XSNet S4104SW/S4108SW

Manual

Important: Note that XSNet Series manuals may cover multiple models. To establish if a particular feature or specification in this manual applies to the unit at hand, consult the datasheet of the given model.

Note: The EU Declaration of Conformity for this product can be found at www.siqura.com/support-files.

Quick Start Guide

This quick start guide describes how to install and use the Industrial Managed

Ethernet Switch. This is the switch of choice for harsh environments constrained by space.

Physical Description

The Port Status LEDs and Power Inputs

1

XSNet S4104SW/S4108SW

Power 1

Power 2

Power 3

Steady Power on

10/100Base-TX, 100Base SFP

LINK/ACT

Steady A valid network connection established

Flashing

Transmitting or receiving data

ACT stands for ACTIVITY

100 Steady Connection at 100Mbps speed

1000Base SFP

LINK/ACT

Steady A valid network connection established

Flashing

Transmitting or receiving data

ACT stands for ACTIVITY

1000 Steady Connection at 1000Mbps speed

Power Input Assignment

Power2

Power1

12-48VDC

Power Ground

12-48VDC

Power Ground

Terminal

Block

Earth Ground

Relay Output Rating 1A @ 24VDC

Relay Alarm Assignment

FAULT

*Warning signal disable for following:

The relay contact closes if Power1 and Power2 are both failed but Power3 on.

The relay contact closes if Power3 is failed but

Power1 and Power2 are both on.

Functional Description

 Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.

 Manageable via SNMP, Web-based, Telnet, and RS-232 console port.

 Supports Command Line Interface in RS-232 console.

 Supports 802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:

10/100/1000Mbps, full/half-duplex. Auto MDI/MDIX.

 The S4104SW is equipped with 2x 100Base-FX SFP slots.

 The S4108SW is equipped with 2x 1000Base-FX SFP slots.

 Supports 8192 MAC addresses. Provides 2M bits memory buffer.

2

XSNet S4104SW/S4108SW

 Alarms for power and port link failure by relay output.

 Power Supply: Redundant DC Terminal Block power inputs or 12VDC

DC JACK with 100-240VAC external power supply.

 Operating voltage and Max. current consumption: 0.92A @ 12VDC,

0.46A @ 24VDC, 0.23A @ 48VDC. Power consumption: 11W Max.

 -10°C to 60°C (14°F to 140°F) operating temperature range. Tested for functional operation @ -20°C to 70°C (-4°F to 158°F).

 Supports DIN-Rail and Panel Mounting installation.

Console Configuration

 Connect to the switch console:

Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application. Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.

 Configuration settings of the terminal-emulation program:

Baud rate: 115,200bps

Data bits: 8

Parity: none

Stop bit: 1

Flow control: none

 Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below:

 Logon to Exec Mode (View Mode):

At the “switch_a login: ” prompt just type in “root” and press <Enter> to logon to Exec Mode (or View Mode). And the “switch_a>” prompt will show on the screen.

3

XSNet S4104SW/S4108SW

 Logon to Privileged Exec Mode (Enable Mode):

At the “switch_a>” prompt just type in “enable” and press <Enter> to logon to Privileged Exec Mode (or Enable Mode). And the “switch_a#” prompt will show on the screen.

 Logon to Configure Mode (Configure Terminal Mode):

At the “switch_a#” prompt just type in “configure terminal” and press

<Enter> to logon to Configure Mode (or Configure Terminal Mode). And the “switch_a(config)#” prompt will show on the screen.

 Set new IP address and subnet mask for Switch:

At the “switch_a(config)#” prompt just type in “interface vlan1.1” and press <Enter> to logon to vlan 1 (vlan1.1 means vlan 1). And the

“switch_a(config-if)#” prompt will show on the screen.

Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0,

16:255.255.0.0, or 24: 255.255.255.0.

For example, At the “switch_a(config-if)#” prompt just type in “ip address

192.168.1.10/24” and press <Enter> to set new IP address

(192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.

4

XSNet S4104SW/S4108SW

Web Configuration

 Login the switch:

Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below:

 Enter the factory default login ID: root.

Enter the factory default password (no password).

Then click on the “Login” button to log on to the switch.

5

XSNet S4104SW/S4108SW

6