°C (-4°F to 158°F).
Supports DIN-Rail and Panel Mounting installation.
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application. Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below:
Logon to Exec Mode (View Mode):
At the “switch_a login: ” prompt just type in “root” and press <Enter> to logon to Exec Mode (or View Mode). And the “switch_a>” prompt will show on the screen.
3
XSNet S4104SW/S4108SW
Logon to Privileged Exec Mode (Enable Mode):
At the “switch_a>” prompt just type in “enable” and press <Enter> to logon to Privileged Exec Mode (or Enable Mode). And the “switch_a#” prompt will show on the screen.
Logon to Configure Mode (Configure Terminal Mode):
At the “switch_a#” prompt just type in “configure terminal” and press
<Enter> to logon to Configure Mode (or Configure Terminal Mode). And the “switch_a(config)#” prompt will show on the screen.
Set new IP address and subnet mask for Switch:
At the “switch_a(config)#” prompt just type in “interface vlan1.1” and press <Enter> to logon to vlan 1 (vlan1.1 means vlan 1). And the
“switch_a(config-if)#” prompt will show on the screen.
Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0,
16:255.255.0.0, or 24: 255.255.255.0.
For example, At the “switch_a(config-if)#” prompt just type in “ip address
192.168.1.10/24” and press <Enter> to set new IP address
(192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.
4
XSNet S4104SW/S4108SW
Web Configuration
Login the switch:
Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below:
Enter the factory default login ID: root.
Enter the factory default password (no password).
Then click on the “Login” button to log on to the switch.
5
XSNet S4104SW/S4108SW
6
advertisement
Related manuals
advertisement
Table of contents
- 1 Manual
- 1 Quick Start Guide
- 1 Physical Description
- 1 The Port Status LEDs and Power Inputs
- 2 Functional Description
- 3 Console Configuration
- 5 Web Configuration
- 7 Preface
- 8 Table of Contents
- 10 Product Overview
- 10 Industrial Managed Ethernet Switch
- 10 Package Contents
- 11 Product Highlights
- 11 Basic Features
- 11 Management Support
- 11 VLAN
- 11 TRUNKING
- 11 PORT-SECURITY
- 11 PORT-MIRRORING
- 12 QOS (IEEE802.1p Quality of Service)
- 12 INTERNETWORKING PROTOCOLS
- 12 NETWORK MANAGEMENT METHODS
- 13 Front Panel Display
- 13 This LED comes on when the switch is properly connected to power and turned on.
- 13 The LEDs are located on the front panel, displaying status for each respective port. Please refer to the following table for more details.
- 14 Physical Ports
- 14 CONNECTIVITY
- 14 MODE SELECTION
- 15 Switch Management
- 15 Web-based browser interface
- 15 Administration console via RS-232 serial port (CLI)
- 15 External SNMP-based network management application
- 16 Installation
- 16 Selecting a Site for the Switch
- 17 Connecting to Power
- 17 12VDC DC Jack
- 17 Redundant DC Terminal Block Power Inputs
- 17 Alarms for Power Failure
- 18 Connecting to Your Network
- 18 Cable Type & Length
- 20 Cabling
- 21 Switch Management
- 21 Management Access Overview
- 22 Administration Console (CLI)
- 22 Direct Access
- 22 [DEFAULT PARAMETERS]
- 23 Web Management
- 23 SNMP-Based Network Management
- 24 Protocols
- 24 VIRTUAL TERMINAL PROTOCOLS, SUCH AS TELNET
- 24 A virtual terminal protocol is a software program, such as Telnet, that allows you to establish a management session from a Macintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.
- 24 SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
- 24 SNMP is the standard management protocol for multivendor IP networks. SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol (UDP), offering a connectionless-mode service.
- 24 Management Architecture
- 25 SNMP & RMON Management
- 25 Overview
- 25 - The RMON probe is an intelligent device or software agent that continually collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a management workstation on request or when a pre-defined threshold is reached.
- 25 - The management workstation collects the statistics that the RMON probe gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.
- 26 SNMP Agent and MIB-2 (RFC 1213)
- 26 - Retrieving MIB counters from various layers of software modules according to the SNMP GET/GET NEXT frame messages.
- 26 - Setting MIB variables according to the SNMP SET frame message.
- 26 - Generating an SNMP TRAP frame message to the Network Management Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:
- 26 WARM START
- 26 COLD START
- 26 LINK UP
- 26 LINK DOWN
- 26 AUTHENTICATION FAILURE
- 26 RISING ALARM
- 26 FALLING ALARM
- 26 TOPOLOGY ALARM
- 26 RMON MIB (RFC 2819) and Bridge MIB (RFC 1493)
- 27 RMON Groups Supported
- 27 - RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.
- 27 - RMON History Group – gathers and stores periodic statistical samples from the previous Statistics Group.
- 27 - RMON Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable. An alarm can be associated with Low Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a threshold, falls below a threshold, or exceeds or falls below a threshold.
- 27 - RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.
- 27 Bridge Groups Supported
- 27 - The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.
- 27 - The dot1dStp Group – contains objects that denote the bridge’s state with respect to the Spanning Tree Protocol. If a node does not implement the Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only, source route, or SRT bridge that implements the Spanning Tree Protocol.
- 27 - The dot1dTp Group – contains objects that describe the entity’s transparent bridging status. This group is applicable to transparent operation only and SRT bridges.
- 27 - The dot1dStatic Group – contains objects that describe the entity’s destination-address filtering status. This group is applicable to any type of bridge which performs destination-address filtering.
- 28 Web-Based Browser Management
- 28 Logging on to the switch
- 28 SWITCH IP ADDRESS
- 29 LOGIN
- 29 Enter the factory default login ID: root.
- 29 PASSWORD
- 29 Enter the factory default password (no password).
- 30 Understanding the Browser Interface
- 30 SYSTEM
- 30 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Alarm Setting, Reboot, Logout
- 30 PORT
- 30 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities, Port Security
- 30 SWITCHING
- 30 Bridging, Static MAC Entry, Port Mirroring
- 31 TRUNKING
- 31 Port Trunking, LACP Trunking
- 31 STP / RING
- 31 VLAN
- 31 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 31 QOS
- 31 Global Configuration, 802.1p Priority, DSCP
- 31 SNMP
- 31 802.1X
- 31 OTHER PROTOCOLS
- 32 System
- 32 System Information
- 36 ARP Table
- 37 Route Table
- 44 Alarm Setting
- 47 Port
- 53 Switching
- 56 Trunking
- 58 STP / Ring
- 68 Chain Setting
- 69 VLAN
- 76 QoS
- 79 SNMP
- 84 802.1x
- 87 Port Authentication
- 88 Other Protocols
- 97 Command Line Console Management
- 97 Administration Console
- 98 Exec Mode (View Mode)
- 102 Privileged Exec Mode (Enable Mode)
- 107 Configure Mode (Configure Terminal Mode)
- 111 User Interface Configuration
- 111 Http Server, Http Secure-Server, Telnet, SSH
- 113 System
- 113 System Information, System Name/Password, IP Address, ARP Table, Route Table, Save Configuration, Firmware Upgrade, Alarm Setting, Reboot, Logout
- 124 Port
- 124 Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan Activities, Port Security
- 131 Switching
- 131 Bridging, Static MAC Entry, Port Mirroring
- 136 Trunking
- 136 Port Trunking, LACP Trunking
- 141 STP / Ring
- 141 Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP Port Setting, Ring Setting, Chain Setting
- 155 Chain Setting
- 157 VLAN
- 157 VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
- 163 QoS
- 166 SNMP
- 173 802.1x
- 178 Other Protocols
- 196 Specifications
- 196 LED Indicators
- 196 Operating
- 196 Temperature
- 198 Appendix A
- 199 Appendix B